{"product_id":"triconex-4000094-346-tmr-safety-control-module","title":"Triconex 4000094-346 TMR Safety Control Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 4000094-346 Control Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance processing component designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex Triple Modular Redundant (TMR) Safety Instrumented Systems (SIS)\u003c\/strong\u003e. It delivers the logic execution and processing capability required for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex, high-demand safety applications\u003c\/strong\u003e, utilizing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-out-of-3 (2oo3) voting architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate single points of failure and maintain continuous safe operation under fault conditions.\u003c\/p\u003e\n\u003cp\u003eOptimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC industrial environments\u003c\/strong\u003e, the 4000094-346 is widely deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3-certified safety loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmergency Shutdown (ESD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBurner Management Systems (BMS)\u003c\/strong\u003e. Its hardened hardware design provides strong resistance to electromagnetic interference and thermal stress, ensuring reliable real-time monitoring and control in harsh industrial settings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Tolerance\u003c\/strong\u003e\u003cbr\u003eImplements\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR with 2oo3 hardware voting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto preserve safety integrity and availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3-Certified Architecture\u003c\/strong\u003e\u003cbr\u003eCompliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61508\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements for high-hazard industrial applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Reliability\u003c\/strong\u003e\u003cbr\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith enhanced electrical isolation and thermal stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless System Integration\u003c\/strong\u003e\u003cbr\u003eFits standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand supports high-availability, hot-swap-capable architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Safety Processing\u003c\/strong\u003e\u003cbr\u003eOptimized for continuous monitoring and control of critical process variables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000094-346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Control \/ Processing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundant (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoting Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2oo3 Hardware Voting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL3 Capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess Safety and Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Instrumented Systems (SIS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Shutdown (ESD) Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBurner Management Systems (BMS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-Hazard Process Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; Gas, Power Generation, and Chemical Industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRICONEX","offers":[{"title":"Default Title","offer_id":51582533468472,"sku":"4000094-346","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/3625C1-J1.jpg?v=1767491690","url":"https:\/\/www.automodulexpert.com\/bg\/products\/triconex-4000094-346-tmr-safety-control-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}