{"product_id":"yokogawa-adv141-p53-digital-input-module","title":"Yokogawa ADV141-P53 Digital Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV141-P53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel high-voltage digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. It is engineered to acquire\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100–120 V AC field signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom devices such as heavy-duty limit switches, motor contacts, and industrial power circuits.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e, the ADV141-P53 ensures that electrical noise or faults on one channel do not affect other channels or the system logic. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-P53 configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadds an integrated pushbutton for local interaction (P), excludes a status display (5), and includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-compliant protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(3) for corrosive environments and extended temperature operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-P53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual channel-to-channel; 2 kV AC (signal-to-system, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eIndustrial Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubstation Monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Acquiring 110 V AC status signals from circuit breakers and protective relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy Machinery Feedback\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Interfacing with high-voltage AC limit switches on conveyors, cranes, or pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUtilities \u0026amp; Power Generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Monitoring auxiliary power states and AC actuators in thermal or hydroelectric plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Reliable operation in chemical plants or wastewater facilities with corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the ADV141-P53 accept DC inputs?\u003c\/strong\u003e\u003cbr\u003eA: No. This module is designed exclusively for 100–120 V AC signals. Use the ADV151 series for 24 V DC inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the -P53 suffix indicate?\u003c\/strong\u003e\u003cbr\u003eA: “P” = pushbutton input; “5” = no LED status display; “3” = G3-rated corrosion protection and extended temperature range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used without a terminal block?\u003c\/strong\u003e\u003cbr\u003eA: Typically, it connects via a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure-clamp terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor dedicated AKB-series cables for safe field wiring integration.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51687966507320,"sku":"ADV141-P53","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV1412.jpg?v=1770001408","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-adv141-p53-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}