{"product_id":"yokogawa-asi533-s00-s1-8-channel-analog-input-module","title":"Yokogawa ASI533-S00 S1 8-Channel Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ASI533-S00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS Safety Instrumented System (SIS)\u003c\/strong\u003e. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3-rated safety loops\u003c\/strong\u003e, this module captures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog signals from field sensors\u003c\/strong\u003e—such as pressure, temperature, or flow transmitters—and provides isolated inputs for robust safety logic processing. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS00 suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout explosion protection, suitable for safe-area cabinet installations.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 isolated channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand fast signal processing, the ASI533-S00 S1 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time detection of abnormal conditions\u003c\/strong\u003e, supporting emergency shutdown (ESD) and Fire \u0026amp; Gas (F\u0026amp;G) systems with high availability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eASI533-S00 (Style Code: S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 isolated input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA current or standard voltage signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity\u003c\/td\u003e\n\u003ctd\u003eSIL3 capable when configured redundantly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003eHigh-speed analog input processing for safety loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eStandard type (Non-Ex, safe area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFits ProSafe-RS Safety Node Units (e.g., SNB10D series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 × 12.7 × 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Application Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI533-S00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical, offshore, and power generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilities where functional safety is critical. It acts as the “eyes” of the safety system,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emonitoring field instrumentation in real time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand triggering immediate system responses when unsafe conditions are detected. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolated channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevent a fault in one sensor from affecting other inputs or the central safety controller, ensuring maximum uptime and reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Can this module be used in corrosive environments?\u003c\/strong\u003e\u003cbr\u003eNo, the S00 is a standard version. For corrosive conditions, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS03 or S53 variants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith ISA G3 conformal coating are recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Is the ASI533-S00 compatible with CENTUM VP?\u003c\/strong\u003e\u003cbr\u003eYes. While it resides in the ProSafe-RS system, it communicates over the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP network\u003c\/strong\u003e, allowing safety data to be displayed on CENTUM VP HIS consoles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. How is SIL3 compliance achieved?\u003c\/strong\u003e\u003cbr\u003eWhen configured in redundant loops and integrated with ProSafe-RS safety controllers, the module meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 functional safety requirements\u003c\/strong\u003e.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51797461074232,"sku":"ASI533-S00 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ASI533-H001.jpg?v=1758869746","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-asi533-s00-s1-8-channel-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}