{"product_id":"v-net-coupler-unit-yokogawa-centum-vp-aip504-50","title":"V-NET Coupler Unit Yokogawa CENTUM VP AIP504-50","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP504-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-NET coupler module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP and CS 3000 DCS platforms\u003c\/strong\u003e. It functions as a communication bridge between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand field-side devices, enabling deterministic, high-speed data exchange across the V-NET control network.\u003c\/p\u003e\n\u003cp\u003eEngineered for high-availability applications, the module incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust galvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect the DCS backplane from electrical disturbances. Its scalable architecture supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 connected nodes\u003c\/strong\u003e, making it suitable for distributed process control environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2–28.8 V DC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.8 A @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eV-NET (Yokogawa proprietary control network)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Node Support\u003c\/td\u003e\n\u003ctd\u003e32 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e0.5 mm P-P (5–14 Hz); 3.9 m\/s² (14–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack or panel mount (AFF500 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e220 × 160 × 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Enables module replacement without shutting down the control loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– LED indicators for power, run status, and communication health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Protects system backplane from field-side surges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Humidity Tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Supports up to 95% non-condensing humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Supports up to 32 V-NET connected nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM VP distributed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM CS 3000 process automation platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AIP504-50 require specific software configuration?\u003c\/strong\u003e\u003cbr\u003eA: No. It is automatically recognized within the Yokogawa System View configuration environment as part of the I\/O bus definition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit compatible with older CENTUM CS systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It maintains backward compatibility with the AFF500 Series architecture used in both CENTUM VP and CS 3000 platforms.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51789455622456,"sku":"AIP504-50","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIP504-502.jpg?v=1770860833","url":"https:\/\/www.automodulexpert.com\/bg\/products\/v-net-coupler-unit-yokogawa-centum-vp-aip504-50","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}