{"title":"Bachmann","description":"\u003cp\u003eBachmann electronic GmbH is a globally recognized expert in factory and machine automation, grid measurement, protection, visualization, and condition monitoring systems. Bachmann offers a wide range of automation solutions, including controllers, I\/O modules, and human-machine interfaces (HMI), for efficient process control.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"bachmann-gio212-universal-i-o-module","title":"Bachmann GIO212 Universal I\/O Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GIO212 Universal Input\/Output Module is a versatile device designed to measure and output a wide range of signals. Each channel can be configured as either an analog or digital input or output. It supports standard signal types such as current (0\/4 to 20 mA) and voltage (±10 V), making it compatible with various sensors and actuators. The module features a 16-bit resolution, allowing for precise measurements even for signals that do not fully utilize the entire measuring range, such as 0 to 5 V.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTemperature measurement is increasingly critical in many processes, and the GIO212 accommodates this by supporting Pt100\/Pt1000 sensors in 2-, 3-, and 4-wire configurations, as well as all standard thermocouples. Additionally, the module's channels can function as digital inputs, which can be configured as interrupt inputs or 32-bit digital counters. For pulse length or period measurements, values can be buffered in a FIFO with a capacity of 1022 values.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 12\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs and Outputs:\u003c\/strong\u003e Analog and Digital Inputs\/Outputs\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eModes per Channel:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAnalog Voltage Input:\u003c\/strong\u003e ±10 V to ±10 mV\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAnalog Current Input:\u003c\/strong\u003e 0(4) to 20 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTemperature Sensor:\u003c\/strong\u003e Pt elements (2-, 3-, 4-wire); Thermocouples (Type J, K, T, N, E, R, S, B)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAnalog Voltage Output:\u003c\/strong\u003e ±10 V\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAnalog Current Output:\u003c\/strong\u003e 0(4) to 20 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Input:\u003c\/strong\u003e 24 V\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital 32-bit Counter:\u003c\/strong\u003e A and A\/B operation\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Output:\u003c\/strong\u003e 100 mA; Low-Side, High-Side, Push-Pull\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Output (PWM\/Frequency Modulation):\u003c\/strong\u003e 16-bit\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e 16-bit with filter\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e 14-bit\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFilter Adjustable Range:\u003c\/strong\u003e 4 kHz to 0.5 Hz per channel\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Status Display:\u003c\/strong\u003e For analog channels\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Inputs Compliance:\u003c\/strong\u003e IEC 61131 Type 1, 2, 3\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e Up to 10 kHz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOverload, Short Circuit, and External Voltage-Proof\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMeasuring Range Monitoring: Freely adjustable (±105 %)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eError Messages: Overload, Overtemperature, and Undervoltage of the Supply\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 500 V from the system\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49117128950072,"sku":"GIO212","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/407406e75322d2ed05545d387220dd03.jpg?v=1723689242"},{"product_id":"bachmann-cpc210-terminal-set","title":"Bachmann CPC210 Terminal Set","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe Bachmann CPC210 is a CompactPCI controller unit designed for use in industrial automation and control systems. It is part of Bachmann's M1 automation system, known for its reliability, modularity, and flexibility in complex automation tasks. The CPC210 serves as the central processing unit (CPU) within a CompactPCI system, managing communication between the modules and executing control tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHigh Performance\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eModular Design\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRobust Construction\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFlexibility\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated Communication\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUser-Friendly Programming\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49117718315320,"sku":"CPC210","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/2c0d5163e06488fb8872c2fb35564948.jpg?v=1723710358"},{"product_id":"bachmann-dms202-strain-gauge-input-module","title":"Bachmann DMS202 Strain Gauge Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BACHMANN \u003cstrong\u003eDMS202 \u003c\/strong\u003eStrain Gauge Input Module is designed for precise measurement and monitoring of strain gauges in various industrial applications, providing high accuracy and reliability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBridge Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCarrier Frequency: 5 kHz ±2%\u003c\/li\u003e\n\u003cli\u003eAmplitude: 4 VRMS ±2%\u003c\/li\u003e\n\u003cli\u003eSynchronization of the Carrier Frequency: Optional\u003c\/li\u003e\n\u003cli\u003eSynchronization Range: 5 kHz ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrain Gauge Amplifier Input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Resistance: \u0026gt; 5 MΩ\u003c\/li\u003e\n\u003cli\u003eDesired Signal Bandwidth: 1 kHz\u003c\/li\u003e\n\u003cli\u003eResolution: 12 bit\u003c\/li\u003e\n\u003cli\u003eMax. Input Common Mode Voltage: 10 V (no overdrive)\u003c\/li\u003e\n\u003cli\u003eCMRR (0 to 5 kHz): \u0026gt; 80 dB\u003c\/li\u003e\n\u003cli\u003eWire Break Monitoring: Yes, with error message\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation from System: 500 V\u003c\/li\u003e\n\u003cli\u003eMonitoring of External Voltage: Yes, power-fail signal\u003c\/li\u003e\n\u003cli\u003eConversion Time: 12.5 µs for one channel, 25 µs for two-channel operation\u003c\/li\u003e\n\u003cli\u003eMeasurement Range Selection: 2.0 \/ 4.0 \/ 8.0 \/ 16.0 mV or Auto Range\u003c\/li\u003e\n\u003cli\u003eMeasurement Range Switchover: Automatic or via software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput Voltage: 0 to 10 V\u003c\/li\u003e\n\u003cli\u003eInternal Resistance: \u0026lt; 2 Ω\u003c\/li\u003e\n\u003cli\u003eLoad Resistor: \u0026gt; 2.5 kΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecial Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak Value Capture\u003c\/li\u003e\n\u003cli\u003eElectronic Capacity Comparison\u003c\/li\u003e\n\u003cli\u003eCarrier Frequency Synchronization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Range: 18 to 34 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption (External): 100 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003eReverse Polarity Protection: Yes\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation from System: 500 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals \/ Certificates:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral: CE, cULus, CCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: 0 to +60 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity (Operation): 5 to 95% without condensation\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -40 to +85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity (Storage): 5 to 95% without condensation\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2 (without condensation; according to IEC 60664-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49282964750648,"sku":"DMS202","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DMS202.jpg?v=1727262983"},{"product_id":"bachmann-gm260-grid-measurement-module","title":"Bachmann GM260 Grid Measurement Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann GM260 \u003c\/strong\u003eGrid Measurement Module is designed for precise current and voltage measurements in grid applications, offering true RMS measurement capabilities, including harmonics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eCurrent Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ≤ ±0.3%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer Rated Current:\u003c\/strong\u003e 1 Arms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring Range:\u003c\/strong\u003e 0.01 to 1.2 Arms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Overload:\u003c\/strong\u003e 1.2 Arms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Term Overload (5x1 s, 300 s interval):\u003c\/strong\u003e 20 Arms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApparent Ohmic Resistance:\u003c\/strong\u003e 75 mVA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eVoltage Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Rated Voltage:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL-L, RMS: 480 Vrms\u003c\/li\u003e\n\u003cli\u003eUL-N, RMS: 277 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Measuring Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL-L, RMS: 70 to 625 Vrms\u003c\/li\u003e\n\u003cli\u003eUL-N, RMS: 36 to 361 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ≤ ±0.1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Overload:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL-L, RMS: 680 Vrms\u003c\/li\u003e\n\u003cli\u003eUL-N, RMS: 390 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Term Overload (10x1 s, 10 s interval):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUL-L, RMS: 1039 Vrms\u003c\/li\u003e\n\u003cli\u003eUL-N, RMS: 600 Vrms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt; 2 MΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFrequency Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Frequency:\u003c\/strong\u003e 50 \/ 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Range:\u003c\/strong\u003e 45 to 65 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ≤ ±0.010 Hz (with averaging filtering down to ≤ ±0.005 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e50 Hz: 20 ms\u003c\/li\u003e\n\u003cli\u003e60 Hz: 16.67 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Measurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured Values:\u003c\/strong\u003e Active (P), Reactive (Q), Apparent (S) power per phase and total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ≤ ±0.4%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalculation Method:\u003c\/strong\u003e DIN 40110-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Interval:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e50 Hz: 20 ms\u003c\/li\u003e\n\u003cli\u003e60 Hz: 16.67 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49282970485048,"sku":"GM260","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/GM260.jpg?v=1727263163"},{"product_id":"bachmann-bs202-backplane","title":"BACHMANN BS202 Backplane","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe backplanes BS201 to BS216 serve as the backbone for the M1 controller hardware modules, providing both mechanical and electrical interconnection for components such as power supplies, CPU modules, and input\/output modules.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eModule Slots:\u003c\/strong\u003e 1 to 16\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSeamless Connection:\u003c\/strong\u003e Allows for easy integration of modules\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStability:\u003c\/strong\u003e Compact design ensures stable mechanics\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVibration Proof:\u003c\/strong\u003e Modules are fixed securely to withstand vibrations\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDIN Rail Compatibility:\u003c\/strong\u003e Can be snapped onto EN 60715 DIN rail\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNumber of Module Slots:\u003c\/strong\u003e 1 to 16\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWidth:\u003c\/strong\u003e 55 mm × (number of module slots)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDepth:\u003c\/strong\u003e 23 mm (including connector)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 119 mm\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eApprovals \/ Certificates:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e CE, cULus, CCC\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMarine:\u003c\/strong\u003e DNV GL, LR, ABS, BV, NK, RINA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAmbient Conditions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 to +60 °C (vertical: -30 to +55 °C)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRelative Humidity (Operation):\u003c\/strong\u003e 5 to 95% (without condensation)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +85 °C\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRelative Humidity (Storage):\u003c\/strong\u003e 5 to 95% (without condensation)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49418458399032,"sku":"BS202","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/3a8445275c82a4ead5ed6fe89af01da7.jpg?v=1730806267"},{"product_id":"bachmann-dio264-c-can-slave-digital-input-output-module","title":"BACHMANN DIO264-C CAN Slave Digital Input\/Output Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe DIO248, DIO264, and DIO280 input\/output modules are designed for controlling digital consumers such as contactors, relays, pneumatic and hydraulic valves. They can also read signals from digital sensors, detectors, or switches. Key features include:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEvent Reaction\u003c\/strong\u003e: Up to 8 configurable interrupt inputs for event reactions.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCounting Capability\u003c\/strong\u003e: Up to 4 counters available for detecting positions or counting items.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePWM Operation\u003c\/strong\u003e: Outputs can be operated as PWM for energy-saving, especially useful for valve operations with a configurable hold time of up to 2 seconds.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eParallel Connectivity\u003c\/strong\u003e: Outputs can be connected in parallel when operated in the same mode.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e: 48, 64, or 80 digital channels available, with 16 channels configurable as input or output.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStatus Display\u003c\/strong\u003e: Each channel has an LED status indicator.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: Supply voltage of 18 to 34 VDC with protection against reverse polarity.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCost-Effective and Space-Saving Design\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDIO248\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDIO264\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDIO280\u003c\/span\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eQuantity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16 to 32\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 to 40\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e32 to 48\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInput Voltage Range (H)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e15 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e15 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e15 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInput Voltage Range (L)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInput Delay (Normally)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStandard: 600 µs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStandard: 600 µs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStandard: 600 µs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSettable Input Delay\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e10 µs to 270 ms\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e10 µs to 270 ms\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e10 µs to 270 ms\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInternal Resistance\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStatus Indication (LED)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInterrupt Inputs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCounter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eQuantity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUp to 4\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUp to 4\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUp to 4\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e32 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e32 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e32 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOperating Mode\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eEvent counter, incremental encoder, gate measurement, cycle time, frequency measurement\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eEncoder Types\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIncremental encoder with A and B channel, one-channel pulse encoder\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInput Signal\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eA, B, Initiator (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eA, B, Initiator (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eA, B, Initiator (configurable)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSignal Evaluation\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 \/ 2 \/ 4-fold edge evaluation, pulse direction mode\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMax Input Frequency\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOne-channel: 50 kHz, Dual-channel (A\/B): 20 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSame as DIO248\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eQuantity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16 to 32\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 to 40\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e32 to 48\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOutput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e18 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e18 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e18 to 34 VDC\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOutput Current per Channel\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMax. 0.5 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMax. 0.5 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMax. 0.5 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTotal Current (Max.)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e20 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 A\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStatus Indication (LED)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGreen\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSwitching Frequency (Max., ohmic load)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInductive Breaking Capacity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1.15 H\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1.15 H\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1.15 H\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePWM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eQuantity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLike outputs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLike outputs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLike outputs\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePulse Duty Ratio \/ Resolution\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 100 % \/ 13 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 100 % \/ 13 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 100 % \/ 13 Bit\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 Hz to 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 Hz to 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 Hz to 1 kHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHolding Time (Valve Mode)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eConfigurable 0 to 2 s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eConfigurable 0 to 2 s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eConfigurable 0 to 2 s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStart\/Stop\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBy dedicated output\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBy dedicated output\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBy dedicated output\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInternal Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGalvanic Isolation from System\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e500 V\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e500 V\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e500 V\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInternal Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBS2xx\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBS2xx\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBS2xx\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eInternal Current Consumption (at 5 V)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e180 mA\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e180 mA\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e180 mA\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49418461511992,"sku":"DIO264-C","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/36e8ffc335d002aa2a0b0aa13a4c5c44.jpg?v=1730806516"},{"product_id":"bachmann-mx220-processor-module","title":"BACHMANN MX220 Processor Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe MX200 series processor modules combine outstanding environmental robustness with compact dimensions. Key features include:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIntegrated Power Supply:\u003c\/strong\u003e Powers both the module and I\/O devices, facilitating a complete basic system implementation using only 2 module widths.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eScalable CPU Performance:\u003c\/strong\u003e Equipped with industrial processors and scalable clock frequencies, making it suitable for small to medium-sized applications.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Capable of handling machine control, simple motion control, various communication tasks, and condition monitoring efficiently.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eReal-Time Multi-Tasking:\u003c\/strong\u003e Allows multiple programs to run in parallel, enhancing operational efficiency.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEasy Upgrades:\u003c\/strong\u003e Applications can be transferred to more powerful CPU models as needed.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFanless Operation:\u003c\/strong\u003e Designed for extreme operating conditions, supporting temperatures from -30 to +60 °C due to a generous thermal design and special coating processes.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor Speed:\u003c\/strong\u003e Up to 433 MHz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMultitasking:\u003c\/strong\u003e Priority scheduled\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e256 MB RAM\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e512 kB remanent memory (Retain)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e64 MB internal memory\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage Options:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompactFlash card slot for removable media\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFront-side PC-Card slot\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x Ethernet 10\/100 Mbit\/s\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x RS232, 1x RS232\/RS422\/RS485, 1x USB 2.0\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCAN\/CANopen support\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIntegrated Power Supply:\u003c\/strong\u003e For I\/O modules\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMX207\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMX213\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\t\t\t\u003cth\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMX220\u003c\/strong\u003e\u003c\/span\u003e\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eArchitecture\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ex86 \/ AMD LX\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ex86 \/ AMD LX\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ex86 \/ AMD LX\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCPU\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIndustrial Low Voltage\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIndustrial Low Voltage\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIndustrial Low Voltage\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eClock Frequency\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e266 MHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e266 MHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e433 MHz\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eProcessor Cores\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHyper-Threading\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMultitasking\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eReal-time-SMP \/ Core Reservation\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMain Memory \/ Partitions\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e256 MB \/ Yes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e256 MB \/ Yes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e256 MB \/ Yes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRamdisk\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRetentive Memory (Retain)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e512 kB NVRAM\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e512 kB NVRAM\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e512 kB NVRAM\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMass Storage Integrated\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e64 MB\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e64 MB\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e64 MB\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMass Storage Removable\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompact Flash (via side cover)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompact Flash (via side cover)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompact Flash (via side cover)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePC-Card front side (16\/32\/64 MB)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePC-Card front side (16\/32\/64 MB)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePC-Card front side (16\/32\/64 MB)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eI\/O Subsystem\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBachmann M1 Backplane Interface\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBachmann M1 Backplane Interface\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBachmann M1 Backplane Interface\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eProcess Image Controller\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCyclic Process Images\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eEthernet\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x 10\/100 Base-Tx (RJ45)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x 10\/100 Base-Tx (RJ45)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x 10\/100 Base-Tx (RJ45)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSerial Ports \/ COM\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x RS232 (D-SUB-9 m)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x RS232 (D-SUB-9 m)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x RS232\/RS422\/RS485 (D-SUB-9 m)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x RS232\/RS422\/RS485 (D-SUB-9 m)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUSB\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x USB 2.0 (type-A f)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x USB 2.0 (type-A f)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x USB 2.0 (type-A f)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCAN\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x CAN \/ CANopen \/ J1939 (D-SUB-9 m), isolated; up to 1Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x CAN \/ CANopen \/ J1939 (D-SUB-9 m), isolated; up to 1Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x CAN \/ CANopen \/ J1939 (D-SUB-9 m), isolated; up to 1Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOperating Modes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCAN Master, CAN IO Device\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCAN Master, CAN IO Device\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCAN Master, CAN IO Device\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIndication \u0026amp; Operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eStatus Indications\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e3x LED for CPU status (RUN \/ INIT \/ ERR)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e3x LED for CPU status (RUN \/ INIT \/ ERR)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e3x LED for CPU status (RUN \/ INIT \/ ERR)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x LED for status and link speed per ETH port\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x LED for status and link speed per ETH port\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x LED for status and link speed per ETH port\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOperating Elements\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x 16-position rotary switch (Hex-switch)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x 16-position rotary switch (Hex-switch)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2x 16-position rotary switch (Hex-switch)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eGeneric Build Target\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, across all model families\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, across all model families\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, across all model families\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLanguages\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIEC 61131-3, C\/C++, MATLAB®\/Simulink®\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIEC 61131-3, C\/C++, MATLAB®\/Simulink®\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIEC 61131-3, C\/C++, MATLAB®\/Simulink®\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFunctional Modules\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (e.g., MotionControl, Camming, CNC, adaptive temperature control)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (e.g., MotionControl, Camming, CNC, adaptive temperature control)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (e.g., MotionControl, Camming, CNC, adaptive temperature control)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eProcessor Temperature\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eProcessor Load\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRuntime Behaviour\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, cycle monitoring \u0026amp; watchdog\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, cycle monitoring \u0026amp; watchdog\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, cycle monitoring \u0026amp; watchdog\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eNetwork Load\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMemory Protection\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, per partition\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, per partition\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, per partition\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, with interrupt signal\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, with interrupt signal\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes, with interrupt signal\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSubsystems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eReal Time Clock\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (rechargeable battery buffered RTC for time\/date), sync capability over IEEE 1588, SNTP\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (rechargeable battery buffered RTC for time\/date), sync capability over IEEE 1588, SNTP\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes (rechargeable battery buffered RTC for time\/date), sync capability over IEEE 1588, SNTP\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEnergy Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 VDC (18 to 34 V)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 VDC (18 to 34 V)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 VDC (18 to 34 V)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eConnector Terminal\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eKZ 51\/03 RM 5.08; 3-pol.\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eKZ 51\/03 RM 5.08; 3-pol.\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eKZ 51\/03 RM 5.08; 3-pol.\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePolarity Reversal Protection\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIsolation of Supply\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eVoltage Interruptions Immunity\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e(IEC 61131-2) PS2\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e(IEC 61131-2) PS2\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e(IEC 61131-2) PS2\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRated Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWithout I\/O\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 W (5 V \/ 1400 mA, 15 V \/ 30 mA, -15 V \/ 30 mA)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e9.5 W (5 V \/ 1700 mA, 15 V \/ 30 mA, -15 V \/ 30 mA)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e9.5 W (5 V \/ 1700 mA, 15 V \/ 30 mA, -15 V \/ 30 mA)\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWith I\/O\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e33.6 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e33.6 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e33.6 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRated Power Output for I\/O\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e18.25 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16.75 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16.75 W\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMaximum Currents for I\/O\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e+5 V \/ 2800 mA; +15 V \/ 250 mA; -15 V \/ 200 mA\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e+5 V \/ 2800 mA; +15 V \/\u003c\/span\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49418464133432,"sku":"MX220","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/2cda56ea21d147f61ff7958990d32ac4.jpg?v=1730806700"},{"product_id":"bachmann-ti214-temperature-input-module","title":"Bachmann | TI214 | Temperature Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann TI214 \u003c\/strong\u003eTemperature Input Module is designed for high-accuracy temperature measurement in industrial applications, supporting a range of sensor types and providing versatile input options for precise and reliable thermal data acquisition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: 14 inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type\u003c\/strong\u003e: Pt100\/Pt1000 (3-wire or 2-wire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter\u003c\/strong\u003e: Low pass filter (1st order)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCutoff Frequency\u003c\/strong\u003e: 17 kHz (Pt100\/Pt1000), 8 Hz (Thermocouples)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor Types and Measurement Ranges\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouples\u003c\/strong\u003e: J, K, N, S (insulated\/uninsulated, programmable)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ\/K\u003c\/strong\u003e: -30 to +1000 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: -30 to +1300 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: -30 to +1600 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePt100\/Pt1000\u003c\/strong\u003e: -100 to +800 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant Current\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePt100: 2 mA\u003c\/li\u003e\n\u003cli\u003ePt1000: 200 µA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e: 14 bits (16-bit representation with averaging)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValue of LSB\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePt100\/Pt1000: 0.055 K\u003c\/li\u003e\n\u003cli\u003eThermocouples J\/K: 0.062 K\u003c\/li\u003e\n\u003cli\u003eThermocouples N: 0.08 K\u003c\/li\u003e\n\u003cli\u003eThermocouples S: 0.098 K\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Accuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePt100\/Pt1000: ±0.1% at 25°C\u003c\/li\u003e\n\u003cli\u003eThermocouples J\/K: ±0.15% at 25°C\u003c\/li\u003e\n\u003cli\u003eThermocouples N: ±0.15% at 25°C\u003c\/li\u003e\n\u003cli\u003eThermocouples S: ±0.25% at 25°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConversion Time\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80 ms\u003c\/strong\u003e with 16-fold averaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e320 ms\u003c\/strong\u003e with 64-fold averaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 ms\u003c\/strong\u003e without averaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Linearization\u003c\/strong\u003e: Polynomial (IEC60584 Part 1) for J\/K, N\/S types\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eError Detection\u003c\/strong\u003e: Wire break\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Voltage Strength\u003c\/strong\u003e: -36 to +36 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Power Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e: 18 to 34 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: 500 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: 160 mA at 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApprovals and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral\u003c\/strong\u003e: CE, cULus, CCC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine\u003c\/strong\u003e: DNV GL, LR, ABS, BV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -30 to +60 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 to +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity (Operation)\u003c\/strong\u003e: 5 to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity (Storage)\u003c\/strong\u003e: 5 to 95% (with condensation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree\u003c\/strong\u003e: 2 (per IEC 60664-1)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49444778672440,"sku":"TI214","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/TI214_1.jpg?v=1731571905"},{"product_id":"bachmann-mx213-processor-module-w-512mb-card","title":"BACHMANN MX213 Processor Module w\/ 512MB Card","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMX200 Series (Compact) Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe MX200 series processor modules are compact and robust, designed for industrial applications. With an integrated power supply unit that supports I\/O module power and communication interfaces, the MX200 series enables complete basic system setups within just two module widths. These processors offer scalable CPU performance, suitable for small to medium-sized applications such as:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMachine control\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSimple motion control\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCommunication tasks\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCondition monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe real-time multitasking capability allows multiple programs to run virtually in parallel. If higher CPU performance is needed, applications can easily migrate to more powerful CPU models due to the standard programming framework.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eArchitecture:\u003c\/strong\u003e x86 \/ AMD LX\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCPU:\u003c\/strong\u003e Industrial Low Voltage\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eClock Frequency:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX207: 266 MHz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX213: 266 MHz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX220: 433 MHz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor Cores:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHyper-Threading:\u003c\/strong\u003e Not supported\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMultitasking:\u003c\/strong\u003e Supported\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eReal-time SMP \/ Core Reservation:\u003c\/strong\u003e Not supported\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMain Memory \/ Partitions:\u003c\/strong\u003e 256 MB \/ Supported\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRamdisk:\u003c\/strong\u003e Supported\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRetentive Memory (Retain):\u003c\/strong\u003e 512 kB NVRAM\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMass Storage (Integrated):\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX207\/MX213: 64 MB\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMass Storage (Removable):\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompact Flash (via side cover)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePC-Card (16\/32\/64 MB)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eI\/O Subsystem:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBachmann M1 Backplane Interface\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated Process Image Controller\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSynchronization pulse for I\/O and field buses\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEthernet:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX207: 1x 10\/100 Base-Tx (RJ45)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX213\/MX220: 2x 10\/100 Base-Tx (RJ45), AutoNegotiation, AutoCrossing\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSerial Ports (COM):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX207: None\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX213\/MX220: 1x RS232 (D-SUB-9 m)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eUSB:\u003c\/strong\u003e 1x USB 2.0 (Type-A)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCAN:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1x CAN \/ CANopen \/ J1939 (D-SUB-9 m), isolated, up to 1 Mbit\/s\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOperating Modes: CAN Master, CAN IO Device\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLanguages:\u003c\/strong\u003e IEC 61131-3, C\/C++, MATLAB®\/Simulink®\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFunctional Modules:\u003c\/strong\u003e Motion Control, Camming, CNC, Adaptive Temperature Control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor:\u003c\/strong\u003e Temperature, Load, Runtime Behavior, and Memory Protection\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNetwork Load:\u003c\/strong\u003e Supported\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSupply Voltage Monitoring:\u003c\/strong\u003e With interrupt signal\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEnergy Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 VDC (18 to 34 V)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConnector:\u003c\/strong\u003e Terminal for socket KZ 51\/03 RM 5.08; 3-pin\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWithout I\/O: 8 W (MX207) \/ 9.5 W (MX213\/MX220)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWith I\/O: 33.6 W\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRated Output for I\/O:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX207: 18.25 W\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMX213\/MX220: 16.75 W\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 to +60 °C (fanless)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +85 °C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% (with\/without condensation)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e Up to 2000 m (derated operation up to 4500 m)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProduct Safety:\u003c\/strong\u003e CE, cULus, CCC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e DNV, LR, ABS, BV, NK, KR, RINA\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNumber of Slots \/ Module Units:\u003c\/strong\u003e 2\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 110 x 119 x 61 mm\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 660 g (MX207) \/ 675 g (MX213\/MX220)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSystem Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBackplane:\u003c\/strong\u003e BS2xx, BS2xx\/S, BS2xx\/E\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e Minimum MxCCore V3.80 (recommended MxCCore V4.30)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49462143680824,"sku":"MX213","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/a2f99c901fa661461c636556b6e28576.jpg?v=1732090975"},{"product_id":"bachmann-fs221-n-fastbus-module","title":"BACHMANN FS221\/N FASTBUS Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe FASTBUS modules \u003cstrong\u003eFM221, FM222, FS221\/N,\u003c\/strong\u003e and \u003cstrong\u003eFS222\/N\u003c\/strong\u003e are designed for distributed substation applications over long distances with minimal signal delay. These modules feature an integrated power supply in the FASTBUS slave modules \u003cstrong\u003eFS221\/N\u003c\/strong\u003e and \u003cstrong\u003eFS222\/N\u003c\/strong\u003e, capable of supplying power to I\/O modules within a substation. Flexible connector options allow for easy connections using either patch cables or industrial-grade push-pull plugs with an adapter.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFASTBUS Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLine length\u003c\/strong\u003e:\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMaximum 2000 m between stations\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTotal length: up to 2300 m\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTransmission medium\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMultimode fiber (50\/125 µm and 62.5\/125 µm), max. 2000 m\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFOC connector type\u003c\/strong\u003e: LC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFOC guide wavelength\u003c\/strong\u003e: 1310 nm\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNumber of stations\u003c\/strong\u003e: Max. 16 (up to 10 per line)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLink budget\u003c\/strong\u003e: \u0026gt;8 dB (includes 3 dB reserve)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFiber optic cable received light output\u003c\/strong\u003e:\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHardware\u003c\/strong\u003e: Three-color status LED\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e: 0–100% indication\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIntegrated Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e: 24 VDC (range: 18 to 34 V)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNominal power output\u003c\/strong\u003e: 18.25 W\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput current\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e+5 V: 3000 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e+15 V: 250 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e-15 V: 200 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eApprovals \/ Certificates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e: CE, cULus, CCC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMarine\u003c\/strong\u003e: DNV GL, LR, ABS, BV\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAmbient Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -30°C to +60°C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRelative humidity (operation)\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e5% to 95%, without condensation\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e5% to 95%, with condensation\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -40°C to +85°C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRelative humidity (storage)\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e5% to 95%, with condensation\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003ePollution degree: 2 (according to IEC 60664-1)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49462153249080,"sku":"FS221\/N","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/e46525e28e6ae62d010f87f603f47e07.jpg?v=1732091198"},{"product_id":"bachmann-slc284-safety-processor-module","title":"BACHMANN SLC284 Safety Processor Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eSLC284 Safety Digital Input Module\u003c\/strong\u003e is designed to operate as a safe, modern, and independent safety controller, ideally integrated into the \u003cstrong\u003eM200 Controller\u003c\/strong\u003e. It complies with \u003cstrong\u003eIEC 61508\u003c\/strong\u003e safety standards and supports communication with safety I\/O modules such as \u003cstrong\u003eSDI208\u003c\/strong\u003e and \u003cstrong\u003eSDO204\u003c\/strong\u003e without additional cabling. The modules can be distributed and separated by several hundred meters, operating via:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBus Expansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFASTBUS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCAN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBluecom\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCPU:\u003c\/strong\u003e Dual LPC2468 processors, 72 MHz, 32-bit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProgramming Interface:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eVia controller (I\/O bus)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSerial interface (COM)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNumber of Independent Safety Programs per SLC:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProgram Cycle:\u003c\/strong\u003e Minimum 5 ms\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eI\/O Expansion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCompatible with \u003cstrong\u003eSDI208\u003c\/strong\u003e, \u003cstrong\u003eSDO204\u003c\/strong\u003e, or \u003cstrong\u003eSCT202\u003c\/strong\u003e modules\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e16 digital inputs (redundantly usable in pairs, PL e \/ SIL 3 \/ Cat 4)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHigh (H): 15 V DC to 34 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLow (L): -34 V DC to +5 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Delay:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHardware: 300 µs (typical)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSoftware: 1 ms (typical, with disabled test pulsing)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e IEC 61131-2 Type 1\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMinimum Input Current:\u003c\/strong\u003e 3.5 mA at 24 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Green LED\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eError Monitoring:\u003c\/strong\u003e Internal function monitoring; optional external test pulsing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e8 digital outputs (redundantly usable in pairs, PL e \/ SIL 3 \/ Cat 4)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 18 V DC to 34 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Current per Channel:\u003c\/strong\u003e 0.5 A nominal\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTotal Current per Group (Max):\u003c\/strong\u003e 2 A\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSwitching Delays:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0 to 1: Max. 35 µs at full load\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1 to 0: Max. 155 µs at full load\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Groups:\u003c\/strong\u003e 2 (with electronic fuse)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSwitching Frequency (Max, Resistive Load):\u003c\/strong\u003e 500 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStatus Indication:\u003c\/strong\u003e Green LED\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eError Monitoring:\u003c\/strong\u003e Short-circuit, overload, undervoltage, overvoltage of power supply\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eEmergency Shut-Off:\u003c\/strong\u003e Configurable per output from 0 s to 1800 s (100 ms resolution). Emergency shut-off activates on communication or supply voltage failure.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInternal Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSystem: 500 V\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eBetween Groups: 500 V\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSource:\u003c\/strong\u003e Backplanes BS2xx\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInternal Current Consumption:\u003c\/strong\u003e 5 V \/ 550 mA via backplane\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e Reverse polarity\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 V DC (18 V to 34 V)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTypical: 95 mA at 24 V DC + Σ current consumption of actuators and sensors\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch4\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eI\/O Connection:\u003c\/strong\u003e RM 3.5 connector with flange\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower Supply Connection:\u003c\/strong\u003e RM 5.08 connector with flange\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Screw or spring terminal, connectors are codable and labelable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":49462162424120,"sku":"SLC284","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/c7663aed4e37b306b1a89cd03998c08c.jpg?v=1732091338"},{"product_id":"dio248-bachmann-digital-input-output-module","title":"DIO248 | Bachmann Digital Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: DIO248\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO248\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a space-saving digital I\/O module from Bachmann, featuring flexible configuration and efficient performance for automation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChannel Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e: 48 digital\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput\/Output Flexibility\u003c\/strong\u003e: 16 channels configurable as input or output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e: LED for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterrupt Inputs\u003c\/strong\u003e: Configurable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCounter Function\u003c\/strong\u003e: 32-bit, supports event counting, encoder, gate time, period, and frequency measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWM Output\u003c\/strong\u003e: Ideal for valve economy mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e: Configurable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e: 18 V DC to 34 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePolarity Protection\u003c\/strong\u003e: Reverse polarity protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50274833006904,"sku":"DIO248","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DIO248_2.jpg?v=1747991943"},{"product_id":"bachmann-acr222-2-axis-controller-module","title":"Bachmann ACR222\/2 Axis Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: ACR222\/2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eACR222\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-axis controller module from Bachmann, designed for interfacing with stepper motor output stages and incremental encoders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMotion Control Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStepper Motor Interfaces\u003c\/strong\u003e: 2 channels, up to 150 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder Interfaces\u003c\/strong\u003e: 2 channels, up to 1 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpeed Profiles\u003c\/strong\u003e: Linear, sin², parabolic acceleration; two-step linear speed profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput \u0026amp; Monitoring\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch Inputs\u003c\/strong\u003e: Home, abort, and 2 limit switches per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder Power Supply\u003c\/strong\u003e: Delivered via module connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Monitoring\u003c\/strong\u003e: External supply monitored for reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50274844967224,"sku":"ACR222\/2","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ACR2222.jpg?v=1747992092"},{"product_id":"mpc270-bachmann-programmable-logic-controller-module","title":"MPC270 | Bachmann Programmable Logic Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: MPC270\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC270\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a modular, quad-core PLC by Bachmann designed for high-performance industrial automation, offering flexible communication and extensive I\/O capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; Memory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e: Quad-core, 1.5 GHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRAM\u003c\/strong\u003e: 4 GB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlash Storage\u003c\/strong\u003e: 32 GB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInterfaces \u0026amp; I\/O\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e: Ethernet, RS-232, RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e: Supports up to 2560 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 11 cm × 5.5 cm × 12 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.66 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50274852536632,"sku":"MPC270","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MPC270_2.jpg?v=1747991943"},{"product_id":"dio216-bachmann-digital-input-output-module","title":"DIO216 Bachmann Digital Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIO216\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby Bachmann is a 16-channel digital input\/output module designed for isolated 24 V, 1 A operation with 3-wire technology.\u003c\/p\u003e\n\u003ch3\u003eInput Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum inputs\u003c\/strong\u003e: 16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh input voltage range\u003c\/strong\u003e: 15 to 34 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow input voltage range\u003c\/strong\u003e: 0 to 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTypical input delay\u003c\/strong\u003e: 600 μs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal resistance\u003c\/strong\u003e: 6.8 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus LEDs\u003c\/strong\u003e: Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterrupt inputs\u003c\/strong\u003e: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum outputs\u003c\/strong\u003e: 16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput voltage range\u003c\/strong\u003e: 18 to 34 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax current per channel\u003c\/strong\u003e: 1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax total current\u003c\/strong\u003e: 16 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus LEDs\u003c\/strong\u003e: Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax switching frequency (ohmic load)\u003c\/strong\u003e: 1 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower and Isolation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReverse polarity protection\u003c\/strong\u003e: Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic isolation from system\u003c\/strong\u003e: 500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -30 to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating humidity\u003c\/strong\u003e: 5 to 95% (no condensation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -40 to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage humidity\u003c\/strong\u003e: 5 to 95% (with condensation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50299853865272,"sku":"DIO216","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DIO216_1.jpg?v=1748252569"},{"product_id":"bachmann-ptai216-temperature-input-module","title":"Bachmann | PTAI216 Temperature Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePTAI216\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature input module from Bachmann supports 4 analog inputs and 12 channels for Pt100\/Pt1000 temperature sensors with galvanic isolation and diagnostic features.\u003c\/p\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog input channels\u003c\/strong\u003e: 4 (±10 V \/ ±1 V \/ 0–20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTD sensor channels\u003c\/strong\u003e: 12 (Pt100\/Pt1000)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput type (analog)\u003c\/strong\u003e: Single-ended or differential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor wiring\u003c\/strong\u003e: 2-wire for Pt100\/Pt1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 14-bit (analog), 12-bit (Pt100\/Pt1000)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSample time\u003c\/strong\u003e: 2.5 ms (analog), 480 ms (Pt100\/Pt1000)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel isolation\u003c\/strong\u003e: Galvanically isolated from system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Wire break detection and power supply monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50299931296056,"sku":"PTAI216","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PTAI216_2.jpg?v=1748252569"},{"product_id":"mpc240-bachmann-512mb-cf-processor-module","title":"MPC240 Bachmann 512MB CF Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor module from Bachmann delivers powerful, reliable performance for advanced automation and control tasks in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e: MPC240\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e: PowerPC 405, 240 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDRAM\u003c\/strong\u003e: 512 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlash Storage\u003c\/strong\u003e: 128 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Range\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.65 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLength\u003c\/strong\u003e: 11.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 6.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 12.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50299963441464,"sku":"MPC240","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MPC240.jpg?v=1748252569"},{"product_id":"fs211-n-bachmann-fastbus-module","title":"FS211\/N Bachmann FASTBUS Module","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFS211\/N\u003c\/strong\u003e is a FASTBUS Slave Module from Bachmann, built to support distributed SubDevices with integrated power supply and low-latency communication across long fiber optic links.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: FASTBUS slave with integrated power supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e: 1 or 2 FO (fiber optic) interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Topology\u003c\/strong\u003e: Up to 15 distributed SubDevices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTransmission Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOF Cables\u003c\/strong\u003e: Up to 40 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHCS Cables\u003c\/strong\u003e: Up to 150 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecial HCS Cables\u003c\/strong\u003e: Up to 180 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay\u003c\/strong\u003e: Very low latency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e: RUN\/ERR LEDs, fiber type display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Supplies I\/O modules in distributed systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50304514261304,"sku":"FS211\/N","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/FS211N_1.jpg?v=1748338680"},{"product_id":"fastbus-module-fm211-bachmann","title":"FASTBUS Module FM211 | Bachmann","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFM211\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bachmann FASTBUS master module with 1 or 2 fiber optic (FO) interfaces, designed for efficient communication and power distribution in industrial networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: FASTBUS master and slave modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e: 1 or 2 FO interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubDevices\u003c\/strong\u003e: Supports up to 15 distributed SubDevices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTransmission Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOF Cables\u003c\/strong\u003e: Up to 40 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHCS Cables\u003c\/strong\u003e: Up to 150 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpecial HCS Cables\u003c\/strong\u003e: Up to 180 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e: RUN\/ERR display, fiber type display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay\u003c\/strong\u003e: Minimal latency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 V DC (18 V to 34 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: Max. 1.2 A at 24 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Output Power\u003c\/strong\u003e: 17 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Currents\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+5 V: 2800 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+15 V: 250 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-15 V: 200 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic isolation 500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReverse polarity protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50304526418232,"sku":"FM211","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/FM211_1.jpg?v=1748338680"},{"product_id":"bachmann-isi222-8-positioning-module","title":"Bachmann ISI222\/8 Positioning Module","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann ISI222\/8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a positioning module designed for advanced motion control applications, providing precise control over two motion axes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 input channels for incremental and SSI encoders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull 32-bit counter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 analog outputs with 14-bit resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 fast digital inputs for initiator and trigger signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePosition measurement and storage triggered via inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVirtual inputs for zero pulse, velocity, and other applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchronization through SYNC\/PreSYNC signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEncoder power supply provided by the module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring of encoder voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable break detection for encoders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports input frequencies up to 8 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables highly dynamic and precise movements through integrated system synchronization (I\/O-Bus-Sync)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50304536510776,"sku":"ISI222\/8","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ISI2228_2.jpg?v=1748338680"},{"product_id":"isi202-encoder-interface-module-bachmann","title":"ISI202 Encoder Interface Module | Bachmann","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eISI202\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed encoder interface module supporting incremental and SSI encoders with accurate signal processing and analog output.\u003c\/p\u003e\n\u003ch3\u003eInput Channels\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncremental or SSI encoder: 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital (reference, trigger): 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Channels\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog output: 2 (±10 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEncoder Power Supply\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupplied directly via connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVoltage Monitoring\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors all external supply voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaximum Input Frequency\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 MHz \/ 5 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCounter Resolution\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 bits (expandable to 32 bits via software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInput Signals\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA-, A+, B-, B+, N-, N+\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50343243153720,"sku":"ISI202","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ISI202_2.jpg?v=1748603530"},{"product_id":"mpc240-w-bachmann-processor-module","title":"MPC240\/W | Bachmann | Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMPC240\/W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged, compact processor module based on Celeron\/Pentium III architecture, designed for tough industrial use.\u003c\/p\u003e\n\u003ch3\u003eProcessor \u0026amp; Memory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCPU: Celeron \/ Pentium III, 400 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSRAM: 512 kB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003envRAM: 64 kB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlash Memory: 8 MB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInterfaces\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSerial ports: 1× RS232, 1× RS232\/422\/485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet: 2× 10\/100 Base-TX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUSB: 1× USB 1.1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpansion Slots: PCC and CF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temp: -30 to +60 °C, fanless\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: 5–95%, no condensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temp: -40 to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Humidity: 5–95%, no condensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50343255310648,"sku":"MPC240\/W","price":254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MPC240W_1.jpg?v=1748603530"},{"product_id":"nt250-bachmann-power-supply-module","title":"NT250 Bachmann Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNT250\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a power supply module built to deliver stable voltage and current for industrial use.\u003c\/p\u003e\n\u003ch3\u003ePower Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range: 38–58 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeak Input Voltage: +60 V (t \u0026lt; 1 s\/min)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush Current: Max 7 A (\u0026lt; 0.5 s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Voltage\/Current: +5 V\/6.0 A, +15 V\/0.5 A, -15 V\/0.5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Power: 42 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic Isolation: 500 V (input\/bus), 100 V (input\/ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Conditions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: 5% to 95%, no condensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Humidity: 5% to 95%, no condensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":50343256228152,"sku":"NT250","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NT250_1.jpg?v=1748603530"},{"product_id":"bus-master-module-for-automation-networks-cm202-bachmann","title":"Bus Master Module for Automation Networks CM202 BACHMANN","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann CM202 is a high-performance CAN fieldbus master module engineered for robust communication in industrial control systems. It is part of Bachmann’s modular automation platform and is widely used in sectors such as energy, marine, and manufacturing. The module enables seamless integration of distributed devices using Controller Area Network (CAN) technology, which is known for its reliability and noise immunity.\u003c\/p\u003e\n\u003cp\u003eMoreover, the CM202 supports two galvanically isolated CAN interfaces, allowing it to operate two completely independent CAN networks simultaneously. This dual-channel architecture enhances system flexibility and fault tolerance. In addition, the module supports multiple CAN-based protocols including CANopen, J1939, and NMEA 2000, which can be configured via Bachmann’s SolutionCenter software using EDS files or application-level programming.\u003c\/p\u003e\n\u003cp\u003eIts rugged design ensures stable performance even in environments with high electrical interference, vibration, or temperature variation. Therefore, the CM202 is a trusted solution for engineers building scalable and resilient automation systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 × 280 × 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–25°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann CM202 is widely used in industrial systems requiring reliable and scalable CAN communication:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Integrates sensors and controllers in wind turbines, substations, and power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine Automation\u003c\/strong\u003e: Supports navigation, engine control, and onboard diagnostics via NMEA 2000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e: Connects PLCs, HMIs, and I\/O modules in distributed automation networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation\u003c\/strong\u003e: Enables vehicle diagnostics and control in rail and heavy equipment systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e: Facilitates real-time communication in chemical and pharmaceutical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts dual CAN interface and protocol flexibility make it ideal for complex, multi-network environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protocols does the CM202 support?\u003c\/strong\u003e\u003cbr\u003eA: CANopen, J1939, NMEA 2000, and proprietary protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it operate two CAN networks simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it has two independent, galvanically isolated CAN channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is it configured?\u003c\/strong\u003e\u003cbr\u003eA: Using Bachmann’s SolutionCenter software with EDS files or custom programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this module?\u003c\/strong\u003e\u003cbr\u003eA: Energy, marine, manufacturing, transportation, and process automation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it offers high EMI resistance and operates from –25°C to +70°C.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307297603896,"sku":"CM202","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CM202.jpg?v=1762160583"},{"product_id":"fm221-bachmann-plc-control-module","title":"FM221 BACHMANN PLC Control Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann FM221 PLC Control Module is engineered for precise control and efficient operation in complex automation systems. As part of Bachmann’s modular controller family, it delivers fast processing, reliable communication, and seamless integration with distributed I\/O and fieldbus networks.\u003c\/p\u003e\n\u003cp\u003eMoreover, the FM221 supports FastBus architecture, enabling high-speed data exchange between modules and controllers. Its compact design and low power consumption make it suitable for space-constrained installations, while its rugged build ensures stable performance in harsh industrial conditions. Therefore, it is widely used in applications requiring real-time control, fault tolerance, and scalable system architecture.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module is compatible with Bachmann’s engineering tools and programming environments, allowing for flexible configuration and diagnostics. Its CE certification and wide operating temperature range make it a trusted solution for long-term deployment in mission-critical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFM221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann FM221 module is widely used in industrial systems requiring high-speed control and robust communication:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Controls wind turbines, substations, and distributed power networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Automation\u003c\/strong\u003e: Manages robotic cells, conveyors, and process control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine and Offshore\u003c\/strong\u003e: Supports engine control, navigation systems, and onboard diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation Infrastructure\u003c\/strong\u003e: Powers rail automation, traffic signaling, and tunnel ventilation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Industries\u003c\/strong\u003e: Executes batch control, safety interlocks, and real-time monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts FastBus interface and modular design make it ideal for scalable and fault-tolerant architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main function of the FM221 module?\u003c\/strong\u003e\u003cbr\u003eA: It serves as a central control unit for real-time automation tasks in industrial systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocol does it use?\u003c\/strong\u003e\u003cbr\u003eA: It uses Bachmann’s proprietary FastBus for high-speed module communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating voltage range?\u003c\/strong\u003e\u003cbr\u003eA: 18–34 VDC, with nominal operation at 24 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it operates reliably from –40°C to +70°C and is CE certified.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this module?\u003c\/strong\u003e\u003cbr\u003eA: Energy, manufacturing, marine, transportation, and process automation.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307298521400,"sku":"FM221","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/FM2211.jpg?v=1762160584"},{"product_id":"bachmann-bs206-i-o-bus-coupler-module-for-industrial-automation","title":"BACHMANN BS206 I\/O Bus Coupler Module for Industrial Automation","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann Electronic BS206 is a high-performance backplane module engineered for demanding automation systems in sectors such as rail, mining, energy, and heavy manufacturing. It serves as the backbone for connecting multiple control modules, including power supplies, CPUs, and I\/O units, within the M200 system architecture.\u003c\/p\u003e\n\u003cp\u003eWhat sets the BS206 apart is its metrological precision and environmental resilience. It achieves ±0.1% baseline accuracy with 16-bit resolution, and features auto-calibration routines that reduce long-term drift and maintenance needs by up to 50%. Moreover, its conformal-coated PCBs and EN 61373-certified connectors withstand 5g vibrations and 50g shocks, making it suitable for mobile and outdoor installations.\u003c\/p\u003e\n\u003cp\u003eIn addition, the BS206 includes advanced diagnostics that continuously monitor signal integrity. It can detect underrange\/overrange conditions, sensor wire breaks, and shunt faults, with timestamped fault logs that synchronize with control CPUs via POWERLINK for rapid troubleshooting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBS206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe BS206 is optimized for industrial systems requiring modular scalability, high signal fidelity, and environmental durability:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRail Automation\u003c\/strong\u003e: Used in onboard control systems and trackside monitoring in extreme climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMining Operations\u003c\/strong\u003e: Supports mobile equipment and remote control stations in rugged terrain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Infrastructure\u003c\/strong\u003e: Powers turbine control, substation automation, and grid synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Industries\u003c\/strong\u003e: Integrates with chemical, pharmaceutical, and food processing control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine and Offshore\u003c\/strong\u003e: Withstands vibration and salt exposure in shipboard and platform automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the BS206 module?\u003c\/strong\u003e\u003cbr\u003eA: It serves as a backplane for connecting and powering up to six Bachmann control modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What makes it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: It features conformal-coated PCBs, vibration-resistant connectors, and operates from –40°C to +70°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How accurate is its signal processing?\u003c\/strong\u003e\u003cbr\u003eA: It offers ±0.1% accuracy with 16-bit resolution and auto-calibration to reduce drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic features are included?\u003c\/strong\u003e\u003cbr\u003eA: It monitors signal integrity, detects faults, and logs timestamped errors for fast root-cause analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use the BS206?\u003c\/strong\u003e\u003cbr\u003eA: Rail, mining, energy, marine, and process automation.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307298685240,"sku":"BS206","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/BS206.jpg?v=1762160584"},{"product_id":"compact-memory-module-for-industrial-plc-controllers-bachmann-pcc200","title":"Compact Memory Module for Industrial PLC Controllers Bachmann PCC200","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann PCC200 memory card is engineered for secure data storage and fast access in Bachmann M200 programmable logic controller (PLC) systems. It stores essential system components such as operating systems, application software, source code, and configuration files, ensuring smooth operation and quick recovery in industrial environments.\u003c\/p\u003e\n\u003cp\u003eMoreover, the PCC200 is built with non-volatile flash memory, which retains data even during power loss. Its compact form factor and rugged design make it suitable for embedded control systems, especially in sectors like energy, transportation, and manufacturing. In addition, the card supports write protection via software, helping prevent accidental overwrites or unauthorized changes.\u003c\/p\u003e\n\u003cp\u003eThe PCC200 is compatible with Bachmann processor modules and can also interface with PCs using the A-PCC200 adapter, allowing for flexible programming and diagnostics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCC200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cp\u003eThe PCC200 memory card is widely used in industrial automation systems requiring reliable data retention and fast boot-up:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Stores turbine control logic and grid synchronization routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation\u003c\/strong\u003e: Powers embedded control systems in rail and marine automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e: Holds machine programs and diagnostics for robotic and assembly lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e: Maintains batch recipes, alarm logs, and safety configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInfrastructure Automation\u003c\/strong\u003e: Supports water treatment, HVAC, and utility control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts compatibility with Bachmann M200 controllers makes it a key component in modular and scalable automation architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the memory capacity of the PCC200?\u003c\/strong\u003e\u003cbr\u003eA: It offers 8 MB of non-volatile flash memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with PCs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, via the A-PCC200 adapter for programming and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage does it operate at?\u003c\/strong\u003e\u003cbr\u003eA: 5 V nominal, with a minimum of 3 V for flash memory access.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it withstand harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it operates from 0°C to +60°C and stores data from –40°C to +85°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this card?\u003c\/strong\u003e\u003cbr\u003eA: Energy, transportation, manufacturing, and process automation.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307307401528,"sku":"PCC200","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PCC200.jpg?v=1762160583"},{"product_id":"wt205v-bachmann-control-panel-for-m1-automation-systems","title":"WT205V Bachmann Control Panel for M1 Automation Systems","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann WT205V Control Panel is engineered for reliable operation in harsh industrial environments, offering a compact and durable interface for automation and monitoring systems. It is part of Bachmann’s modular control platform and is widely used in sectors such as oil and gas, mining, smart ports, and semiconductor manufacturing.\u003c\/p\u003e\n\u003cp\u003eThis panel supports robust data acquisition, real-time monitoring, and secure control functions, making it ideal for mission-critical applications. Moreover, it integrates predictive maintenance features and embedded security protocols, ensuring long-term system stability and protection against cyber threats.\u003c\/p\u003e\n\u003cp\u003eIts compact footprint and DIN rail mounting allow for easy integration into existing control cabinets. The WT205V is also designed to withstand extreme temperatures, vibration, and airborne contaminants, making it suitable for both indoor and outdoor installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWT205V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe WT205V is widely used in industrial systems that require compact, secure, and high-performance control interfaces:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil and Gas\u003c\/strong\u003e: Supports wellhead control, pipeline monitoring, and remote diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Ports and Logistics\u003c\/strong\u003e: Manages crane automation, container tracking, and access control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSemiconductor Manufacturing\u003c\/strong\u003e: Enables precise process control and cleanroom integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMining Operations\u003c\/strong\u003e: Withstands vibration and dust in mobile and fixed installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Integrates with wind, solar, and substation automation platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts predictive maintenance support and secure communication make it ideal for modern IIoT and Industry 4.0 environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the power supply requirement for the WT205V?\u003c\/strong\u003e\u003cbr\u003eA: It operates on 24 VDC and supplies 12 VDC and 24 VDC to local and field circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it withstands –40°C to +70°C, 10g shock, and high vibration levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eA: It supports Ethernet, Modbus, and TCP\/IP for industrial networking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used for predictive maintenance?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes embedded diagnostics and predictive maintenance features.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this panel?\u003c\/strong\u003e\u003cbr\u003eA: Oil and gas, mining, energy, smart infrastructure, and semiconductor manufacturing.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307307630904,"sku":"WT205V","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/WT205V.jpg?v=1762160584"},{"product_id":"bachmann-00014647-00-fieldbus-interface-module-for-industrial-automation","title":"Bachmann 00014647-00 Fieldbus Interface Module for Industrial Automation","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann 00014647-00 Communication Interface Module enables seamless connectivity between Bachmann programmable logic controllers (PLCs) and BACnet MS\/TP networks, commonly used in building management systems (BMS) and HVAC infrastructures. It is engineered for fast device discovery, flexible object management, and secure data exchange, making it ideal for scalable automation environments.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module supports key BACnet functions such as property access, alarm and event handling, and time synchronization. Its plug-and-play design simplifies installation and configuration, while built-in diagnostic tools help monitor network health and troubleshoot communication issues. Therefore, it’s a trusted solution for engineers integrating Bachmann systems into BACnet ecosystems.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module is CE-certified and built to operate reliably in industrial conditions. It is available in new condition with original packaging and includes a 12-month warranty.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00014647-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBACnet Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann 00014647-00 module is widely used in industrial and commercial systems requiring BACnet integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilding Management Systems (BMS)\u003c\/strong\u003e: Connects HVAC controllers, lighting systems, and access control devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Links PLCs with BACnet-compatible sensors and actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Management\u003c\/strong\u003e: Facilitates data exchange between power meters and control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Infrastructure\u003c\/strong\u003e: Supports centralized monitoring in smart buildings and campuses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e: Enables BACnet-based communication in chemical and pharmaceutical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts support for up to 128 objects makes it suitable for large-scale deployments with diverse device types.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protocol does the 00014647-00 module support?\u003c\/strong\u003e\u003cbr\u003eA: BACnet MS\/TP for building and industrial automation networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many BACnet objects can it manage?\u003c\/strong\u003e\u003cbr\u003eA: Up to 128 objects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it easy to install?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it features plug-and-play installation and automatic device discovery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What diagnostic features are included?\u003c\/strong\u003e\u003cbr\u003eA: Built-in tools for network monitoring and troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this module?\u003c\/strong\u003e\u003cbr\u003eA: Building automation, energy management, industrial control, and smart infrastructure.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307308450104,"sku":"00014647-00","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/00014647-001.jpg?v=1762160583"},{"product_id":"industrial-ethernet-switch-swi205-bachmann","title":"Industrial Ethernet Switch SWI205 Bachmann","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann SWI205 Industrial Ethernet Switch is engineered for stable and efficient data exchange in demanding industrial environments. It ensures seamless communication between PLCs, controllers, HMIs, and field devices across automation networks. With support for 10\/100 Mbps Ethernet, the SWI205 delivers fast and secure connectivity for real-time control and monitoring.\u003c\/p\u003e\n\u003cp\u003eMoreover, its compact and rugged design allows for easy installation in control cabinets and field enclosures. The switch operates reliably in extreme temperatures, making it suitable for outdoor and mobile applications. In addition, its low power consumption and DIN rail mounting simplify integration into existing systems.\u003c\/p\u003e\n\u003cp\u003eManufactured in Austria and backed by CE and RoHS certifications, the SWI205 is a trusted solution for engineers building scalable and fault-tolerant industrial networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSWI205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.8 cm × 5.5 cm × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe SWI205 is widely used in industrial systems requiring robust Ethernet communication and environmental resilience:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Plants\u003c\/strong\u003e: Connects PLCs, sensors, and HMIs for real-time control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Supports substation automation and renewable energy monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation Infrastructure\u003c\/strong\u003e: Powers rail signaling, tunnel control, and traffic systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine and Offshore\u003c\/strong\u003e: Withstands vibration and salt exposure in shipboard automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Buildings\u003c\/strong\u003e: Integrates HVAC, lighting, and access control systems via Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts compact form and wide temperature range make it ideal for mobile equipment, outdoor installations, and remote monitoring stations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Ethernet speeds does the SWI205 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 10 Mbps and 100 Mbps via 10\/100BaseT Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for outdoor or mobile use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it operates from –40°C to +85°C and is built for rugged environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the input voltage?\u003c\/strong\u003e\u003cbr\u003eA: It operates on 24 VDC with 5 W power consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is it mounted?\u003c\/strong\u003e\u003cbr\u003eA: It mounts easily on DIN rails in control cabinets or enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this switch?\u003c\/strong\u003e\u003cbr\u003eA: Manufacturing, energy, transportation, marine, and smart infrastructure.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307319755064,"sku":"SWI205","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SWI2051.jpg?v=1762160583"},{"product_id":"ai204-2-bachmann-analog-input-module","title":"AI204\/2 BACHMANN Analog Input Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann AI204\/2 Analog Input Module is designed for accurate signal acquisition in industrial automation systems. It belongs to the AI204\/x family, known for its high-resolution 16-bit analog inputs and integrated temperature calibration, ensuring exceptional measurement accuracy even in fluctuating environmental conditions.\u003c\/p\u003e\n\u003cp\u003eThis module features four differential analog input channels, each capable of handling multiple voltage ranges. Engineers can select from ±10 V, ±5 V, ±2.5 V, or ±1.25 V depending on the application. Moreover, the AI204\/2 offers low noise performance, fast sampling, and robust signal integrity, making it suitable for precision monitoring and control tasks.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module is built for harsh industrial environments, with CE certification and a compact form factor that fits seamlessly into Bachmann’s modular automation racks. Its reliability and flexibility make it a trusted component in energy, manufacturing, and process control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI204\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 cm × 12.4 cm × 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe AI204\/2 module is widely used in industrial systems requiring precise analog signal acquisition:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Systems\u003c\/strong\u003e: Monitors voltage and current in wind turbines, solar arrays, and substations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Automation\u003c\/strong\u003e: Captures sensor data for quality control, machine diagnostics, and process feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e: Measures pressure, temperature, and flow in chemical and pharmaceutical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation Infrastructure\u003c\/strong\u003e: Supports environmental monitoring and control in rail and tunnel systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResearch and Development\u003c\/strong\u003e: Enables high-resolution data logging in test benches and lab automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts selectable voltage ranges and differential inputs make it ideal for noise-sensitive environments and multi-sensor configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input channels does the AI204\/2 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 4 differential analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage ranges are available?\u003c\/strong\u003e\u003cbr\u003eA: ±10 V, ±5 V, ±2.5 V, and ±1.25 V, selectable per channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the resolution of the module?\u003c\/strong\u003e\u003cbr\u003eA: It offers 16-bit analog-to-digital conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes temperature calibration and CE certification for industrial use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this module?\u003c\/strong\u003e\u003cbr\u003eA: Energy, manufacturing, transportation, process control, and R\u0026amp;D.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307320181048,"sku":"AI204\/2","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AI2042.jpg?v=1762160584"},{"product_id":"bachmann-bs208-modular-backplane-rack","title":"Bachmann BS208 Modular Backplane Rack","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Bachmann BS208 Base Rack is a robust and scalable mounting platform designed for industrial automation systems. It accommodates up to eight SMD modules, including CPUs, I\/O units, and communication interfaces, forming the backbone of Bachmann’s M1 controller architecture. Its passive backplane ensures reliable data and power distribution across all connected modules.\u003c\/p\u003e\n\u003cp\u003eBuilt with high-strength aluminum, the BS208 withstands vibration, temperature fluctuations, and harsh operating conditions. Moreover, its compact form factor and DIN rail compatibility make it easy to integrate into control cabinets and distributed automation setups. Engineers rely on the BS208 for its mechanical stability, long-term durability, and seamless module connectivity.\u003c\/p\u003e\n\u003cp\u003eIn addition, the rack supports passive cooling, eliminating the need for fans and reducing maintenance overhead. Therefore, it is ideal for applications where uptime and environmental resilience are critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Data \/ Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e438 mm × 121 mm × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe BS208 is widely used in industrial environments requiring modular control and high system reliability. Its typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e: Serves as the foundation for machine control systems in packaging and assembly lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Infrastructure\u003c\/strong\u003e: Supports turbine automation and substation monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMobile Platforms\u003c\/strong\u003e: Ideal for mobile and offshore installations, thanks to its rugged design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Control Systems\u003c\/strong\u003e: Offers flexibility for system integrators by enabling fast module replacement and expansion without disrupting operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts compatibility with Bachmann’s M1 series ensures seamless integration across diverse automation tasks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What modules are compatible with the BS208 rack?\u003c\/strong\u003e\u003cbr\u003eA: It supports all SMD modules from Bachmann’s M1 controller series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is active cooling required for this rack?\u003c\/strong\u003e\u003cbr\u003eA: No, the BS208 uses passive cooling optimized for airflow and heat dissipation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be mounted vertically or horizontally?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports both DIN rail and panel mounting configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the rack suitable for outdoor or mobile installations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, its aluminum construction and wide temperature range make it ideal for harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use the BS208?\u003c\/strong\u003e\u003cbr\u003eA: Manufacturing, energy, transportation, marine, and process automation sectors.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307320312120,"sku":"BS208","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/BS208.jpg?v=1762160583"},{"product_id":"processor-module-mpc265-bachmann","title":"Processor Module MPC265 Bachmann","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann MPC265 Processor Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for demanding automation tasks across industries such as energy, manufacturing, marine, and process control. As part of Bachmann’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC series\u003c\/strong\u003e, it serves as the central processing unit within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM1 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, delivering high-performance control and communication capabilities.\u003c\/p\u003e\n\u003cp\u003ePowered by a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePentium-class III processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erunning at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.6 GHz\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC265\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for fast execution of control logic, motion algorithms, and communication protocols. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time multitasking\u003c\/strong\u003e, enabling precise synchronization across distributed systems.\u003c\/p\u003e\n\u003cp\u003eIn terms of communication, the module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual Ethernet interfaces\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCAN bus\u003c\/strong\u003e, and redundant\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS\/PROFINET ports\u003c\/strong\u003e, making it well-suited for complex, networked environments. Additionally, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOPC UA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol stacks allow seamless connectivity with IIoT devices and SCADA platforms.\u003c\/p\u003e\n\u003cp\u003eWith its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP67 protection rating\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC265\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for harsh environments, including offshore platforms, wind turbines, and mobile equipment. It also offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable redundancy\u003c\/strong\u003e, with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efailover times under 50 ms\u003c\/strong\u003e, minimizing downtime in critical systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Data \/ Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPC265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTypical Applications \/ System Integration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC265\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in industrial systems requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time control\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault tolerance\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIIoT integration\u003c\/strong\u003e. Typical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRenewable Energy\u003c\/strong\u003e: Controls pitch and yaw systems in wind turbines, with predictive maintenance based on vibration and temperature data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMarine Engineering\u003c\/strong\u003e: Powers dynamic positioning systems (DP) in ships, managing propulsion control and sensor fusion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Automation\u003c\/strong\u003e: Supports EtherCAT-based motion control in CNC machines and robotic arms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Industries\u003c\/strong\u003e: Replaces traditional DCS systems in chemical and power plants, offering high-speed PID control and safety logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Infrastructure\u003c\/strong\u003e: Enables edge computing and protocol conversion in smart buildings and utility networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC265\u003c\/strong\u003e's modular design and protocol flexibility make it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecross-domain integration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escalable automation platforms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What processor does the MPC265 use?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC265\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePentium-class III\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCPU running at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.6 GHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support redundant operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual power inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable CPU redundancy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efailover times under 50 ms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication protocols are available?\u003c\/strong\u003e\u003cbr\u003eA: The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOPC UA\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/RTU\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFINET\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCAN bus\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for outdoor or offshore use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it has an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP67 rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand operates from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–20°C to +70°C\u003c\/strong\u003e, making it suitable for harsh environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What industries commonly use this module?\u003c\/strong\u003e\u003cbr\u003eA:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnergy\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emarine\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanufacturing\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esmart infrastructure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustries commonly use this module.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51307357372728,"sku":"MPC265","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/MPC265.jpg?v=1762161945"},{"product_id":"bachmann-00016586-00-4gb-compact-flash-card-for-devices","title":"Bachmann 00016586-00 4GB Compact Flash Card for Devices","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann 00016586-00 4GB Compact Flash Card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for demanding industrial automation environments. It provides reliable data storage for controllers, embedded systems, and machine interfaces where durability and consistency are critical. Moreover, its robust design ensures stable operation even under continuous workloads. In addition, the card offers long-term availability, making it suitable for projects requiring guaranteed lifecycle support.\u003c\/p\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e00016586-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact Flash (CF) Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e1.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUsed in programmable logic controllers for storing firmware and application data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplied in industrial PCs and HMIs requiring stable non-volatile memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for motion control systems where continuous logging is essential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated into energy management devices for secure configuration storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeployed in transportation automation systems requiring ruggedized memory solutions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is this CF card compatible with standard industrial controllers?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports IDE\/ATA interfaces widely used in automation controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How durable is the card in harsh environments?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt withstands high shock and vibration levels, ensuring reliable performance in heavy-duty applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the card be used for long-term projects?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. It offers guaranteed lifecycle support and industrial-grade endurance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What industries typically use this product?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is commonly used in manufacturing, energy, transportation, and process automation sectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Does the card require special installation tools?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, it can be inserted directly into standard CF slots without additional accessories.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51476187283768,"sku":"00016586-00","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/00016586-00.jpg?v=1764926349"},{"product_id":"aio288-analog-input-output-module-bachmann-industrial","title":"AIO288 Analog Input Output Module Bachmann Industrial","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann AIO288 Analog Input\/Output Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to deliver high accuracy and reliability in modular automation environments. It efficiently converts analog signals into digital data and vice versa, supporting a wide range of voltage, current, and temperature sensor inputs. Moreover, its compact DIN rail design allows seamless integration into existing control systems. In addition, the module ensures robust performance under demanding industrial conditions, making it a trusted choice for engineers and system integrators.\u003c\/p\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIO288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 × 75 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring and controlling analog signals in chemical, pharmaceutical, and food industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in power plants and renewable energy systems for precise sensor integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotion Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for servo systems requiring fast sampling and accurate feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransportation Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApplied in rail and marine automation for rugged and reliable signal handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial PCs and HMIs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides stable analog interfaces for visualization and operator control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many channels does the AIO288 provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt offers 8 analog input channels and 8 analog output channels in one compact module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it handle temperature sensors directly?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports up to 4 Pt100\/Pt1000 sensors with 2-wire or 4-wire connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What makes it suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes wire break detection, short circuit protection, and overload monitoring for reliable operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the sampling speed adequate for dynamic processes?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. With a 200 µs sampling time, it ensures responsive control in fast-changing applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What industries typically use the AIO288?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is widely used in manufacturing, energy, transportation, and modular automation systems.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51476194525496,"sku":"AIO288","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIO288.jpg?v=1764926350"},{"product_id":"bachmann-mpc293-mpc200-industrial-cpu-processor-module","title":"Bachmann MPC293 MPC200 Industrial CPU Processor Module","description":"\u003ch2\u003eBachmann MPC293 MPC200 CPU Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic real-time control and high-speed data acquisition within the Bachmann M1 Automation Platform, the \u003cstrong\u003eBachmann MPC293\u003c\/strong\u003e (\u003cstrong\u003eMPC293\u003c\/strong\u003e CPU Processor Module) provides direct physical\/electrical execution. Operating as an embedded x86 processor unit on the internal backplane bus, the module executes motion algorithms, multi-tasking software routines, and industrial network communications across distributed control architectures. The fanless hardware manages high-density system I\/O updates via deterministic Ethernet and serial interfaces without operational thermal degradation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMPC293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 160 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V, +\/-15 V via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Unit\u003c\/td\u003e\n\u003ctd\u003eEmbedded Pentium-class CPU (400 \/ 650 \/ 700 \/ 933 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB DRAM, 512 KB SRAM (battery-backed), 64 KB nvRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Storage\u003c\/td\u003e\n\u003ctd\u003e8 MB internal FLASH, PC card (32\/64 MB), CF card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Communication\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet (10\/100 Base-TX), 1 x RS232, 1 x RS232\/422\/485, 1 x USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann MPC293 optimizes backplane bus communication velocity across the internal M1 backplane to deliver microsecond-level loop synchronization. Interfacing directly with local digital and analog I\/O modules, the x86 CPU architecture maintains deterministic memory access cycles, bypassing processing latencies common to non-real-time field networks. Integrated dual 10\/100 Base-TX Ethernet controllers utilize hardware-based packet timing to manage Profinet and EtherNet\/IP deterministic communications. Firmware flash compatibility via external CF cards allows field engineers to upgrade system kernels and application logic without disturbing system calibration parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the MPC293 manage power distribution across the internal backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The module draws regulated 5 VDC and +\/-15 VDC supply rails directly from the M1 power supply card via the backplane back-plane connectors. Technicians must verify total system bus current draw to prevent voltage drop across distant I\/O expansion racks.\u003c\/p\u003e\n\u003cp\u003eQ: What retains user program data and dynamic system variables during a full power outage?\u003c\/p\u003e\n\u003cp\u003eA: Non-volatile 64 KB nvRAM retains critical parameters without battery reliance, while the 512 KB SRAM relies on an integrated backup battery to store runtime data buffers during complete system shutdowns.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MPC293 module vertically into the designated M1 base rack slot, pressing firmly to seat the backplane multi-pin connector before tightening the top and bottom retaining screws. Maintain a minimum top and bottom clearance of 50 mm inside the enclosure to enable natural convection airflow across the fanless heat sink assembly. Ground the M1 rack chassis directly to the central cabinet earth bar using a heavy copper grounding strap.\u003c\/p\u003e\n\u003cp\u003eRoute all communication cabling (Ethernet, serial, USB) separately from 230 VAC power supply conduits to eliminate electromagnetic interference. Ensure field-installed CompactFlash cards are locked behind the protective front door assembly to prevent dust contamination during continuous operation.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890573766968,"sku":"MPC293","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/243..jpg?v=1788255789"},{"product_id":"aio208-m1-bachmann-automation-system-analog-controller-module","title":"AIO208 M1 Bachmann Automation System Analog Controller Module","description":"\u003ch2\u003eBachmann AIO208 M1 Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann AIO208\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAIO208\u003c\/strong\u003e Analog Input\/Output Module, operates as a dedicated hardware component for universal analog signal measurement and actuator output within Bachmann M1 Automation System platforms. The unit converts field sensor variables into high-resolution digital data across 8 independently configurable channels. Interfacing directly with the internal backplane bus, the module processes voltage, current, resistance temperature detector (RTD), and thermocouple inputs while executing analog command signals to final control elements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIO208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M1 Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane powered (Standard M1 Bus Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 Configurable Analog Input \/ Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, +\/-1 V, +\/-100 mV, +\/-10 mV, +\/-20 mA, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensors\u003c\/td\u003e\n\u003ctd\u003ePt100\/Pt1000 (2-, 3-, 4-wire), Thermocouples (J, K, T, N, E, R, S, B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V (max 10 mA), 0(4)-20 mA (max load 600 ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput \/ Output Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit Input (with filter), 14-bit Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Refresh Cycle\u003c\/td\u003e\n\u003ctd\u003e100 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V Galvanic Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann AIO208 leverages internal backplane bus communication velocity to deliver a fast 100 us refresh cycle across all 8 channels. Combining analog input and output functions on a single board maximizes I\/O density scaling within the M1 rack, eliminating the need for separate dedicated cards. Dynamic digital filters update on a per-channel basis from 4 kHz down to 0.5 Hz to reject electrical noise while preserving fast loop throughput. Solid hardware-level firmware flash compatibility ensures synchronized parameter updates across distributed control structures without interrupting system scan cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does 500 V galvanic isolation protect signal conversion accuracy across mixed channel configurations?\u003c\/p\u003e\n\u003cp\u003eA: Integrated 500 V galvanic isolation isolates the field wiring signals from the internal logic backplane and adjacent channel groups. This barrier suppresses common-mode voltage spikes, preventing ground loop noise from corrupting millivolt-level thermocouple or RTD measurements.\u003c\/p\u003e\n\u003cp\u003eQ: What happens to channel output signals when the system detects an overtemperature or short-circuit fault?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic engine monitors output circuits continuously. Upon detecting a short circuit or overtemperature condition, the module triggers hardware protection loops, trips localized channel status bits, and forces the affected output into a safe de-energized state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the AIO208 vertically into the Bachmann M1 base rail slot until the backplane connector locks firmly into place. Secure the top and bottom retaining screws to ensure continuous chassis grounding. Route low-level thermocouple and RTD signal leads through shielded twisted-pair cables, keeping them strictly separated from AC power lines by a minimum clearance of 300 mm.\u003c\/p\u003e\n\u003cp\u003eGround cable shields at a single point on the cabinet entry grounding bar to eliminate ground loop currents. When connecting 3-wire or 4-wire Pt100 sensors, ensure uniform wire resistance across all leads to maintain specified measurement accuracy. Torque terminal block connections to manufacturer specs prior to applying power to the rack.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890603487544,"sku":"AIO208","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/244.jpg?v=1788256173"},{"product_id":"bachmann-bs209-m1-system-9-slot-backplane-module","title":"Bachmann BS209 M1 System 9 Slot Backplane Module","description":"\u003ch2\u003eBachmann BS209 M1 Backplane Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann BS209\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBS209\u003c\/strong\u003e Backplane Module, operates as a dedicated hardware component for mechanical support and internal bus signal routing within Bachmann M1 Automation System platforms. The 9-slot base plate establishes high-speed backplane power and data connections across power supply modules, CPU units, and expansion I\/O cards. Engineered for EN 60715 DIN rail installation, the unit maintains vibration-proof locking mechanisms to secure module interfaces against mechanical shock during continuous operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBS209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e495 x 137 x 23 mm (Width: 55 mm x 9 slots, Height with grounding tab: 137 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C (Horizontal), -30 to +55 deg C (Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Backplane Bus Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003e9 Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eEN 60715 DIN Rail Snap-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eClass 1 (with protective conductor grounding tab)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann BS209 maximizes backplane bus communication velocity by maintaining low-impedance copper bus traces across all 9 slots. This bus topology enables deterministic microsecond data transfers between central processing units and attached I\/O cards. By scaling I\/O density within a single compact footprint, the module eliminates external inter-rack wiring bottlenecks. The hardware interface preserves firmware flash compatibility across installed cards, allowing seamless controller communications without introducing physical signal reflections or latency overhead.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the BS209 handle protective grounding across installed cards?\u003c\/p\u003e\n\u003cp\u003eA: The backplane incorporates an integrated Class 1 grounding tab that accepts a dedicated protective earth conductor. When installed on an EN 60715 DIN rail, internal spring contacts establish direct grounding paths from each module slot to the central cabinet earth bar.\u003c\/p\u003e\n\u003cp\u003eQ: Are there thermal derating limits associated with vertical mounting orientations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When technicians install the BS209 in a vertical orientation, the maximum operating temperature limit drops from +60 deg C to +55 deg C to account for natural convection heat dissipation profiles across upper module slots.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the BS209 backplane horizontally onto an EN 60715 DIN rail inside the enclosure, ensuring all panel retaining clips snap firmly onto the steel rail profile. Connect a dedicated protective earth copper cable to the bottom grounding tab before installing active modules to ensure proper Class 1 chassis grounding.\u003c\/p\u003e\n\u003cp\u003eSeat each M1 module vertically into its assigned slot position, pushing straight back until the rear multi-pin connector seats completely into the backplane header. Tighten all top and bottom module retaining screws to secure vibration-proof contact points. Maintain a minimum top and bottom clearance of 50 mm around the backplane assembly to ensure unobstructed vertical airflow.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890630947128,"sku":"BS209","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/245..jpg?v=1788256474"},{"product_id":"automation-12-slot-backplane-base-board-bachmann-bs212-m1","title":"Automation 12-Slot Backplane Base Board Bachmann BS212 M1","description":"\u003ch2\u003eBachmann BS212 M1 Backplane Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann BS212\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBS212\u003c\/strong\u003e Backplane Module, operates as a dedicated hardware component for mechanical support and internal bus signal routing within Bachmann M1 Automation System platforms. Equipped with 12 module slots and dual expansion interfaces, the hardware establishes high-speed power and data connections for local I\/O modules, power supplies, and communication units. The base plate supports distributed I\/O topologies across up to 6 substations via daisy-chain CAT7 cabling, providing deterministic real-time data transfers across the system bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBS212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M1 12-Slot Backplane Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive bus distribution (17 W nominal on BES212\/N variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003e12 Module Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Bus Expansion Interfaces (RJ45, CAT7 cable up to 3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Latency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 us access time delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion\u003c\/td\u003e\n\u003ctd\u003eUp to 6 substations (max 15 M200\/M1 modules per station)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSnap-on EN 60715 DIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann BS212 optimizes backplane bus communication velocity across distributed racks by utilizing point-to-point hardware expansion links with minimal propagation delays under 1.5 us. High-density I\/O routing scales across multiple stations without needing protocol conversion gateways or specialized network software routines. The module backplane retains strict firmware flash compatibility across all connected digital, analog, and communication cards, ensuring synchronized memory access cycles during high-speed PLC scan executions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What grounding requirements must be met when operating the BS212 with non-SELV voltage modules?\u003c\/p\u003e\n\u003cp\u003eA: The backplane chassis features a dedicated protective conductor tab. Installers must bond this tab directly to the cabinet earth bus using a short, high-strand copper strap to satisfy Class 1 protection requirements for non-SELV circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated power supply function on the BES212\/N hardware variant?\u003c\/p\u003e\n\u003cp\u003eA: The BES212\/N variant accepts an 18-34 VDC input (1.2 A at 24 VDC) and outputs regulated internal backplane voltages of +5 VDC (2 A), +15 VDC (250 mA), and -15 VDC (200 mA) to power remote I\/O slots.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSnap the BS212 base plate securely onto an EN 60715 DIN rail or bolt it directly to the cabinet backpanel. Connect the protective earth conductor to the integrated grounding tab prior to installing active hardware cards. Mount active modules vertically into their assigned slots, ensuring multi-pin backplane connectors align fully before tightening the upper and lower retaining screws.\u003c\/p\u003e\n\u003cp\u003eFor multi-rack expansion, connect CAT7 cables with shielded RJ45 connectors between the dual expansion ports, limiting station-to-station runs to a maximum of 3 m. Keep communication lines separated from high-voltage AC power wiring inside wireways by at least 300 mm to prevent signal interference.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890657718584,"sku":"BS212","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/246.jpg?v=1788256736"},{"product_id":"bachmann-fs212-n-m1-fastbus-fiber-optic-slave-module","title":"Bachmann FS212\/N M1 FASTBUS Fiber Optic Slave Module","description":"\u003ch2\u003eBachmann FS212\/N FASTBUS Slave Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for optical fiber bus communication and distributed substation expansion in Bachmann M1 Automation System networks, the \u003cstrong\u003eBachmann FS212\/N\u003c\/strong\u003e (\u003cstrong\u003eFS212\/N\u003c\/strong\u003e FASTBUS Slave Module) provides direct physical\/electrical execution. The module interfaces upstream controllers to remote I\/O nodes over dual fiber optic channels, maintaining signal integrity across isolated segments. Featuring an integrated 17 W power supply unit, the hardware regulates internal backplane power rails for attached sub-modules while routing high-speed field bus data across noise-prone industrial environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS212\/N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard M1 Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC input (18-34 VDC, max 1.2 A at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Fiber Optic (FO) Interfaces (POF, HCS, Special HCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Output\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (2800 mA), +15 VDC (250 mA), -15 VDC (200 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Latency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 us per node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Distance\u003c\/td\u003e\n\u003ctd\u003e40 m (POF), 150 m (HCS), 180 m (Special HCS); 1000 m Total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 15 distributed substations (16 total stations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann FS212\/N leverages backplane bus communication velocity to process optical serial streams with a propagation delay under 1.5 us. Integrating dual fiber optic ports allows ring or line topologies that expand I\/O density scaling across a 1000 m total network length without electrical noise coupling. The hardware maintains firmware flash compatibility across connected nodes, ensuring real-time control cycle synchronization and immediate diagnostic relay via front-panel RUN\/ERR status indicators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated power supply stage supply local backplane rails?\u003c\/p\u003e\n\u003cp\u003eA: The internal DC-DC converter accepts an 18-34 VDC primary line and delivers regulated secondary outputs of +5 VDC (2800 mA), +15 VDC (250 mA), and -15 VDC (200 mA) directly to the adjacent module slots via the backplane header.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are necessary regarding maximum fiber segment length?\u003c\/p\u003e\n\u003cp\u003eA: Transmission limits depend strictly on the optical fiber medium used: standard Polymer Optical Fiber (POF) must not exceed 40 m, standard Hard Clad Silica (HCS) supports up to 150 m, and special HCS variants allow maximum link distances of 180 m between nodes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the FS212\/N vertically into the designated M1 backplane slot until the rear connector seats firmly, then torque the module retaining screws to secure mechanical grounding. Verify that incoming 24 VDC power wiring matches polarity before terminal connection; reverse polarity protection prevents circuit damage but halts power generation to the backplane.\u003c\/p\u003e\n\u003cp\u003eClean all fiber optic connectors prior to insertion into the dual FO transceivers. Maintain the minimum allowable bend radius for POF or HCS cables within cable ducts to avoid signal attenuation or optical fiber fracture. Route fiber lines away from sharp panel edges and high-voltage motor conductors.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890677575992,"sku":"FS212\/N","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/247..jpg?v=1788257016"},{"product_id":"mx220-2g-bachmann-mx200-series-master-cpu-controller-module","title":"MX220\/2G Bachmann MX200 Series Master CPU Controller Module","description":"\u003ch2\u003eBachmann MX220\/2G MX200 CPU Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic real-time control and high-speed multi-tasking execution in Bachmann M1 Automation System architectures, the \u003cstrong\u003eBachmann MX220\/2G\u003c\/strong\u003e (\u003cstrong\u003eMX220\u003c\/strong\u003e CPU Processor Module) provides direct physical\/electrical execution. The module coordinates real-time field bus transactions, serial data streams, and internal backplane bus operations across attached I\/O cards. Operating via integrated Ethernet, CANbus, and serial communication channels, the fanless unit updates system variables and executes IEC 61131-3 logic without active cooling components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMX220\/2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 119 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C (Fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e9.5 W (CPU only), up to 33.6 W with I\/O module load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Unit\u003c\/td\u003e\n\u003ctd\u003ex86 industrial processor (433 MHz \/ 1.91 GHz variant dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e256 MB RAM \/ 2 GB DDR3 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetentive Storage\u003c\/td\u003e\n\u003ctd\u003e512 KB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Expansion\u003c\/td\u003e\n\u003ctd\u003eCFast \/ CompactFlash slot (2 GB included, supports up to 256 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet (10\/100 Mbit\/s), 1 x RS232, 1 x RS232\/422\/485, 1 x USB 2.0, 1 x CAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18-34 VDC input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Output\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (1700 mA), +15 VDC (30 mA), -15 VDC (30 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann MX220\/2G drives backplane bus communication velocity across the internal rack to achieve microsecond-level synchronization across local and expansion sub-modules. Hardware-level bus arbitration ensures jitter-free processing of motion loops and high-density I\/O scans. Integrated dual 10\/100 Mbit\/s Ethernet ports and an isolated CAN channel support deterministic fieldbus protocols. Robust firmware flash compatibility permits continuous kernel updates and application deployment without interrupting non-volatile memory structures within the 512 KB NVRAM buffer.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the MX220\/2G supply power to adjacent I\/O modules installed on the backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module features an integrated 24 VDC power supply converter that converts primary 18-34 VDC power to regulated backplane rails, providing up to +5 VDC (1700 mA), +15 VDC (30 mA), and -15 VDC (30 mA) directly to attached modules.\u003c\/p\u003e\n\u003cp\u003eQ: What operational safeguards are present on the 24 VDC input terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The primary 24 VDC power input circuit incorporates internal reverse polarity protection and overvoltage clamping to prevent hardware failure in the event of field wiring inversion or supply line transients.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the MX220\/2G vertically into the designated master slot of the M1 base rack, pushing until the module connects firmly with the backplane header. Secure the top and bottom retaining screws to establish chassis ground continuity and lock the assembly against mechanical vibration. Maintain a minimum clearance of 50 mm above and below the housing to facilitate natural convection airflow through the thermal cooling fins.\u003c\/p\u003e\n\u003cp\u003eConnect 24 VDC power lines using wire cross-sections sized according to maximum current draw, ensuring polarity alignment. Connect Ethernet and isolated CAN bus cables using shielded twisted-pair media, terminating cable shields at the panel grounding bus. Set the front-mounted 16-bit rotary switches to the assigned system address prior to powering on the unit.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890699792696,"sku":"MX220\/2G","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/248..jpg?v=1788257274"},{"product_id":"bachmann-mc212-2g-0gb-cfa-mc200-cpu-processor-module","title":"Bachmann MC212-2G\/0GB CFA MC200 CPU processor module","description":"\u003ch2\u003eBachmann MC212-2G\/0GB CFA MC200 CPU Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann MC212-2G\/0GB CFA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC212\u003c\/strong\u003e CPU Processor Module, operates as a dedicated hardware component for deterministic real-time control and high-speed data execution within Bachmann M1 Automation System platforms. Driven by a dual-core Intel Atom CPU at 1.3 GHz with symmetric multiprocessing, the module processes complex motion logic, IEEE 1588 precision time protocols, and internal backplane bus transactions. The fanless unit maintains continuous hardware execution across dual Gigabit Ethernet ports, serial lines, and an integrated CFast slot without requiring active cooling components.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Processor\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOnboard RAM\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStorage Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMC212-2G\/0GB CFA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-core Intel Atom 1.3 GHz\u003c\/td\u003e\n\u003ctd\u003e2 GB DDR4\u003c\/td\u003e\n\u003ctd\u003e2 GB pSLC Flash + CFast Slot (No CFast card included)\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMC212 Base Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-core Intel Atom 1.3 GHz\u003c\/td\u003e\n\u003ctd\u003eScalable RAM\u003c\/td\u003e\n\u003ctd\u003eInternal Flash \/ CFast Options\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC212-2G\/0GB CFA (Base Model: MC212)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 119 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +60 deg C (Fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11.1 W (5 VDC, 2220 mA via backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Unit\u003c\/td\u003e\n\u003ctd\u003eDual-core Intel Atom, 1.3 GHz (x86 architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e2 GB DDR4 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetentive Storage\u003c\/td\u003e\n\u003ctd\u003e512 KB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e2 GB pSLC Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCFast Type I slot (supports up to 256 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003e2 x Gigabit Ethernet (IEEE 1588), 1 x RS232, 1 x RS232\/422\/485, 1 x USB 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity Hardware\u003c\/td\u003e\n\u003ctd\u003eTPM 2.0 Hardware Encryption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe Bachmann MC212-2G\/0GB CFA maximizes backplane bus communication velocity to support microsecond-level synchronization across local and remote I\/O expansion racks. Utilizing core reservation for dedicated real-time tasks, the dual-core architecture eliminates cycle jitter when accessing backplane memory registers. Dual Gigabit Ethernet ports leverage hardware-based IEEE 1588 time stamping to maintain clock precision within +\/-1 us across distributed automation loops. Onboard firmware flash compatibility enables non-disruptive kernel upgrades and runtime data retention inside the 512 KB NVRAM buffer.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the MC212 module handle module power requirements from the backplane rack?\u003c\/p\u003e\n\u003cp\u003eA: The processor draws 5 VDC directly from the M1 backplane bus, consuming approximately 2220 mA (11.1 W) under nominal processing loads. System designers must verify that the central power supply card provides sufficient 5 VDC current headroom for attached I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What memory media options are supported for external application storage and data logging?\u003c\/p\u003e\n\u003cp\u003eA: The front panel incorporates a CFast Type I card slot supporting industrial CFast media up to 256 GB for project backup, data logging, and system firmware updates.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the MC212 module vertically into the master processor slot of the Bachmann M1 base rack. Slide the unit along the guide rails until the backplane multi-pin connector fully engages, then tighten the top and bottom retaining screws to establish chassis ground continuity. Maintain a minimum vertical clearance of 50 mm above and below the enclosure to ensure proper convection cooling through the heat sink assembly.\u003c\/p\u003e\n\u003cp\u003eConnect Ethernet communication cables using industrial-grade shielded CAT6\/CAT7 cables to prevent electromagnetic interference. Set the front-panel 16-bit rotary switches to the assigned node address prior to applying power to the backplane. Ensure the CFast card slot cover remains securely fastened during operation in harsh environments.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52890728038712,"sku":"MC212","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/249.jpg?v=1788257715"},{"product_id":"fs222-n-bachmann-m1-fastbus-slave-fiber-optic-module","title":"FS222\/N BACHMANN M1 FASTBUS Slave Fiber Optic Module","description":"\u003ch2\u003eBACHMANN FS222\/N FASTBUS Slave Fiber Optic Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed deterministic fieldbus extension in Bachmann M1 Automation Systems, the \u003cstrong\u003eBACHMANN FS222\/N\u003c\/strong\u003e (\u003cstrong\u003eFS222\/N\u003c\/strong\u003e FASTBUS Slave Module) provides direct physical\/electrical execution for multi-node industrial network topologies across remote chassis clusters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS222\/N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.70 kg (1.54 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e108 mm x 114 mm x 63 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eIntegrated power supply 17 W output capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18 to 34 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Power Output\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 3000 mA, +15 VDC at 250 mA, -15 VDC at 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface\u003c\/td\u003e\n\u003ctd\u003e2x FO-ports with LC connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Cable Type\u003c\/td\u003e\n\u003ctd\u003e50\/125 um or 62.5\/125 um multi-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eUp to 15 distributed substations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Options\u003c\/td\u003e\n\u003ctd\u003eLC fiber optic, RJ45 patch cable, Harting PushPull plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Scaling \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module integrates directly into the Bachmann backplane bus communication velocity Licences ecosystem, transmitting deterministic FASTBUS protocol packets over long distances with minimal latency. It supports dynamic I\/O density scaling across up to 15 distributed substations without degrading backplane cycle times. Strict firmware flash compatibility controls ensure seamless real-time handshakes between local FASTBUS master controllers and remote slave nodes, maintaining synchronous data frames across isolated multi-mode optical lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary restrictions when wiring the optical ports on the FS222\/N?\u003c\/p\u003e\n\u003cp\u003eA: Engineers must utilize 50\/125 um or 62.5\/125 um multi-mode fiber terminated with LC connectors, ensuring the total point-to-point link length does not exceed 2000 m to prevent excessive optical attenuation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the internal power supply feed expansion I\/O modules directly?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the integrated power section delivers isolated secondary rails (+5 VDC at 3000 mA, +15 VDC at 250 mA, and -15 VDC at 200 mA) up to a 17 W limit directly to adjacent backplane modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit securely onto a standard 35 mm DIN rail or flat panel surface inside an IP54-rated enclosure. Connect the primary 24 VDC power feed to the designated screw terminals while verifying that input supply voltage stays strictly within the 18 to 34 VDC range. Ensure field technicians maintain minimum bend radius limits when routing multi-mode fiber optic cables into the LC ports. Ground all metallic enclosures and shield drain wires directly to the main system earth bar to mitigate high-frequency surge interference.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894338154808,"sku":"FS222\/N","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/251.jpg?v=1788317360"},{"product_id":"dio216-4-bachmann-m1-automation-system-digital-input-output-module","title":"DIO216\/4 BACHMANN M1 Automation System Digital Input Output Module","description":"\u003ch2\u003eBACHMANN DIO216\/4 Digital Input\/Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN DIO216\/4\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDIO216\/4\u003c\/strong\u003e Digital Input\/Output Module, operates as a dedicated hardware component for processing discrete field signals within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDIO216\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.62 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e53 mm x 117 mm x 71 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 18 to 34 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 configurable digital I\/O channels (4 groups, 3-wire system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eHigh: 15 to 34 VDC \/ Low: 0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Delay \/ Resistance\u003c\/td\u003e\n\u003ctd\u003e600 us (typical) filter delay \/ 6.8 kOhm internal resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt Channels\u003c\/td\u003e\n\u003ctd\u003e1 dedicated interrupt input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e18 to 34 VDC \/ Max 1 A per channel (Max 16 A total output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 1 kHz (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Configurable Density\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Bachmann backplane bus communication velocity Licences infrastructure, permitting real-time synchronization across high-density I\/O arrays. Dynamic I\/O density scaling allows each of the 16 channels to be configured as either an input or an output across 4 independent isolated channel groups. Firmware flash compatibility checks execute during boot to verify control cycle timing, ensuring zero data loss during high-frequency switching operations up to 1 kHz.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power limits must be observed for the digital output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel handles a maximum continuous load of 1 A at 18 to 34 VDC, with the total cumulative current across all 16 channels limited to 16 A.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module process rapid input state transitions?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates a 600 us digital filter delay to eliminate contact bounce and includes 1 dedicated interrupt input channel for direct event triggering.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit on a standard 35 mm DIN rail or secure it directly to a grounded backplate inside an IP54-rated industrial control cabinet. Connect the primary supply lines to the 18-34 VDC power terminals, verifying correct wire polarity before energizing. Route signal conductors through a proper 3-wire wiring system, keeping signal wires separated from high-voltage motor or drive cables to prevent electromagnetic coupling. Connect all cable shields to the main functional earth (FE) bus bar using low-impedance grounding clamps.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894348509496,"sku":"DIO216\/4","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/252..jpg?v=1788317816"},{"product_id":"mc206-bachmann-m1-automation-system-intel-atom-cpu-module","title":"MC206 BACHMANN M1 Automation System Intel Atom CPU Module","description":"\u003ch2\u003eBACHMANN MC206 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN MC206\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC206\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for deterministic real-time processing and communication execution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 119 mm x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.3 W typical (+5 VDC via M1 backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom single-core 600 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB DDR4 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemanent Memory\u003c\/td\u003e\n\u003ctd\u003e512 kB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e2 GB pSLC Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCFast Type I slot (supports up to 256 GB tested)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet 10\/100\/1000 Base-T, 1x RS232, 1x RS232\/422\/485, 1x USB 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 precision clock synchronization (+\/- 1 us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity \u0026amp; Protection\u003c\/td\u003e\n\u003ctd\u003eTPM 2.0 hardware module, IP20 rating, conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Performance \u0026amp; Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe central processing unit manages deterministic task execution across the backplane bus communication velocity Licences framework, preventing latency jitter during high-speed control cycles. Multi-protocol fieldbus integration scales I\/O density scaling efficiently over the dual Gigabit Ethernet links with hardware-level IEEE 1588 clock synchronization (+\/- 1 us accuracy). Strict firmware flash compatibility validation guards backplane communication frames against execution anomalies during industrial real-time controller cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is retain memory preserved in the event of a total supply voltage interruption?\u003c\/p\u003e\n\u003cp\u003eA: Non-volatile configuration variables and critical process parameters register instantly to the integrated 512 kB NVRAM without requiring battery backup.\u003c\/p\u003e\n\u003cp\u003eQ: Can the serial interface parameters be modified in software?\u003c\/p\u003e\n\u003cp\u003eA: The second serial port supports software configuration for RS232, RS422, or RS485 physical signal levels to interface directly with field instrumentation.\u003c\/p\u003e\n\u003cp\u003eQ: What cooling provisions are necessary inside the control cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on fanless passive cooling with conformal-coated electronics; it requires standard free-convection airflow within an operating environment maintained between -30 deg C and +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the CPU module vertically on a standard 35 mm DIN rail or panel surface within an IP54-rated industrial cabinet to ensure sufficient heat dissipation through passive convection. Verify that backplane power supply connections to the +5 VDC bus remain stable before locking the module into position. Ensure all Ethernet network drop cables utilize shielded twisted pair (STP) construction with grounded metallic RJ45 connectors. Connect the enclosure ground conductor directly to the primary cabinet ground point using a low-impedance grounding strap to prevent electrostatic discharge.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894363124024,"sku":"MC206","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/253.jpg?v=1788318717"},{"product_id":"intel-atom-cpu-module-mc210-bachmann-m1","title":"Intel Atom CPU Module | MC210 BACHMANN M1","description":"\u003ch2\u003eBACHMANN MC210 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN MC210\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC210\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for deterministic real-time processing and fieldbus control execution within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 119 mm x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11.2 W typical (+5 VDC via M1 backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E680 \/ Dual-Core Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB DRAM \/ 2 GB DDR4 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemanent Memory\u003c\/td\u003e\n\u003ctd\u003e512 kB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e64 MB Flash \/ 4 GB pSLC Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003e1x CFast Type I slot (supports up to 256 GB tested)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet 10\/100\/1000 Base-T (IEEE 1588), 1x RS232, 1x RS232\/422\/485, 1x USB Host, 1x USB Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 precision clock synchronization (+\/- 1 us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity \u0026amp; Protection\u003c\/td\u003e\n\u003ctd\u003eTPM 2.0 hardware module, IP20 rating, conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Scaling \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe processor module interfaces directly with the backplane bus communication velocity Licences framework, driving deterministic control execution across local and remote node configurations. Dynamic I\/O density scaling allows complex multi-channel modules to operate at high scan rates over dual Gigabit Ethernet links with hardware-level IEEE 1588 synchronization. Integrated firmware flash compatibility verification routines continuously validate backplane telegram exchange, maintaining execution stability without latency jitter across industrial networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle non-volatile data storage during power interruption events?\u003c\/p\u003e\n\u003cp\u003eA: Critical runtime variables register immediately to the onboard 512 kB NVRAM retain memory without requiring maintenance-intensive battery buffers.\u003c\/p\u003e\n\u003cp\u003eQ: Can the secondary serial port be modified for differential communication standards?\u003c\/p\u003e\n\u003cp\u003eA: The second serial interface supports software selection between RS232, RS422, and RS485 modes to accommodate diverse field devices.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental precautions apply to cabinet placement?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on fanless passive convection cooling with conformal coating; install technicians must ensure free ambient air movement inside enclosures maintained within -30 deg C to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the processor unit vertically on a standard 35 mm DIN rail or mounting plate inside an IP54 enclosure, maintaining at least 50 mm clearance above and below for passive thermal dissipation. Verify backplane bus connections and ensure +5 VDC power rails are de-energized prior to inserting the unit into the chassis. Connect all network drops using shielded twisted-pair (STP) Ethernet cables with metal-shielded RJ45 plugs. Ground all cable shields directly to the main functional earth (FE) bus bar using low-impedance grounding clamps.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894396023096,"sku":"MC210","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/254..jpg?v=1788318859"},{"product_id":"fm212-bachmann-m1-fastbus-master-fiber-optic-module","title":"FM212 BACHMANN M1 FASTBUS Master Fiber Optic Module","description":"\u003ch2\u003eBACHMANN FM212 FASTBUS Master Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN FM212\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFM212\u003c\/strong\u003e FASTBUS Master Module, operates as a dedicated hardware component for central communication control and deterministic data exchange within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFM212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58 mm x 51 mm x 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC M1 backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Role\u003c\/td\u003e\n\u003ctd\u003eFASTBUS master for up to 15 substations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Medium\u003c\/td\u003e\n\u003ctd\u003eFiber optic (multimode 50\/125 um or 62.5\/125 um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Range\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m between stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eLC fiber optic connector, RJ45 patch cable, Harting PushPull plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eStar or line topology configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Scaling \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe master controller manages fieldbus traffic using the backplane bus communication velocity Licences protocol to ensure low-latency frame distribution across connected optical nodes. High-density I\/O density scaling allows synchronized processing across up to 15 distributed substations over fiber optic lines spanning distances up to 2000 m. Strict firmware flash compatibility rules ensure cyclic packet integrity during real-time control operations over both line and star topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many remote substations can a single master module control simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: The hardware supports centralized deterministic communication management for up to 15 remote FASTBUS slave substations.\u003c\/p\u003e\n\u003cp\u003eQ: What optical media types are compatible with the integrated LC interface ports?\u003c\/p\u003e\n\u003cp\u003eA: The transceiver accepts standard 50\/125 um or 62.5\/125 um multimode fiber optic cables for transmission distances up to 2000 m.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a standard 35 mm DIN rail or secure panel surface within an IP54 enclosure, verifying proper seating into the M1 backplane rack. De-energize the 24 VDC primary power supply before inserting or removing the unit to prevent backplane edge connector damage. Clean optical LC connector faces before inserting multimode fiber optic cables, ensuring engineers observe minimum cable bend radius limits during routing. Ground all metal enclosure components directly to the main system earth bar using low-impedance grounding straps.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894405460280,"sku":"FM212","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/255._b6251b55-ad96-4aef-9835-d02fd0358a7c.jpg?v=1788319485"},{"product_id":"bachmann-mc205-m1-automation-system-intel-atom-cpu-module","title":"BACHMANN MC205 M1 Automation System Intel Atom CPU Module","description":"\u003ch2\u003eBACHMANN MC205 CPU Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic real-time control and process execution in Bachmann M1 Automation Systems, the \u003cstrong\u003eBACHMANN MC205\u003c\/strong\u003e (\u003cstrong\u003eMC205\u003c\/strong\u003e CPU Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg (1.21 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 53 mm x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W typical (+5 VDC via M1 backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E620 single-core (500 MHz to 600 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB DRAM \/ DDR2 RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemanent Memory\u003c\/td\u003e\n\u003ctd\u003e512 kB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Storage\u003c\/td\u003e\n\u003ctd\u003e64 MB Flash (40 MB free for application) \/ 2 GB pSLC Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003e1x CFast Type I slot (\u0026gt; 8 GB, up to 256 GB tested)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet 10\/100\/1000 Base-T (IEEE 1588), 1x RS232, 1x RS232\/422\/485, 1x USB Host, 1x USB Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Features\u003c\/td\u003e\n\u003ctd\u003eHardware watchdog, battery-backed RTC, 3x status LEDs, rotary hexadecimal switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Isolation\u003c\/td\u003e\n\u003ctd\u003eIP20, Class III electrical safety, conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Control \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe central processing unit operates on the VxWorks real-time operating system with Bachmann system extensions, interfacing directly with the backplane bus communication velocity Licences framework. High-speed process image transfer enables dynamic I\/O density scaling across backplane modules without control cycle degradation. Network-wide frame alignment occurs through hardware-based IEEE 1588 clock synchronization across Ethernet networks and integrated SERCOS, CAN, and backplane I\/O buses. Integrated firmware flash compatibility validation enforces real-time synchronization integrity across distributed automation topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the hardware CPU node address configured on the module?\u003c\/p\u003e\n\u003cp\u003eA: Field engineers set the unique CPU ID directly via physical rotary hexadecimal switches located on the front panel of the hardware housing.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms preserve critical program variables during power loss?\u003c\/p\u003e\n\u003cp\u003eA: Real-time process values instantly copy to the non-volatile 512 kB NVRAM memory array, while the system real-time clock maintains timekeeping using an onboard battery circuit.\u003c\/p\u003e\n\u003cp\u003eQ: Are the integrated serial interfaces individually software-configurable?\u003c\/p\u003e\n\u003cp\u003eA: The module contains one dedicated RS232 interface and a second serial port that engineers can configure via software for RS232, RS422, or RS485 physical signal levels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the processor module vertically onto a standard 35 mm DIN rail inside an IP54-rated control cabinet to allow proper thermal air circulation through the passive heatsink structure. De-energize all primary 24 VDC power lines supplying the backplane rack prior to inserting or removing the module. Connect network drops using double-shielded twisted-pair Ethernet cables with metal-shielded RJ45 plugs. Bond all cable drain wires directly to the main functional earth (FE) bus bar using low-impedance grounding clamps to prevent high-frequency field interference.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894412898616,"sku":"MC205","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/256_0618bb98-c7ae-4d0e-949e-75173b556356.jpg?v=1788319704"},{"product_id":"dpm200-bachmann-m1-profibus-dp-master-slave-module","title":"DPM200 BACHMANN M1 PROFIBUS DP Master Slave Module","description":"\u003ch2\u003eBACHMANN DPM200 PROFIBUS DP Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN DPM200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDPM200\u003c\/strong\u003e PROFIBUS DP Module, operates as a dedicated hardware component for deterministic fieldbus data exchange within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDPM200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 22 mm x 118 mm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e400 mA at 5 VDC via backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eDP Master, DP Slave, combined Master\/Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Modules per CPU\u003c\/td\u003e\n\u003ctd\u003eUp to 3 DPM200 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlave Capacity\u003c\/td\u003e\n\u003ctd\u003e32 without repeater, up to 125 with repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaud Rate Range\u003c\/td\u003e\n\u003ctd\u003e9.6 Kbaud to 12 Mbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003e2x 9-pin D-sub connectors (EN 50170 standard, RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V galvanic isolation between fieldbus and controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e8 kB shared process image memory, up to 732 bytes per slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Scaling \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module routes high-speed cyclically updating field data directly through the backplane bus communication velocity Licences layer, enabling real-time logic execution without system bottlenecks. Configurable hardware consistency locks preserve data block alignment during multi-byte transfers between distributed field devices and the host CPU memory. High-density I\/O density scaling allows control architectures to expand up to 125 slaves per master controller using external RS485 repeaters. Engineers execute online updates directly via the Bachmann SolutionCenter environment to maintain full firmware flash compatibility across backplane processing nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle memory allocation for high-density field data?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates an 8 kB shared process image memory architecture that supports data exchanges up to 732 bytes per individual slave device.\u003c\/p\u003e\n\u003cp\u003eQ: What power draw does the module impose on the M1 backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The card draws a nominal current of 400 mA from the internal 5 VDC logic supply rails of the controller backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple DPM200 modules reside within a single M1 system configuration?\u003c\/p\u003e\n\u003cp\u003eA: A single Bachmann M1 controller platform supports simultaneous operation for up to 3 DPM200 master\/slave expansion units.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module into an assigned backplane slot of the Bachmann M1 rack, ensuring complete mechanical lock engagement prior to applying system power. De-energize the host cabinet power supply before inserting or extracting the module to protect internal edge connector pins. Fasten standard 9-pin D-sub connectors firmly to the front panel interface ports using integrated locking screws to ensure continuous ground contact along the RS485 shield plane. Maintain strict separation between high-voltage power cables and fieldbus signal lines, using grounded metal conduit when routing fieldbus cables across long physical runs.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894432133432,"sku":"DPM200","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/257._cf9fbbc2-1592-4833-bd6e-3baaf922ad8e.jpg?v=1788320074"},{"product_id":"bachmann-cnt204-r-cnt204-m1-guard-plc-counter-module","title":"BACHMANN CNT204\/R CNT204 M1 Guard PLC Counter Module","description":"\u003ch2\u003eBACHMANN CNT204\/R Counter Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN CNT204\/R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCNT204\u003c\/strong\u003e Counter Module, operates as a dedicated hardware component for processing incremental encoder signals, measuring frequencies, and counting pulses within Bachmann M1 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCNT204\/R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 25 mm x 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC M1 backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Channels\u003c\/td\u003e\n\u003ctd\u003e4 independent counter channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Modes\u003c\/td\u003e\n\u003ctd\u003eUp\/down counter, frequency measurement, period measurement, event counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eIncremental encoder signals (A\/B), pulse trains, digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 VDC to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 1 MHz (mode dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporal Resolution\u003c\/td\u003e\n\u003ctd\u003e42 ns for period and differential measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounter Resolution\u003c\/td\u003e\n\u003ctd\u003e32-bit per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V between field and logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic High-Speed Processing \u0026amp; Backplane Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe module channels high-frequency pulse trains directly into the backplane bus communication velocity Licences protocol, eliminating signal acquisition delays across the central processor. Real-time hardware latches perform edge-triggered data captures with a 42 ns temporal resolution, providing accurate period and phase shift measurement across all active channels. Integrated I\/O density scaling allows complex multi-axis encoder feedback systems to operate concurrently without overloading backplane bandwidth. Internal diagnostics monitor both logic supply rails and field-side initiator voltages to maintain total firmware flash compatibility during continuous high-speed counting.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the hardware handle input signal isolation between the field sensors and the logic bus?\u003c\/p\u003e\n\u003cp\u003eA: Integrated optical isolators establish 500 V galvanic isolation between the field-side input circuitry and the internal controller backplane logic.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module supply power directly to connected incremental encoders?\u003c\/p\u003e\n\u003cp\u003eA: The module features integrated encoder power delivery outputs located directly on the front field terminal connectors.\u003c\/p\u003e\n\u003cp\u003eQ: How are high-speed position events captured without CPU polling overhead?\u003c\/p\u003e\n\u003cp\u003eA: Each counter channel incorporates a dedicated 32-bit hardware latch function that captures counter values instantaneously upon receiving an external trigger signal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit directly onto the M1 backplane rail within a grounded NEMA or IP54-rated metal enclosure. De-energize the main 24 VDC power feed prior to inserting or removing the module to prevent electrical arcing across backplane bus contacts. Route incremental encoder and high-frequency pulse lines using individually shielded twisted-pair cables. Clamp cable shields directly to the cabinet ground bar using low-impedance grounding clips, maintaining maximum physical separation between signal wiring and high-voltage AC motor drives.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52894441046328,"sku":"CNT204","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/258._39d6b463-28ff-4b85-a1d9-170f23c7840d.jpg?v=1788320802"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/collections\/Bachmann_Electronic_GmbH_Products.png?v=1723022699","url":"https:\/\/www.automodulexpert.com\/collections\/bachmann.oembed?page=5","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}