{"product_id":"ale111-s50-s1-yokogawa-ethernet-communication-module","title":"ALE111-S50 S1 Yokogawa Ethernet Communication Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALE111-S50 (S1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Ethernet communication interface designed for the Yokogawa Electric Corporation CENTUM VP and legacy CENTUM CS 3000 \/ CENTUM CS 1000 control architectures.\u003c\/p\u003e\n\u003cp\u003eThis module functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esubsystem communication gateway\u003c\/strong\u003e, allowing the DCS to exchange process and diagnostic data with external intelligent devices such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePLC controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas chromatographs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntelligent electronic devices (IEDs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThird-party automation subsystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ALE111-S50 S1 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard Ethernet communication variant\u003c\/strong\u003e, designed for high-speed data exchange, low latency control messaging, and stable 24\/7 operation in general industrial environments. It occupies a single FCS I\/O slot and is optimized for low power consumption with efficient thermal dissipation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Code\u003c\/td\u003e\n\u003ctd\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Revision\u003c\/td\u003e\n\u003ctd\u003eS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eEthernet subsystem communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e10BASE-T \/ 100BASE-TX Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10 \/ 100 Mbps auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Connections\u003c\/td\u003e\n\u003ctd\u003eMultiple TCP\/IP and UDP sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CS 3000 \/ CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in FCS\/FCN\/FCU rack module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-power system bus operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix Code Meaning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Standard hardware type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Non-explosion-proof specification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Basic functional configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe ALE111-S50 S1 is widely used in plant-wide integration architectures where the DCS must communicate with external automation systems. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFood and beverage process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLaboratory and analytical instrumentation integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module is especially suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata acquisition and supervisory communication tasks\u003c\/strong\u003e, enabling Yokogawa DCS systems to act as central supervisory controllers across heterogeneous automation networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ALE111-S50 S1 support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. The module can be installed in redundant pairs within compatible racks to ensure communication continuity. If one module fails, the backup module maintains network connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“5” suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates non-explosion-protected hardware. Installation should be limited to safe areas or protective enclosures compliant with facility hazardous zone classifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eThe module supports standard Ethernet-based communication protocols such as TCP\/IP and UDP for subsystem integration and data exchange.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51818443505976,"sku":"ALE111-S50 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ALE111-S50_S1.jpg?v=1771911404","url":"https:\/\/www.automodulexpert.com\/bg\/products\/ale111-s50-s1-yokogawa-ethernet-communication-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}