{"product_id":"cpu-module-yokogawa-nfcp501-w05-s1-centum-vp-control","title":"CPU Module Yokogawa NFCP501-W05 S1 CENTUM VP Control","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFCP501-W05 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Field Control Station (FCS) processor module designed for the Yokogawa Electric Corporation\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrated production control system. It serves as the primary computational engine responsible for executing complex regulatory control algorithms and sequence logic in real time.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“W05”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant typically designates a wide-temperature or specialized environmental hardware specification, ensuring stable performance in demanding industrial conditions. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“S1”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates the hardware revision level, incorporating important stability and compatibility updates for the CENTUM platform.\u003c\/p\u003e\n\u003cp\u003eWith advanced memory protection and dual-redundancy capability, the NFCP501-W05 S1 ensures high system availability, seamless failover, and deterministic control performance in mission-critical applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Code\u003c\/td\u003e\n\u003ctd\u003eNFCP501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix \/ Revision\u003c\/td\u003e\n\u003ctd\u003e-W05 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eHigh-speed real-time control processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Control Cycle\u003c\/td\u003e\n\u003ctd\u003e50 ms (load dependent, configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eECC (Error Correction Code) supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant pairing supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe NFCP501-W05 S1 is primarily installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV50D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV50S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField Control Units (FCU). It is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale refinery operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and chemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-availability PID and sequence control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts Vnet\/IP compatibility ensures seamless integration into plant-wide control networks while maintaining deterministic execution performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Maintenance FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an NFCP501 module while the system is online?\u003c\/strong\u003e\u003cbr\u003eIf the Field Control Station is configured in a dual-redundant setup, the standby NFCP501-W05 S1 module can be replaced while the primary unit continues operation. After installation, database synchronization (“database copy”) must be executed to ensure proper redundancy alignment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between NFCP501 and NFCP100?\u003c\/strong\u003e\u003cbr\u003eThe NFCP501 is optimized for Vnet\/IP-based architectures and offers significantly higher processing capacity and memory performance compared to the legacy NFCP100 series used in earlier CENTUM CS 3000 systems.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51799343071544,"sku":"NFCP501-W05\/S01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFCP501-W05S01.jpg?v=1771037170","url":"https:\/\/www.automodulexpert.com\/bg\/products\/cpu-module-yokogawa-nfcp501-w05-s1-centum-vp-control","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}