{"product_id":"yokogawa-cp461-53-centum-vp-dcs-cpu-processor-module","title":"Yokogawa CP461-53 CENTUM VP DCS CPU Processor Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability central processing unit designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Field Control Stations (FCS)\u003c\/strong\u003e, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV30S and AFV40S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodels. It excels in executing complex control logic and managing real-time process data with high deterministic precision. Equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400 MHz 32-bit RISC processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 MB of SDRAM\u003c\/strong\u003e, the CP461-53 delivers the computational performance required for advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID control, sequence management, and multi-loop operations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDesigned for long-term industrial stability, the module supports a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant (Duplex) configuration\u003c\/strong\u003e, allowing instantaneous failover. This ensures critical control loops remain active even during hardware maintenance or unexpected component failures. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA G3 conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenhances the module’s reliability in environments with corrosive gases or harsh industrial conditions.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC high-speed architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd\u003e400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e512 MB Flash (firmware and logic retention)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated battery backup (~72 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Connectivity\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP, ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Mode\u003c\/td\u003e\n\u003ctd\u003eDuplexed configuration for high availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP R5.01 and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eISA G3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e199.5 mm × 145 mm × 16.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe CP461-53 is widely deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density control environments\u003c\/strong\u003e, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoffshore oil platforms, integrated chemical plants, and thermal power stations\u003c\/strong\u003e. It is especially suited for applications requiring a large number of I\/O points and tightly synchronized control across multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Units (FCU)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between CP461-50 and CP461-53?\u003c\/strong\u003e\u003cbr\u003eA: The CP461-53 includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA G3 conformal coating as a standard feature\u003c\/strong\u003e, making it suitable for corrosive environments (e.g., sulfur or chlorine). The CP461-50 may not include this protection by default.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CP461-53 be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eA: Yes. In a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduplexed redundant system\u003c\/strong\u003e, a single CP461-53 can be replaced online without shutting down the controller or interrupting process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with Vnet\/IP?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The CP461-53 is fully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP networks\u003c\/strong\u003e, which serve as the high-speed control backbone for CENTUM VP systems.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51636570816824,"sku":"CP461-53","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CP461-50_S11.jpg?v=1768982012","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-cp461-53-centum-vp-dcs-cpu-processor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}