{"product_id":"aai135-s50-analog-input-module-yokogawa","title":"AAI135-S50 Analog Input Module Yokogawa","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI135-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol system. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 fully isolated 4–20 mA input channels\u003c\/strong\u003e, ensuring reliable signal acquisition while protecting the system from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical noise and ground loop interference\u003c\/strong\u003e.\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especification denotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard basic type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintended for installation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-hazardous (safe) areas\u003c\/strong\u003e, making it well suited for high-reliability process automation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels, fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e360 mA @ 5 V DC; 450 mA @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Options\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminals, MIL cables, or KS1 cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNon-explosion protected (Type 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Classification\u003c\/td\u003e\n\u003ctd\u003eBasic functional type (Type 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e33 × 130 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe AAI135-S50 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedium-density monitoring applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow measurement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater treatment facilities\u003c\/strong\u003e, and other process industries.\u003cbr\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efully isolated architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emakes it particularly effective for installations with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elong cable runs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor electrically noisy environments where maintaining signal integrity is critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the AAI135-S50 differ from higher-density AAI135 variants?\u003c\/strong\u003e\u003cbr\u003eA: While some AAI135 models offer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 input channels\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 fully isolated channels\u003c\/strong\u003e, prioritizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal separation and protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eover channel density.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field wiring options are supported?\u003c\/strong\u003e\u003cbr\u003eA: The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure clamp terminal blocks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor direct wiring, as well as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMIL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS1 cable interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor fast, prewired connections to external terminal boards.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51664574415160,"sku":"AAI135-S50","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI135-S501.jpg?v=1769480379","url":"https:\/\/www.automodulexpert.com\/bg\/products\/aai135-s50-analog-input-module-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}