{"product_id":"yokogawa-adv151-p63-d5a00-digital-input-module","title":"Yokogawa ADV151-P63\/D5A00 Digital Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-P63\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-channel digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. Engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erugged and harsh environments\u003c\/strong\u003e, it features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-compliant conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand an extended temperature rating to withstand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecorrosive atmospheres and thermal fluctuations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD5A00 interface adapter\u003c\/strong\u003e, the module connects via a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle KS cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor all 32 channels, simplifying cabinet wiring. It supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esink and source input logic\u003c\/strong\u003e, enabling integration with a variety of field devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, proximity sensors, and pushbuttons\u003c\/strong\u003e. Integrated status displays and pushbutton input allow for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocal diagnostics and manual interaction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edirectly at the rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV151-P63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Sink or Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–26.4 V DC (ON); ≤ 5.0 V DC (OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 mA ±20% per channel at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (signal to system, 1 min); 500 V AC (between commons, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA G3 compliant (corrosive gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eModule Configuration Details\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix P\u003c\/strong\u003e: Pushbutton input for local control or testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix 6\u003c\/strong\u003e: Integrated status display for real-time channel monitoring; non-explosion proof\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix 3\u003c\/strong\u003e: G3 conformal coating with wide temperature tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption D5A00\u003c\/strong\u003e: Pre-fitted ATD5A-00 adapter for simplified KS cable connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003ePrimary Application Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Chemical Plants\u003c\/strong\u003e\u003cbr\u003eReliable operation in environments with sulfurous or acidic gases (G3 compliant).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Acquisition\u003c\/strong\u003e\u003cbr\u003eConsolidated 32-channel input for distributed or centralized process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal Diagnostics and Control\u003c\/strong\u003e\u003cbr\u003ePushbutton and status display allow direct field interaction and rapid troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Systems\u003c\/strong\u003e\u003cbr\u003eDual-redundant configuration ensures uninterrupted monitoring in critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in corrosive chemical plants?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSuffix 3 (G3 option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides protective coating to prevent corrosion from sulfurous or acidic atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the D5A00 option?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00 adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows a single KS cable to carry all 32 channels,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereducing cabinet wiring complexity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It can be configured in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant pairs\u003c\/strong\u003e, ensuring continuous operation for critical monitoring loops.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51687943930168,"sku":"ADV151-P63\/D5A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV151-P63D5A00.jpg?v=1770083113","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-adv151-p63-d5a00-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}