{"product_id":"ge-ic200alg320d-versamax-analog-output-module","title":"GE IC200ALG320D VersaMax Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 100% Brand New GE IC200ALG320D provides four independent 4-20mA analog output channels for the VersaMax I\/O system. It converts digital control values from the CPU into precise current signals for field actuators. The module features 12-bit resolution and a 0.3ms update rate for high-speed closed-loop control applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC200ALG320D\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE VersaMax\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 (Independent)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA (Fixed Current Loop)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-Bit (4 µA \/ 8 Counts)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.3% Typical, ±0.5% Max (at 25°C)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 ms (Maximum, all channels)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18-30 VDC (160 mA max load)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 VDC @ 50 mA\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 VAC (Field to Backplane)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 x 11.0 x 6.68 cm\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFLD PWR (Field Power), OK (Backplane Power)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Control Loop Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.3ms update rate ensures immediate command execution. This minimizes dead time in fast-acting closed-loop systems like flow or pressure control, maintaining process stability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndependent Channel Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel utilizes a dedicated Digital-to-Analog Converter (DAC). A fault on one output does not disrupt the operation of the remaining three channels, ensuring partial process continuity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZero Downtime Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports Removal and Insertion Under Power (RIUP). Technicians replace a faulty unit without shutting down the process, maintaining continuous production.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Power Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual LEDs provide immediate status. The \"FLD PWR\" LED confirms external loop power, while the \"OK\" LED verifies backplane logic power, eliminating guesswork during troubleshooting.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module requires an external 18-30 VDC power supply to drive the 4-20mA loops. It does not source power from the backplane for the field outputs.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure 0-20mA or voltage outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200ALG320D is factory-hardware configured for 4-20mA current output only. It does not support 0-20mA or 0-10V ranges.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal base is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt mounts on standard VersaMax terminal bases (e.g., IC200TBM002 or IC200TBS002). Ensure the terminal base connects to the external 24VDC supply.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \"-D\" suffix interchangeable with \"-A\" or \"-B\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC200ALG320D functions as a direct electrical and mechanical replacement for earlier revisions (IC200ALG320, IC200ALG320A, IC200ALG320B). The suffix denotes specific manufacturing updates or component changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52373366047032,"sku":"IC200ALG320D","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG320.jpg?v=1778812152","url":"https:\/\/www.automodulexpert.com\/az\/products\/ge-ic200alg320d-versamax-analog-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}