{"product_id":"digital-input-module-yokogawa-adv142-p03","title":"Digital Input Module Yokogawa ADV142-P03","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV142-P03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel high-voltage digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. It is intended to interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200–240 V AC field signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommonly found in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor control centers, industrial switchgear, and power distribution networks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP03 suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-compliant protection against corrosive gases\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand an extended operating temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–20 to 70 °C\u003c\/strong\u003e, making the module suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh industrial environments\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust electrical isolation (2 kV AC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field inputs and system logic, ensuring high reliability and safety.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Suffix\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV142-P03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 isolated AC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–240 V AC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eON Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160–264 V AC (Peak: 226–373 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOFF Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 40 V AC (Peak ≤ 56 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2 mA per channel @ 240 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.3 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal-to-System Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Between Commons\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.35 kV AC, 1 min (8 channels per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 160 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePushbutton Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 2.5 Hz, min ON 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 (corrosive gas protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Input Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles 200–240 V AC signals safely for industrial power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePushbutton Edge Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCaptures manual input cycles for operator intervention, with min ON time 200 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Grouping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannels are divided into sets of 8, providing isolated common returns for multiple AC circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Environmental Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating and extended temperature range for corrosive and harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV AC isolation between inputs and system logic, ensuring reliable operation in noisy or high-voltage environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Control Centers (MCCs):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring auxiliary contact signals from circuit breakers or starters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution Networks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapturing high-voltage switch and breaker statuses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy Machinery Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing with high-voltage AC limit switches or safety interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Process Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRefineries or chemical plants requiring G3-compliant protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does ADV142 differ from ADV141?\u003c\/strong\u003e\u003cbr\u003eA: ADV141 handles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100–120 V AC\u003c\/strong\u003e, while ADV142 is rated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200–240 V AC\u003c\/strong\u003e. Using the wrong voltage can permanently damage the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the response time 160 ms, slower than DC modules?\u003c\/strong\u003e\u003cbr\u003eA: AC inputs require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erectification and filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto distinguish true ON\/OFF states across a 50\/60 Hz sine wave, which naturally slows response compared to 24 V DC modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a specific terminal block?\u003c\/strong\u003e\u003cbr\u003eA: Yes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage rated pressure-clamp or compatible cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare required to maintain creepage distances and operator safety.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51688033124664,"sku":"ADV142-P03","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV1421.jpg?v=1770001408","url":"https:\/\/www.automodulexpert.com\/bg\/products\/digital-input-module-yokogawa-adv142-p03","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}