{"product_id":"yokogawa-anr10d-415-er-bus-node-unit","title":"Yokogawa ANR10D-415 ER Bus Node Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANR10D-415\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eER Bus Node Unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems from Yokogawa Electric Corporation. It functions as a critical communication interface between the Field Control Unit (FCU) and remote I\/O modules via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExtended Remote (ER) bus\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“D”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation indicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant architecture\u003c\/strong\u003e, ensuring continuous process operation even if one communication path fails. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-415\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is specifically intended for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100–120 V AC power environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is engineered with enhanced noise immunity to maintain stable communication in electrically harsh industrial installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eANR10D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003e-415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eER Bus (Extended Remote Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant communication channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Context\u003c\/h3\u003e\n\u003cp\u003eThe ANR10D-415 is typically deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale industrial plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere I\/O modules must be installed at significant distances from the central controller. It supports mixed installation of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog and digital I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin a single node, providing a flexible and scalable remote I\/O architecture for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRefinery and petrochemical complexes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge DCS cabinet or marshalling room layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ANR10D-415 support hot-swapping of I\/O modules?\u003c\/strong\u003e\u003cbr\u003eYes. The ER node architecture allows individual I\/O modules to be replaced while the ER bus remains active, provided the system is configured for online maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance for the ER Bus connection?\u003c\/strong\u003e\u003cbr\u003eER Bus distance depends on the cable type used. With standard coaxial cable, distances up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eapproximately 185 meters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be achieved without repeaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the power supply redundant in this model?\u003c\/strong\u003e\u003cbr\u003eYes. The ANR10D-415 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual power supply modules\u003c\/strong\u003e, complementing its redundant communication design and maximizing overall system availability.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51799343399224,"sku":"ANR10D-415","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANR10D-415.jpg?v=1771037170","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-anr10d-415-er-bus-node-unit","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}