{"product_id":"isolated-analog-input-module-yokogawa-aai135-s50-ccc01","title":"Isolated Analog Input Module Yokogawa AAI135-S50\/CCC01","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI135-S50\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system. It interfaces with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA field transmitters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight fully isolated input channels\u003c\/strong\u003e, ensuring that ground loops, noise, or voltage surges on one loop do not affect other channels or the system backplane.\u003c\/p\u003e\n\u003cp\u003eThis variant includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC01 option\u003c\/strong\u003e, a protective\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econnector cover\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat enhances mechanical stability and environmental protection at the wiring interface. The AAI135-S50\/CCC01 is widely selected for applications where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal integrity, fault containment, and long-term reliability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI135-S50\/CCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully isolated (channel-to-channel, channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC (inputs ↔ system, channel ↔ channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Ω (power ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCCC01 – connector cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS50 (standard analog, non-HART, non-explosion protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.35 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI135-S50\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis well suited for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrically noisy or geographically dispersed installations\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMetal and mineral processing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efully isolated architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emakes it especially effective for long cable runs and mixed grounding environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AAI135-S50\/CCC01 support HART communication?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix identifies a standard analog version without HART. For HART diagnostics and digital communication, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eH50 or H53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariants should be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the CCC01 option?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCC01 connector cover\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides added mechanical protection for the wiring interface, helping prevent accidental disconnection and improving durability in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edusty or high-vibration environments\u003c\/strong\u003e.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51676601614648,"sku":"AAI135-S50\/CCC01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI135-S50CCC01.jpg?v=1769738626","url":"https:\/\/www.automodulexpert.com\/bg\/products\/isolated-analog-input-module-yokogawa-aai135-s50-ccc01","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}