{"product_id":"cp471-01-s2-yokogawa-centum-vp-cpu-processor-module","title":"CP471-01 S2 Yokogawa CENTUM VP CPU Processor Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP471-01 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral processing unit (CPU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. Serving as the primary logic engine within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Stations (FCS)\u003c\/strong\u003e, it delivers high-speed control execution and reliable data handling for complex, mission-critical processes.\u003c\/p\u003e\n\u003cp\u003eAs the direct successor to the CP461 series, the CP471-01 S2 offers significantly improved processing efficiency and is optimized for modern automation requirements. It is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV30 and AFV40 Field Control Units\u003c\/strong\u003e, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enative dual-redundant (hot-standby) configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure high system availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP471-01 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor Module (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP R6.01 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (Hot-standby)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication \u0026amp; System Integration\u003c\/h2\u003e\n\u003cp\u003eThe CP471-01 S2 is deployed in environments where continuous control and fault tolerance are mandatory, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas refining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and utility plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration Notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTypically paired with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEC401 ESB Bus Coupler (Style S3 or later)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor extended I\/O communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade Path:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOfficial replacement for legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECC memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor single-bit error detection and correction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComprehensive self-diagnostic functions for hardware and software integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan a CP461 and CP471-01 S2 be used together in a redundant pair?\u003c\/strong\u003e\u003cbr\u003eNo. Dual-redundant configurations require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo identical CPU modules\u003c\/strong\u003e. Mixing CP461 and CP471-01 S2 is not supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software version is required?\u003c\/strong\u003e\u003cbr\u003eCENTUM VP\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR6.01 or later\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis required. Additional patches may be necessary depending on the specific R6 sub-version.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51638604202296,"sku":"CP471-01 S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CP471-01.jpg?v=1768982012","url":"https:\/\/www.automodulexpert.com\/bg\/products\/cp471-01-s2-yokogawa-centum-vp-cpu-processor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}