{"product_id":"yokogawa-ycb301-c100-esb-bus-cable-1m","title":"Yokogawa YCB301-C100 ESB Bus Cable 1m","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa YCB301-C100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed communication cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB (Extended Serial Backplane) and ER bus architectures\u003c\/strong\u003e. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36-pin to 36-pin shielded bus cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables deterministic, real-time data exchange between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Units (FCUs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB \/ ANT node units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems.\u003c\/p\u003e\n\u003cp\u003eEngineered for industrial control cabinets, the YCB301 series ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-latency communication, stable synchronization, and high signal integrity\u003c\/strong\u003e, which are essential for distributed I\/O coordination in both process control and safety systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eYCB301-C100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003e36-pin to 36-pin bus connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Bus\u003c\/td\u003e\n\u003ctd\u003eESB Bus \/ ER Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFCU ↔ ANB \/ ANT node interconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade EMI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in with screw-lock retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe YCB301-C100 is commonly used when\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexpanding Yokogawa DCS architectures\u003c\/strong\u003e, particularly when adding additional I\/O nodes to an existing control station. Typical installation environments include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentral control rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLocal equipment rooms and shelters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and refinery facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLNG processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale power generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is a standard interconnection component for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed ESB \/ ER bus-based I\/O architectures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the YCB301-C100 be used for ER Bus communication?\u003c\/strong\u003e\u003cbr\u003eYes. The YCB301 series supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB and ER bus interfaces\u003c\/strong\u003e, provided installation distances remain within allowable limits for the 1-meter cable length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this cable support redundant configurations?\u003c\/strong\u003e\u003cbr\u003eYes. In\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant FCU systems\u003c\/strong\u003e, two YCB301-C100 cables are typically installed—one for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBus 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand one for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBus 2\u003c\/strong\u003e—to maintain high-availability communication paths.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51746440085816,"sku":"ESB YCB301-C100","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ESB_YCB301-C1001.jpg?v=1770603239","url":"https:\/\/www.automodulexpert.com\/bg\/products\/yokogawa-ycb301-c100-esb-bus-cable-1m","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}