{"product_id":"yokogawa-aai135-s00-isolated-analog-input-module","title":"Yokogawa AAI135-S00 Isolated Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI135-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries control systems. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 fully isolated 4–20 mA input channels\u003c\/strong\u003e, ensuring accurate signal acquisition while protecting the system from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical noise and ground loops\u003c\/strong\u003e.\u003cbr\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebasic type (S00)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is intended for standard installations where reliable analog signal monitoring is the primary requirement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels, fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage isolation between channels and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Cycle\u003c\/td\u003e\n\u003ctd\u003eHigh-speed sampling suitable for real-time control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eStandard S-type, Basic (0) configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (via backplane or external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e102 × 279 × 254 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe AAI135-S00 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedium-density process monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater treatment\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHVAC control\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanufacturing lines\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efully isolated architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein electrically noisy environments with heavy machinery or long cable runs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with HART communication?\u003c\/strong\u003e\u003cbr\u003eA: No. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant handles analog 4–20 mA signals only. For HART-enabled applications, consider the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI135-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module accept 1–5 V DC inputs?\u003c\/strong\u003e\u003cbr\u003eA: Indirectly. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshunt resistor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross the input terminals can allow voltage measurement, but dedicated voltage input modules are recommended for high-accuracy voltage applications.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51664586113336,"sku":"AAI135-S00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI135-S00.jpg?v=1769478347","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-aai135-s00-isolated-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}