{"title":"GE MultiLin","description":"\u003cp\u003eGE MultiLin is an industrial networking solution from GE designed to connect various automation devices and ensure high-speed, reliable data transmission. The MultiLin product line includes several models to meet different application needs, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Modules\u003c\/strong\u003e: Digital and analog connections for field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Modules\u003c\/strong\u003e: Interfaces for network connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGateway Modules\u003c\/strong\u003e: Connect different network types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","products":[{"product_id":"ge-fanuc-multilin-ur-rhh-power-supply-module-ur-rhh","title":"GE FANUC Multilin UR RHH Power Supply Module UR-RHH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e The UR-RHH by General Electric is a power supply module designed for the Universal Relays series. It is available in two voltage ranges, with an option for redundant power capability. The Low Range (LO) operates on 24 to 48 V DC, while the High Range (HI) supports 125 to 250 V, accommodating both DC and AC. This module provides power to the relay and also powers dry contact input connections. \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVoltage Ranges:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLow Range (LO):\u003c\/strong\u003e 24 to 48 V nominal (DC)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHigh Range (HI):\u003c\/strong\u003e 125 to 250 V nominal (DC and AC)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRedundant Power Option:\u003c\/strong\u003e Available upon request\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInternal Fuse Rating:\u003c\/strong\u003e 4A\/250 V\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturing Location:\u003c\/strong\u003e Markham, Ontario, Canada\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 2 lb, 2 oz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 6.5\" L x 6.5\" W x 1.75\" H\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e Works seamlessly with EnerVista UR software for comprehensive management and monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49155154051384,"sku":"UR RHH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/685633d4209645e35ad5ceece89b64f1.jpg?v=1724384058"},{"product_id":"ge-fanuc-ur-9eh-multilin-central-processing-unit-ur-9eh","title":"GE FANUC UR 9EH Multilin Central Processing Unit UR-9EH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe General Electric Multilin UR-9EH is a CPU module designed for replacing a faulty unit or upgrading an existing module within the Universal Relays series. This module powers the relay by managing logic algorithms, logic gates, latches, and timers, and notably, it does not require a surge ground connection.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWhen installing a new CPU module, it is crucial to pair it with a corresponding new CT\/VT module; similarly, an older CPU module must be used with an older CT\/VT module. Ignoring this compatibility will trigger errors such as HARDWARE MISMATCH or DSP ERROR. Therefore, users should carefully select the appropriate module to match the age and type of their existing components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 1 lb, 10 oz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 6.5\" L x 6\" W x 2.5\" H\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49155443392824,"sku":"UR 9EH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/240a450b110f146d71fd602453a88848.jpg?v=1724392507"},{"product_id":"ge-fanuc-sr469-p5-hi-a20-multilin-motor-management-relay","title":"GE FANUC SR469-P5-HI-A20 Multilin Motor Management Relay","description":"\u003ch3\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e The 469 Motor Management Relay is a microprocessor-based device designed to protect and manage medium to large horsepower motors and their associated equipment. This relay features six output relays, which are used for tripping, alarms, and start blocking. It combines motor protection, fault diagnostics, power metering, and RTU (Remote Terminal Unit) functions into a single, cost-effective, drawout package. The following single-line diagram demonstrates the 469's functionality, using ANSI (American National Standards Institute) device numbers for reference. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eANALOG CURRENT INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e: 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA (settings)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput impedance\u003c\/strong\u003e: 226 Ω ±10%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion range\u003c\/strong\u003e: 0 to 21 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% of full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Passive\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAnalog in supply\u003c\/strong\u003e: +24 V DC at 100 mA max.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e: ≤100 ms\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDIFFERENTIAL CURRENT INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT secondary\u003c\/strong\u003e: 1 A or 5 A (settings)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e: \u0026lt;0.2 VA at rated load\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion range\u003c\/strong\u003e: 0.02 to 1 × CT primary\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNominal frequency\u003c\/strong\u003e: 20 to 70 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e: 20 to 120 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.5% of 1 × CT for 5 A; ±0.5% of 5 × CT for 1 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT withstand\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e1 second at 80 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e2 seconds at 40 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eContinuous at 3 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDIGITAL INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e: 9 opto-isolated inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eExternal switch\u003c\/strong\u003e: Dry contact \u0026lt; 400 Ω, or open collector NPN transistor from sensor; 6 mA sinking from internal 4 KΩ pull-up at 24 V DC with Vce \u0026lt; 4 V DC\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGROUND CURRENT INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT secondary\u003c\/strong\u003e: 1 A or 5 A (settings)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e: \u0026lt;0.2 VA at rated load for 1 A or 5 A; \u0026lt;0.25 VA for 50:0.025 CTs at 25 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion range\u003c\/strong\u003e: 0.02 to 1 × CT primary\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNominal frequency\u003c\/strong\u003e: 20 to 70 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e: 20 to 120 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e±0.5% of 1 × CT for 5 A CTs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e±0.5% of 5 × CT for 1 A CTs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e±0.125 A for 50:0.025 CTs\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT (1 A\/5 A) withstand\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e1 second at 80 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e2 seconds at 40 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eContinuous at 3 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT (50:0.025) withstand\u003c\/strong\u003e: Continuous at 150 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePHASE CURRENT INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT secondary\u003c\/strong\u003e: 1 A or 5 A (specify with order)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e: Less than 0.2 VA at rated load\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion range\u003c\/strong\u003e: 0.05 to 20 × CT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNominal frequency\u003c\/strong\u003e: 20 to 70 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e: 20 to 120 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eAt \u0026lt; 2 × CT: ±0.5% of 2 × CT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eAt ≥ 2 × CT: ±1% of 20 × CT\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT withstand\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e1 second at 80 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e2 seconds at 40 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eContinuous at 3 × rated current\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRTD INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e3 wire RTD Types\u003c\/strong\u003e: 100 Ω Platinum (DIN.43760), 100 Ω Nickel, 120 Ω Nickel, 10 Ω Copper\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRTD sensing current\u003c\/strong\u003e: 5 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 36 Vpk (isolated with analog inputs and outputs)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e: –50 to +250°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±2°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLead resistance\u003c\/strong\u003e: 25 Ω Max per lead for Pt and Ni type; 3 Ω Max per lead for Cu type\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNo sensor\u003c\/strong\u003e: \u0026gt;1000 Ω\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eShort\/low alarm\u003c\/strong\u003e: \u0026lt;–50°C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTRIP COIL SUPERVISION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eApplicable voltage\u003c\/strong\u003e: 20 to 300 V DC \/ V AC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTrickle current\u003c\/strong\u003e: 2 to 5 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVOLTAGE INPUTS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVT ratio\u003c\/strong\u003e: 1.00 to 300.00:1 in steps of 0.01\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVT secondary\u003c\/strong\u003e: 273 V AC (full-scale)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion range\u003c\/strong\u003e: 0.05 to 1.00 × full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNominal frequency\u003c\/strong\u003e: 20 to 70 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e: 20 to 120 Hz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.5% of full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMax. continuous\u003c\/strong\u003e: 280 V AC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e: \u0026gt;500 kΩ\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSensor supply\u003c\/strong\u003e: +24 V DC at 20 mA max.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eANALOG CURRENT OUTPUT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Active\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e: 4 to 20 mA, 0 to 1 mA (must be specified with order)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% of full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMax. load\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e4 to 20 mA input: 1200 Ω\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e0 to 1 mA input: 10 kΩ\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 36 Vpk (isolated with RTDs and analog inputs)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e4 Assignable Outputs\u003c\/strong\u003e:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003ePhase A, B, and C current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eThree-phase average current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eGround current\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003ePhase AN (AB), BN (BC), and CN (CA) voltages\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eThree-phase average voltage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eHottest stator RTD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eHottest bearing RTD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eHottest other RTD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eRTDs 1 to 12\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCASE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Fully drawout (automatic CT shorts)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSeal\u003c\/strong\u003e: Seal provision\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Panel or 19-inch rack mount\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIP Class\u003c\/strong\u003e: IP40-X\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePACKAGING\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eShipping box\u003c\/strong\u003e: 12” × 11” × 10” (W × H × D) \/ 30.5 cm × 27.9 cm × 25.4 cm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e: 17 lbs Max \/ 7.7 kg\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eENVIRONMENT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e: –40°C to +60°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAmbient storage temperature\u003c\/strong\u003e: –40°C to +80°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: Up to 90%, non-condensing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e: Up to 2000 m\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e: 2\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49155622207800,"sku":"SR469-P5-HI-A20","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/06ac2597c20e0a55149aaa6f8b6f47c6.jpg?v=1724396362"},{"product_id":"ge-fanuc-369-hi-r-m-0-0-0-e-multilin-motor-management-relay","title":"GE FANUC 369-HI-R-M-0-0-0-E Multilin Motor Management Relay","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe 369 Motor Management Relay is an advanced digital relay designed to protect and monitor three-phase motors and their related mechanical systems. One of its standout features is the ability to \"learn\" specific motor parameters and adapt to individual applications. By analyzing values like motor inrush current, cooling rates, and acceleration time, the 369 Relay enhances its protective functions, offering tailored and efficient motor protection.\u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCONTROL POWER\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLO Range:\u003c\/strong\u003e\u003c\/span\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDC: 20 to 60 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAC: 20 to 48 V AC at 50\/60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHI Range:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDC: 50 to 300 V DC\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAC: 60 to 265 V AC at 50\/60 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eNominal: 20 VA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMaximum: 65 VA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHoldup:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eNon-failsafe trip: 200 ms\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFailsafe trip: 100 ms\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFUSE\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType:\u003c\/strong\u003e T 3.15 A H 250 V (5 × 20 mm)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e Timelag high breaking capacity\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePHASE CURRENT INPUTS (CT)\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT Input (Rated):\u003c\/strong\u003e 1 A and 5 A secondary\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT Primary:\u003c\/strong\u003e 1 to 5000 A\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 50\/60 Hz nominal frequency: 0.05 to 20 × CT primary amps\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor variable frequency: 0.1 to 20 × CT primary amps\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFull Scale:\u003c\/strong\u003e 20 × CT primary amps or 65535 A maximum\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 20 to 100 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion:\u003c\/strong\u003e True RMS, 1.04 ms\/sample\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAt ≤ 2 × CT:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±0.5% of 2 × CT for 50\/60 Hz nominal frequency\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±1.0% of 2 × CT for variable frequency (for sinusoidal waveforms)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAt \u0026gt; 2 × CT:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±1.0% of 20 × CT for 50\/60 Hz nominal frequency\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±3.0% of 12 × CT or less for variable frequency (for sinusoidal waveforms)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDIGITAL \/ SWITCH INPUTS\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 6 optically isolated\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e Dry Contact (\u0026lt; 800 Ω)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Programmable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGROUND CURRENT INPUT (GF CT)\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT Input (Rated):\u003c\/strong\u003e 1 A\/5 A secondary and 50:0.025\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCT Primary:\u003c\/strong\u003e 1 to 5000 A (1 A\/5 A)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0.1 to 1.0 × CT primary (1 A\/5 A)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e0.05 to 25.0 A (50:0.025)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFull Scale:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e1.0 × CT primary (1 A\/5 A)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e25 A (50:0.025)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 20 to 100 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion:\u003c\/strong\u003e True RMS 1.04 ms\/sample\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy at 50\/60 Hz:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 1 A\/5 A: ±1.0% of full scale (1 A\/5 A)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 50:0.025: ±0.07 A at \u0026lt;1 A, ±0.20 A at \u0026lt;25 A\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy at Variable Frequency:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 1 A Tap:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±1.5% for 40 to 100 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±2.5% for 20 to 39 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 5 A Tap:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±2% for 40 to 100 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±3% for 20 to 39 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eFor 50:0.025:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±0.2 A at \u0026lt;1 A\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±0.6 A at \u0026lt;25 A\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePHASE\/LINE VOLTAGE INPUT (VT) (OPTION M)\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVT Ratio:\u003c\/strong\u003e 1.00 to 240.00:1 in steps of 0.01\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVT Secondary:\u003c\/strong\u003e 240 V AC (full scale)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e 0.05 to 1.00 × full scale\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 20 to 100 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eConversion:\u003c\/strong\u003e True RMS 1.04 ms\/sample\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±2.5% of full scale for ≤ 200 V at 20 to 39 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e±1% of full scale for 12 to 240 V at \u0026gt; 40 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e \u0026gt;200 kΩ\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eMax. Continuous:\u003c\/strong\u003e 280 V AC\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBSD INPUTS (OPTION B)\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 1 to 120 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDynamic BSD Range:\u003c\/strong\u003e 20 mV to 480 V RMS\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.02 Hz\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e \u0026gt;200 kΩ\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRTD INPUTS (OPTION R)\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWire Type:\u003c\/strong\u003e 3 wire\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSensor Type:\u003c\/strong\u003e 100 Ω platinum (DIN 43760), 100 Ω nickel, 120 Ω nickel, 10 Ω copper\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRTD Sensing Current:\u003c\/strong\u003e 3 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eRange:\u003c\/strong\u003e –40 to 200°C or –40 to 392°F\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2°C or ±4°F\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLead Resistance:\u003c\/strong\u003e 25 Ω max. per lead for Pt and Ni type; 3 Ω max. per lead for Cu type\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e 36 Vpk\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAMBIENT TEMPERATURE\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Range:\u003c\/strong\u003e –40°C to +60°C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage Range:\u003c\/strong\u003e –40°C to +80°C\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eT-Code Rating:\u003c\/strong\u003e T4A (for MOD 502 only)\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For 369 units with the Profibus, Modbus\/TCP, or DeviceNet option:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Range:\u003c\/strong\u003e +5°C to +60°C\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eStorage Range:\u003c\/strong\u003e +5°C to +80°C\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHUMIDITY\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e Up to 95% non-condensing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDUST\/MOISTURE\u003c\/strong\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e IP50\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49155674407224,"sku":"369-HI-R-M-0-0-0-E","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/2c8e897b038b230f80dcccb7e7e5b37a.jpg?v=1724397207"},{"product_id":"ge-fanuc-ur-6nh-multilin-digital-i-o-module","title":"GE FANUC UR 6NH Multilin Digital I\/O Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE \u003cstrong\u003eUR 6NH\u003c\/strong\u003e is a part of the Universal Relay (UR) family from General Electric, designed for comprehensive protection, control, and monitoring of power systems. The UR series is typically used for managing critical power protection functions in industrial and utility applications.\u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e: 4 Form-A (current with optional voltage) outputs.\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e: 8 contact inputs.\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eActivation Speed\u003c\/strong\u003e: Less than 4 milliseconds for digital outputs.\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49275451638072,"sku":"UR 6NH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/0e29088487c72ea3eaaaf497a9d42b8f.jpg?v=1727090483"},{"product_id":"ge-fanuc-ur-8lh-multilin-ct-vt-module","title":"GE FANUC UR 8LH Multilin CT\/VT Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eGE UR-8LH\u003c\/strong\u003e is a module designed for the Universal Relay (UR) series of GE's protection and control systems. These systems are typically used in industrial and utility applications for protecting and monitoring electrical power systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLength: Approximately 6 inches\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWidth: Approximately 7 inches\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e2 pounds, 9 ounces\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSupports high-speed communications\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eExtensive programming and configuration capabilities\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49275455504696,"sku":"UR 8LH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/a0b8ba88846227bf6cc214560596ed8f.jpg?v=1727090658"},{"product_id":"ge-fanuc-ur6lv-ur-6lv-ur-6lv-multilin-digital-input-module","title":"GE FANUC UR6LV | UR 6LV | UR-6LV | Multilin Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE FANUC\u003cstrong\u003e UR6LV\u003c\/strong\u003e is a sophisticated Multilin Digital Input Module designed for reliable performance in industrial applications. This module provides enhanced monitoring and control capabilities, making it suitable for various automation tasks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eUR6LV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Multilin Digital Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Industrial automation, process control, system monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eStorage: -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 150 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 100 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.2 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN rail mountable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49296839344440,"sku":"UR6LV","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6LV.jpg?v=1727605668"},{"product_id":"ge-fanuc-ur9nv-ur-9nv-ur-9nv-multilin-cpu","title":"GE FANUC UR9NV | UR 9NV  | UR-9NV | Multilin CPU","description":"\u003ch3\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE FANUC UR9NV\u003c\/strong\u003e is a robust Multilin CPU designed for advanced automation and control applications. Its high processing power ensures efficient data handling and real-time control for critical industrial processes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eUR9NV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Multilin CPU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Automation systems, process monitoring, control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Type:\u003c\/strong\u003e 32-bit microprocessor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock Speed:\u003c\/strong\u003e 1 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRAM: 512 MB\u003c\/li\u003e\n\u003cli\u003eFlash: 1 GB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2 x Ethernet\u003c\/li\u003e\n\u003cli\u003e1 x RS-232\u003c\/li\u003e\n\u003cli\u003e1 x RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eStorage: -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 200 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 120 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 50 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN rail mountable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49296845406520,"sku":"UR9NV","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR9NV.jpg?v=1727605920"},{"product_id":"ge-fanuc-ur8lv-ur-8lv-multilin-ct-vt","title":"GE FANUC UR8LV UR 8LV Multilin CT\/VT","description":"\u003ch3\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE FANUC UR8LV\u003c\/strong\u003e is a high-performance Multilin CT\/VT module designed for effective measurement and monitoring of current and voltage in power systems. Its reliable design ensures accurate data collection for enhanced system protection and control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eUR8LV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Multilin CT\/VT Module\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 120V AC to 480V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e 1A to 5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurden Rating:\u003c\/strong\u003e 1 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eStorage: -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 180 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 100 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.0 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Type:\u003c\/strong\u003e DIN rail mountable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49296848912696,"sku":"UR8LV","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8LV.jpg?v=1727606049"},{"product_id":"ge-fanuc-ur7cm-ur-7cm-ur-7cm-multilin-comms","title":"GE FANUC UR7CM | UR 7CM | UR-7CM Multilin Comms","description":"\u003ch3\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE FANUC UR7CM\u003c\/strong\u003e is a versatile Multilin Comms module designed to facilitate seamless communication between various devices in automation systems. Its robust connectivity options enhance data exchange and system integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Information:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eUR7CM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Multilin Comms Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Data communication, system integration, industrial automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eModbus RTU\u003c\/li\u003e\n\u003cli\u003eDNP3\u003c\/li\u003e\n\u003cli\u003eIEC 61850\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e2 x Ethernet\u003c\/li\u003e\n\u003cli\u003e1 x RS-232\u003c\/li\u003e\n\u003cli\u003e1 x RS-485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003eStorage: -40°C to +85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 180 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 100 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 50 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49296853172536,"sku":"UR7CM","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR7CM.jpg?v=1727606192"},{"product_id":"ge-fanuc-ur7hh-comms-module-ur-7hh","title":"GE FANUC UR7HH COMMS Module UR 7HH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE UR-7HH is a Communication Module designed for use with the UR Series of Multilin Universal Relay Systems. It provides two channels for inter-relay communication, enhancing the relay system's communication capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: 2 LED channels\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e: 820 nm\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Designed for the UR Series of Multilin Universal Relay Systems\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353025651000,"sku":"UR 7HH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/38fa7c692bfe161b4a6a5d91c5bd506e.jpg?v=1729245277"},{"product_id":"ge-fanuc-ursha-power-supply-module-ur-sha","title":"GE FANUC URSHA Power Supply Module UR SHA","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eGE UR-SHA\u003c\/strong\u003e is a Power Supply Module.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eDesigned for use with the \u003cstrong\u003eUR Series\u003c\/strong\u003e of Multilin Universal Relay Systems.\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eEnsures a reliable power source for consistent performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 6.5 inches x 6.5 inches x 1.75 inches (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs, 2 oz (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVoltage Output:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353032859960,"sku":"UR SHA","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/035782ad6ade919eab5774e643dd784b.jpg?v=1729245384"},{"product_id":"ge-fanuc-ur9ah-control-processor-unit-module-ur-9ah","title":"GE FANUC UR9AH Control Processor Unit Module UR 9AH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eGE UR-9AH\u003c\/strong\u003e is a CPU Module designed for use with the UR Series of Multilin Universal Relay Systems. It provides the relay with advanced capabilities such as:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLogic algorithms\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLogic gates\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTimers\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLatches\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThis enables seamless interfacing with other relay modules.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 15 cm x 18 cm x 4 cm (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs, 9 oz (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353046098232,"sku":"UR 9AH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/a3c93f436e9638a3d75d28df21e45611.jpg?v=1729245607"},{"product_id":"ge-fanuc-ur8ch-ct-vt-module-ur-8ch","title":"GE FANUC UR8CH CT\/VT Module UR 8CH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eGE UR-8CH\u003c\/strong\u003e is a CT\/VT Module designed for use in the UR Series of Multilin Universal Relay Systems. It enhances the relay's measurement capabilities by providing:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e3\u003c\/strong\u003e Phase Current Transformers (CTs): 1A\/5A\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e1\u003c\/strong\u003e Ground CT: 1\/5A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 6 inches L x 7 inches W x 1.5 inches H\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353051636024,"sku":"UR 8CH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ca26223925a95d550f5dc3934f593c96.jpg?v=1729245749"},{"product_id":"ge-fanuc-ur6uh-digital-i-o-module-ur-6uh","title":"GE FANUC UR6UH Digital I\/O Module UR 6UH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE UR-6UH is a Digital I\/O Module designed for use with the UR Series of Multilin Universal Relay Systems. It is engineered to control and monitor a wide range of auxiliary equipment, making it a versatile and cost-effective solution for various industrial applications.\u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 6 inches L x 7 inches W x 1.5 inches H\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353055076664,"sku":"UR 6UH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/7c14a6f4693857c2d645f4dcd4e8941d.jpg?v=1729245886"},{"product_id":"ge-fanuc-ur8ah-ct-vt-module-ur-8ah","title":"GE FANUC UR8AH CT\/VT Module UR 8AH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE UR-8AH is a CT\/VT Module designed for use in the UR Series of Multilin Universal Relay Systems. It provides the relay with three 1A\/5A Phase CTs, one 1A\/5A Ground CT, and four Voltage Transformers (VTs), enhancing the relay's measurement capabilities.\u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 15 cm L x 18 cm W x 4 cm H\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs, 9 oz (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353057501496,"sku":"UR 8AH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/d32702f5e3d131be6b8b6d5385c7b4e6.jpg?v=1729246013"},{"product_id":"ge-fanuc-ur6ch-digital-i-o-module-ur-6ch","title":"GE FANUC UR6CH Digital I\/O Module UR 6CH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE UR-6CH is a Digital I\/O Module designed for use with the UR Series of Multilin Universal Relay Systems. It enables communication between UR relays and auxiliary equipment by providing digital inputs and outputs, making it suitable for industrial applications that require high-speed data acquisition and control capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Approx. 6 inches (L) x 7 inches (W) x 1.5 inches (H)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353060876600,"sku":"UR 6CH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/9a43871a4e67fb01909ead5cde34849d.jpg?v=1729246109"},{"product_id":"ge-fanuc-ur6th-digital-i-o-module-ur-6th","title":"GE FANUC UR6TH Digital I\/O Module UR 6TH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe \u003cstrong\u003eGE UR-6TH\u003c\/strong\u003e is a Digital I\/O Module specifically designed for the UR Series of Multilin Universal Relay Systems. This module enables UR relays to effectively communicate with auxiliary equipment, making it ideal for industrial applications that demand high-speed data acquisition and control capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLength: Approx. 6 inches\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eWidth: Approx. 7 inches\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eHeight: Approx. 1.5 inches\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.15 kg\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353065988408,"sku":"UR 6TH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/f4fbefb860645b09f256aa2a700d0562.jpg?v=1729246269"},{"product_id":"ge-fanuc-ur8fh-universal-relay-module-ur-8fh","title":"GE FANUC UR8FH Universal Relay Module UR 8FH","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe GE UR-8FH is a CT\/VT Module designed for use in the UR Series of Multilin Universal Relay Systems. It provides the relay with three 1A\/5A phase current transformers, one 1A\/5A ground current transformer, and four voltage transformer terminals, enhancing the relay's measurement capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approximately 15 cm (L) x 18 cm (W) x 4 cm (H)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs, 9 oz (approximate)\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Multilin\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49353070641464,"sku":"UR 8FH","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/04c6ca4a4df0dbda59bad434e8a81ec9.jpg?v=1729246405"},{"product_id":"ge-fanuc-ic200acc201-expansion-terminator-plug","title":"GE FANUC | IC200ACC201 | Expansion Terminator Plug","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ACC201\u003c\/strong\u003e is an Expansion Terminator Plug designed for use with GE FANUC VersaMax PLCs or I\/O stations. It ensures proper termination of unused communication channels, maintaining system integrity and performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: IC200ACC201\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubcategory\u003c\/strong\u003e: Connector\/Terminal\/Pin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.86 lbs (0.84 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: GE FANUC VersaMax PLCs, I\/O stations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Terminates unused communication channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: High-grade industrial plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL, CE, CSA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 15 g for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration\u003c\/strong\u003e: 5 g at 10-500 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -20°C to +70°C (-4°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5% to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49387950047544,"sku":"IC200ACC201","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ACC201.jpg?v=1730165897"},{"product_id":"ge-fanuc-ur-6dh-ur-6dh-ur6dh-digital-i-o-module","title":"GE FANUC | UR-6DH | UR 6DH | UR6DH | Digital I\/O Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-6DH\u003c\/strong\u003e is a Digital I\/O Module from GE Multilin that provides the relay with digital contacts, enabling communication with equipment in the power system. With sixteen contact inputs, it can replace current modules or add new capabilities without the need for costly hardwiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric Multilin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: approx. 2.5 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: approx. 6 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 7 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 1.5 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module interfaces better with GE Multilin's EnerVista UR software, enhancing usability over traditional methods.\u003c\/li\u003e\n\u003cli\u003eFeatures tools like Viewpoint Monitoring and Viewpoint Maintenance for easy settings adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact Types\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContains only Form-C contacts; ensure compatibility with your system's needs.\u003c\/li\u003e\n\u003cli\u003eOther modules in the series offer combinations of Form-A and Form-C contacts for greater flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388019745080,"sku":"UR6DH","price":260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6DH.jpg?v=1730165896"},{"product_id":"ge-fanuc-ur-9eh-ur-9eh-ur9eh-cpu-module","title":"GE FANUC | UR-9EH | UR 9EH | UR9EH | CPU Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-9EH\u003c\/strong\u003e is a CPU module from GE Multilin designed to replace a defunct module or upgrade an existing one in the Universal Relays series. It provides essential computing power through logic algorithms, gates, latches, and timers, and does not require a surge ground connection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric Multilin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNew CPU modules must be used with new CT\/VT modules.\u003c\/li\u003e\n\u003cli\u003eOld CPU modules must be used with old CT\/VT modules to avoid HARDWARE MISMATCH or DSP ERROR displays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Settings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan be modified using the keypad and faceplate or EnerVista UR.\u003c\/li\u003e\n\u003cli\u003eFeatures like SERVER SCANNING can be disabled to free up CPU resources, beneficial for users not needing IEC 61850 client\/server functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlug \u0026amp; Play Capabilities\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically establishes basic CPU settings, easing the programming burden and allowing users to focus on optimizing their system settings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388024332600,"sku":"UR9EH","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR9EH.jpg?v=1730165897"},{"product_id":"ge-fanuc-ur-1hh-ur-1hh-ur1hh-power-supply-module","title":"GE FANUC | UR-1HH | UR 1HH | UR1HH | Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-1HH\u003c\/strong\u003e is a power supply module from GE Multilin designed for use in the Universal Relays series. This high-power unit operates with a power rating of 125-250 VDC and 100-240 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric Multilin (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: approx. 1.15 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: approx. 15 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 18 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 4 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower Ratings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC\u003c\/strong\u003e: 125-250 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC\u003c\/strong\u003e: 100-240 V at 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModule Replacement\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures a hinged faceplate for easy access to module installations.\u003c\/li\u003e\n\u003cli\u003eUsers can replace faulty modules by disconnecting connections, removing clips, and inserting new modules into the correct position.\u003c\/li\u003e\n\u003cli\u003eModules must be replaced with like models, so it’s important to note the original slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Considerations\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplacement should only be done with control power removed to avoid damage or injury.\u003c\/li\u003e\n\u003cli\u003eUsers should utilize electrostatic discharge protection, such as a static strap, when handling modules while the relay is energized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe power rating of the UR-1HH allows for flexibility in power supply options, as Universal Relays can accept modules from both high and low voltage ranges.\u003c\/li\u003e\n\u003cli\u003eOriginally, the input voltage range for earlier generations was 88 to 300 VDC, while the newer SH modules have a range of 88 to 400 VDC.\u003c\/li\u003e\n\u003cli\u003eIt is advisable to use power supply modules from the same generation within a single Universal Relay for optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388143247672,"sku":"UR1HH","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR1HH.jpg?v=1730165899"},{"product_id":"ge-fanuc-ur-8nh-ur-8nh-ur8nh-ct-vt-module","title":"GE FANUC | UR-8NH | UR 8NH | UR8NH | CT\/VT Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-8NH\u003c\/strong\u003e is a CT\/VT Module from GE Multilin, equipped with advanced diagnostic capabilities to enhance the functionality of the Universal Relays series. It provides the relay with standard 8CT, enabling effective monitoring and management of power systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: UR-8NH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.15 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: approx. 6 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 7 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 1.5 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplaces broken modules, upgrades older modules, or adds new capabilities to systems lacking a CT\/VT module.\u003c\/li\u003e\n\u003cli\u003eSupports up to twenty-four analog current transformer and voltage transformer signals, compatible with both 1 A and 5 A ratings.\u003c\/li\u003e\n\u003cli\u003eOther CT\/VT modules may offer features like high-impedance fault detection and ground fault protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates with the Universal Relay series’ standardized health diagnostics to assess hardware health at startup and during operation.\u003c\/li\u003e\n\u003cli\u003eAdvanced Health Diagnostics can monitor for potentially harmful system conditions, presenting information through the LCD or EnerVista UR.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEarly detection of issues is crucial for preserving system health, making the relay’s monitoring of CT\/VT input circuitry and components a valuable feature for users.\u003c\/li\u003e\n\u003cli\u003eThe scalable design allows for streamlined installation and provides ample information to support users throughout the process.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388468732216,"sku":"UR8NH","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8NH.jpg?v=1730165894"},{"product_id":"ge-fanuc-ur-8lh-ur-8lh-ur8lh-ct-vt-module","title":"GE FANUC | UR-8LH | UR 8LH | UR8LH | CT\/VT Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eUR-8LH\u003c\/strong\u003e is a CT\/VT module from GE Multilin designed for the Universal Relay series, supplying the relay with 4CT\/4VT capabilities along with enhanced diagnostic features.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: UR-8LH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: General Electric Multilin (GE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: approx. 2 lb 9 oz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: approx. 6 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 7 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to replace existing modules, upgrade current systems, or provide new capabilities to Universal Relays that lack this module.\u003c\/li\u003e\n\u003cli\u003eEquipped with enhanced diagnostics to verify the integrity of analog signals, ensuring reliable operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCT\/VT Functionality\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScales down current and voltage values to levels manageable by the relay, enabling it to calculate and output relevant current and voltage ratios.\u003c\/li\u003e\n\u003cli\u003eCritical for identifying hazardous conditions in the system and facilitating appropriate responses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module employs an advanced algorithm to assess signal integrity.\u003c\/li\u003e\n\u003cli\u003eData can be accessed through the front faceplate’s LCD or via a computer using the EnerVista UR software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility and Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe UR-8LH must be paired with a new CPU to avoid hardware mismatch errors, as it is a newer module.\u003c\/li\u003e\n\u003cli\u003eCompatible with firmware versions of at least 4.0x; older CPUs and CT\/VT modules require firmware versions of 3.4x or earlier.\u003c\/li\u003e\n\u003cli\u003eSupports up to 24 signals for AC power line monitoring.\u003c\/li\u003e\n\u003cli\u003eSensitive ground input for ground fault protection is available in certain models (e.g., 8G, 8J, 8M, and 8R).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388496224568,"sku":"UR8LH","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8LH.jpg?v=1730165896"},{"product_id":"ge-fanuc-t35-transformer-protection-system-multilin","title":"GE FANUC | T35 | Transformer Protection System Multilin","description":"\u003ch3\u003eTransformer Protection System\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eT35\u003c\/strong\u003e is designed to provide basic transformer protection functions for a variety of transformer applications. It uses multiple current inputs to provide primary protection and backup protection of transformers, including differential, phase, and ground overcurrent. The relay can be configured to accept up to 6 sets of current inputs to provide proper differential restraint for applications with three-winding transformers with windings configured in dual-breaker arrangements.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure high-speed transformer differential protection in a cost-effective package\u003c\/li\u003e\n\u003cli\u003eImproved security for transformer energization and inrush\u003c\/li\u003e\n\u003cli\u003eApplication flexibility for transformers with up to 6 sets of CTs\u003c\/li\u003e\n\u003cli\u003eRobust network security enabling Critical Infrastructure Protection\u003c\/li\u003e\n\u003cli\u003eAdvanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE, IEC 61869 or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization, and reduced cost of ownership\u003c\/li\u003e\n\u003cli\u003eRoutable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications\u003c\/li\u003e\n\u003cli\u003eAdvanced Cybersecurity features “CyberSentryTM” that help meet modern industry requirements\u003c\/li\u003e\n\u003cli\u003eApplication flexibility with multiple I\/O options including high-density I\/O, programmable logic, modularity, and specific customization\u003c\/li\u003e\n\u003cli\u003eAn integrated large, full-color display provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombined protection for transformer and small bus zone, including breaker-and-a-half and ring bus configurations\u003c\/li\u003e\n\u003cli\u003eStand-alone or component in automated substation control systems\u003c\/li\u003e\n\u003cli\u003eApplicable for transformers with windings in a ring bus or breaker-and-a-half configuration\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49388504645944,"sku":"T35","price":287.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/T35_dd85c342-7b51-4489-9576-bd0c38a0bc93.jpg?v=1730169578"},{"product_id":"ge-fanuc-m60-multilin-motor-relay","title":"GE FANUC M60 Multilin Motor Relay","description":"\u003ch3\u003eDCMA Inputs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input (mA DC):\u003c\/strong\u003e 0 to –1, 0 to +1, –1 to +1, 0 to 5, 0 to 10, 0 to 20, 4 to 20 (programmable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 379 Ω ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Range:\u003c\/strong\u003e –1 to +20 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.2% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Passive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRTD Inputs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypes (3-wire):\u003c\/strong\u003e 100 Ω Platinum, 100 \u0026amp; 120 Ω Nickel, 10 Ω Copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Current:\u003c\/strong\u003e 5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e –50 to +250°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 36 V pk-pk\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49400786616632,"sku":"M60","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/M60.jpg?v=1730363627"},{"product_id":"ge-fanuc-f650babf1g0hi-f650-digital-bay-controller","title":"GE FANUC F650BABF1G0HI | F650 Digital Bay Controller","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe GE FANUC\u003cstrong\u003e F650BABF1G0HI\u003c\/strong\u003e is an F650 Digital Bay Controller designed for reliable and efficient operation in various industrial environments. This controller integrates advanced communication protocols and a range of features to enhance performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number\u003c\/strong\u003e: F650BABF1G0HI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: F650 Digital Bay Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type\u003c\/strong\u003e: Basic Display (B)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Serial Communications Board\u003c\/strong\u003e: Redundant RS485 (A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Ethernet Communications Board\u003c\/strong\u003e: 10\/100 Base TX (B)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Board in Slot F\u003c\/strong\u003e: 16 Digital Inputs + 8 Outputs (1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Board in Slot G\u003c\/strong\u003e: None (0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e110-250 Vdc (range 88 – 300)\u003c\/li\u003e\n\u003cli\u003e120-230 Vac (range 96 – 250)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguage\u003c\/strong\u003e: English (-)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eModbus® RTU\u003c\/li\u003e\n\u003cli\u003eTCP\/IP\u003c\/li\u003e\n\u003cli\u003eDNP 3.0 Level 2\u003c\/li\u003e\n\u003cli\u003eIEC 60870-5-104\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Without Harsh (Chemical) Environment Conformal Coating (-)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Display\u003c\/strong\u003e: Display with RS232 (-)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 5 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49418379788600,"sku":"F650BABF1G0HI","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F650BABF1G0HI.jpg?v=1730799861"},{"product_id":"ge-fanuc-multilin-t60-transformer-protection-system","title":"GE FANUC Multilin  T60 | Transformer Protection System","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe GE FANUC Multilin\u003cstrong\u003e T60\u003c\/strong\u003e is a Transformer Protection System designed for various power applications, including autotransformers, generator step-up transformers, split-phase, angle-regulating transformers, and reactors. It utilizes multiple current and voltage inputs to provide primary and backup protection for transformers. Key protection features include differential, ground differential, five distance zones, phase, neutral, ground overcurrent, under and overvoltage, under and overfrequency, over-fluxing, and breaker failure protections.\u003c\/p\u003e\n\u003ch3\u003eProtection \u0026amp; Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eDual-slope, dual-breakpoint differential restraint characteristic\u003c\/li\u003e\n\u003cli\u003eRestricted and unrestrained differential\u003c\/li\u003e\n\u003cli\u003eInter-turn fault detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e2nd harmonic inrush detection\u003c\/li\u003e\n\u003cli\u003eOverexcitation inhibit with independent harmonic detection element\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTransformer Overexcitation Protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Fault Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eRestricted ground fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoss-of-Life Monitoring\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAging factor and hottest spot detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup Distance Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eFive zones with power swing detection and load encroachment function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eSynchrocheck, Rate of Change of Frequency (ROCOF), over and under frequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMonitoring \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetering\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCurrent, voltage, power, energy, frequency, temperature, transformer monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynchrophasors\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eP \u0026amp; M class synchrophasors of voltage, current, and sequence components (1 to 120 frames\/sec)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOscillography\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAnalog and digital parameters at 64 samples\/cycle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Recorder\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1024 time-tagged events with a 0.5 ms scan of digital inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logger\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e16 channels with a sampling rate of up to 1 sample\/cycle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity Audit Trails\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eSettings for tracking changes to T60 configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eThree independent 100 Mbps Ethernet ports for dedicated LAN support, eliminating latency effects of heavy traffic protocols on critical communications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-Synch Protocol\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eEmbedded IEEE 1588 time-synch protocol support, eliminating the need for dedicated IRIG-B wiring for IEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Data Exchange\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eDirect I\/O secures high-speed binary data exchange between URs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Availability\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eReduced failover time to zero through IEC 62439-3 Parallel Redundancy Protocol (PRP), High Availability Seamless Redundancy (HSR), or dual HSR support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49418392699192,"sku":"T60","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/T60.jpg?v=1730799865"},{"product_id":"350-c-p5-g5-h-s-m-n-p-sn-d-n-ge-fanuc-feeder-protection-relay","title":"350-C-P5-G5-H-S-M-N-P-SN-D-N | GE Fanuc | Feeder Protection Relay","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cstrong\u003e 350-C-P5-G5-H-S-M-N-P-SN-D-N\u003c\/strong\u003e is a high-performance Feeder Protection Relay, suitable for low, medium, and high-voltage applications. It integrates advanced protection, control, and monitoring features such as arc flash protection, metering, diagnostics, and communication capabilities, ensuring reliable feeder operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125-250 VDC\u003c\/strong\u003e or \u003cstrong\u003e100-240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Case Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl\u003c\/strong\u003e: CLP, Lockout (8 total outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Design\u003c\/strong\u003e: Drawout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCurrent Inputs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5A\u003c\/strong\u003e (3-phase)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Input\u003c\/strong\u003e: 5A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e: Detects and trips on overcurrent conditions to prevent damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Fault Protection\u003c\/strong\u003e: Detects and trips on ground faults, enhancing safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Fault Protection\u003c\/strong\u003e: Isolates faulted sections of the feeder to minimize damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReclosing\u003c\/strong\u003e: Automatically attempts to restore power after a fault clears.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: 350-C-P5-G5-H-S-M-N-P-SN-D-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: 350 Feeder Protection System\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49510159876408,"sku":"350-C-P5-G5-H-S-M-N-P-SN-D-N","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/350-C-P5-G5-H-S-M-N-P-SN-D-N.jpg?v=1733735200"},{"product_id":"pqmii-c-ge-fanuc-power-quality-meter","title":"PQMII-C | GE Fanuc | Power Quality Meter","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cstrong\u003e PQMII-C\u003c\/strong\u003e Power Quality Meter is designed for continuous monitoring of three-phase power systems. It provides comprehensive power quality analysis, including measurements of current, voltage, real and reactive power, energy usage, power factor, and frequency. This meter is ideal for use in medium and low voltage systems such as distribution feeders, transformers, generators, capacitor banks, and motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower and Frequency\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power\u003c\/strong\u003e: 90-300 VDC \/ 70-265 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 20 VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDisplay and Indication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: Digital\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndication\u003c\/strong\u003e: LED\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTermination and Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination\u003c\/strong\u003e: Screw Terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Panel Mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: PQMII-C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Electrical Products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubcategory\u003c\/strong\u003e: Power Meter Panel\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49510167249208,"sku":"PQMII-C","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PQMII-C.jpg?v=1733735204"},{"product_id":"multilin-369-hi-0-0-0-0-0-e-ge-fanuc-motor-management-relay","title":"Multilin 369-HI-0-0-0-0-0-E | GE Fanuc | Motor Management Relay","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cstrong\u003e \u003c\/strong\u003eGE Fanuc \u003cstrong\u003e369-HI-0-0-0-0-0-E\u003c\/strong\u003e Motor Management Relay is designed for efficient motor protection and control. It provides advanced diagnostics, protection, and monitoring capabilities for motor management applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: 369-HI-0-0-0-0-0-E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: 369 Motor Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Type\u003c\/strong\u003e: Standard Faceplate (No Enhanced Diagnostics)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Accuracy\u003c\/strong\u003e: ± 1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Loss\u003c\/strong\u003e: 2 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Primary\u003c\/strong\u003e: 1 to 5000A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Record Capacity\u003c\/strong\u003e: Last 512 events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFailsafe Trip Holdup\u003c\/strong\u003e: 100 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Input Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDust\/Moisture Rating\u003c\/strong\u003e: IP50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Current Input Conversion\u003c\/strong\u003e: True RMS, 1.04ms\/sample\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal HI Voltage Range\u003c\/strong\u003e: 100 to 240 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConnectivity and Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Back Ports\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS485 Baud Rate\u003c\/strong\u003e: 1200 to 19200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of Back Port\u003c\/strong\u003e: RS485\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Sensing Current\u003c\/strong\u003e: 3 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplice Loss\u003c\/strong\u003e: One splice every 2 km @ 0.05 dB loss\/splice\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49510181077304,"sku":"369-HI-0-0-0-0-0-E","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/369-HI-0-0-0-0-0-E.jpg?v=1733735201"},{"product_id":"pqmii-c-a-ge-fanuc-power-quality-meter","title":"PQMII-C-A | GE Fanuc Power Quality Meter","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc\u003cstrong\u003e PQMII-C-A \u003c\/strong\u003ePower Quality Meter is designed to provide continuous, real-time monitoring and analysis of three-phase power systems. It offers comprehensive energy management and power quality analysis, ideal for medium and low voltage systems such as distribution feeders, transformers, generators, capacitor banks, and motors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: PQMII-C-A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 20 VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMonitoring and Metering Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement\u003c\/strong\u003e: Phase A\/B\/C\/N current (A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Measurement\u003c\/strong\u003e: Real power (kW), Reactive power (kvar), Apparent power (kVA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Measurement\u003c\/strong\u003e: Energy use (Wh, kWh)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor\u003c\/strong\u003e: True power factor (PF), Crest factor (K factor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: Frequency (Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnbalance\u003c\/strong\u003e: Current and voltage unbalance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRecording and Analysis Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Recorder\u003c\/strong\u003e: Records up to 150 events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaveform Capture\u003c\/strong\u003e: Captures power quality disturbances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Disturbance Recorder (VDR)\u003c\/strong\u003e: Monitors voltage dips (sags) and spikes (swells) with capacity for 500 events\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49510184812856,"sku":"PQMII-C-A","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PQMII-C-A.jpg?v=1733735204"},{"product_id":"ge-fanuc-469-p5-hi-a20-t-motor-management-relay","title":"GE FANUC 469-P5-HI-A20-T Motor Management Relay","description":"\u003ch3\u003e\u003cstrong\u003e469 Motor Management Relay Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e469 Motor Management Relay\u003c\/strong\u003e is a microprocessor-based relay designed to offer protection and management for medium to large horsepower motors and their driven equipment. It integrates various functions such as motor protection, fault diagnostics, power metering, and RTU (Remote Terminal Unit) functionalities in one cost-effective drawout package. The relay comes equipped with six output relays that can be used for trips, alarms, and start blocks, providing comprehensive protection and control.\u003c\/p\u003e\n\n\u003cp\u003eThe functionality of the 469 Relay is illustrated using ANSI device numbers as shown in the single-line diagram below.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ch4\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOptions\u003c\/strong\u003e: Low (LO) \/ High (HI) – must be specified when ordering\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRange\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\u003cstrong\u003eLO\u003c\/strong\u003e:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eDC: 20 to 60 V DC\u003c\/li\u003e\n\t\t\t\u003cli\u003eAC: 20 to 48 V AC at 48 to 62 Hz\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cstrong\u003eHI\u003c\/strong\u003e:\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003eDC: 90 to 300 V DC\u003c\/li\u003e\n\t\t\t\u003cli\u003eAC: 70 to 265 V AC at 48 to 62 Hz\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 45 VA (max), 25 VA (typical)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOperation Time Without Supply Voltage\u003c\/strong\u003e: 30 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003ePhase Current Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Secondary\u003c\/strong\u003e: 1 A or 5 A (to be specified with order)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBurden\u003c\/strong\u003e: Less than 0.2 VA at rated load\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eConversion Range\u003c\/strong\u003e: 0.05 to 20 × CT\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u0026lt; 2 × CT: ± 0.5% of 2 × CT\u003c\/li\u003e\n\t\t\u003cli\u003e≥ 2 × CT: ± 1% of 20 × CT\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Withstand\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e1 second @ 80 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003e2 seconds @ 40 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003eContinuous @ 3 × rated current\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eGround Current Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Secondary\u003c\/strong\u003e: 1 A or 5 A (setpoint)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBurden\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u0026lt; 0.2 VA at rated load (for 1 A or 5 A)\u003c\/li\u003e\n\t\t\u003cli\u003e\u0026lt; 0.25 VA for 50:0.025 @ 25 A\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eConversion Range\u003c\/strong\u003e: 0.02 to 1 × CT Primary Amps\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e± 0.5% of 1 × CT for 5 A\u003c\/li\u003e\n\t\t\u003cli\u003e± 0.5% of 5 × CT for 1 A\u003c\/li\u003e\n\t\t\u003cli\u003e± 0.125 A for 50:0.025\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Withstand\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e1 second @ 80 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003e2 seconds @ 40 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003eContinuous @ 3 × rated current\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eDifferential Phase Current Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Primary\u003c\/strong\u003e: 1 to 5000 A\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Secondary\u003c\/strong\u003e: 1 A or 5 A (setpoint)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBurden\u003c\/strong\u003e: Less than 0.2 VA at rated load\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eConversion Range\u003c\/strong\u003e: 0.02 to 1 × CT\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e± 0.5% of 1 × CT for 5 A\u003c\/li\u003e\n\t\t\u003cli\u003e± 0.5% of 5 × CT for 1 A\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCT Withstand\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e1 second @ 80 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003e2 seconds @ 40 × rated current\u003c\/li\u003e\n\t\t\u003cli\u003eContinuous @ 3 × rated current\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eVoltage Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eVT Ratio\u003c\/strong\u003e: 1.00 to 150.00:1 (in steps of 0.01)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eVT Secondary\u003c\/strong\u003e: 273 V AC (full scale)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eConversion Range\u003c\/strong\u003e: 0.05 to 1.00 × full scale\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ± 0.5% of full scale\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMax. Continuous Voltage\u003c\/strong\u003e: 280 V AC\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBurden\u003c\/strong\u003e: \u0026gt; 500 kΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eInputs\u003c\/strong\u003e: 9 opto-isolated inputs\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eExternal Switch\u003c\/strong\u003e: Dry contact \u0026lt; 800 Ω, or open collector NPN transistor from sensor\n\t\u003cul\u003e\n\t\t\u003cli\u003e6 mA sinking from internal 4 kΩ pull-up at 24 V DC with Vce \u0026lt; 4 V DC\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSensor Supply\u003c\/strong\u003e: +24 V DC at 20 mA max.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eRTD Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eTypes Supported\u003c\/strong\u003e:\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e100 Ω Platinum (DIN.43760)\u003c\/li\u003e\n\t\t\u003cli\u003e100 Ω Nickel\u003c\/li\u003e\n\t\t\u003cli\u003e120 Ω Nickel\u003c\/li\u003e\n\t\t\u003cli\u003e10 Ω Copper\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRTD Sensing Current\u003c\/strong\u003e: 5 mA\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: 36 Vpk (isolated with analog inputs and outputs)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRange\u003c\/strong\u003e: -50 to +250°C\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±2°C\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eLead Resistance\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003e25 Ω max per lead for Pt and Ni types\u003c\/li\u003e\n\t\t\u003cli\u003e3 Ω max per lead for Cu type\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eNo Sensor Detection\u003c\/strong\u003e: \u0026gt; 1000 Ω\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eShort\/Low Alarm\u003c\/strong\u003e: \u0026lt; –50°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eTrip Coil Supervision\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eApplicable Voltage\u003c\/strong\u003e: 20 to 300 V DC \/ V AC\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eTrickle Current\u003c\/strong\u003e: 2 to 5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eAnalog Current Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eInput Types\u003c\/strong\u003e: 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA (setpoint)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 226 Ω ±10%\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eConversion Range\u003c\/strong\u003e: 0 to 21 mA\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% of full scale\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eAnalog Input Supply\u003c\/strong\u003e: +24 V DC at 100 mA max.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: ≤ 100 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRS232 Port\u003c\/strong\u003e: 1, front panel, non-isolated\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRS485 Ports\u003c\/strong\u003e: 2, isolated together @ 36 Vpk\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBaud Rates\u003c\/strong\u003e:\n\t\u003cul\u003e\n\t\t\u003cli\u003eRS485: 300, 1200, 2400, 4800, 9600, 19200\u003c\/li\u003e\n\t\t\u003cli\u003eRS232: 9600\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eParity\u003c\/strong\u003e: None, Odd, Even\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eProtocol\u003c\/strong\u003e: Modbus® RTU \/ half duplex\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49643773952312,"sku":"469-P5-HI-A20-T","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/686dfa2e63bb0eb091cea001f149c16e.jpg?v=1737698133"},{"product_id":"ur-67h-ur-67h-ur67h-ge-multilin-digital-i-o-module","title":"UR-67H | UR 67H | UR67H GE Multilin Digital I\/O Module","description":"\u003ch3 data-start=\"0\" data-end=\"17\"\u003eDescription\u003c\/h3\u003e\n\u003cul data-start=\"18\" data-end=\"192\"\u003e\n\u003cli data-start=\"18\" data-end=\"43\"\u003e\n\u003cstrong data-start=\"20\" data-end=\"29\"\u003eModel\u003c\/strong\u003e: \u003cstrong data-start=\"31\" data-end=\"41\"\u003eUR-67H\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"44\" data-end=\"84\"\u003e\n\u003cstrong data-start=\"46\" data-end=\"62\"\u003eProduct Type\u003c\/strong\u003e: Digital I\/O Module\u003c\/li\u003e\n\u003cli data-start=\"85\" data-end=\"111\"\u003e\n\u003cstrong data-start=\"87\" data-end=\"96\"\u003eBrand\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003cli data-start=\"112\" data-end=\"153\"\u003e\n\u003cstrong data-start=\"114\" data-end=\"125\"\u003eOutputs\u003c\/strong\u003e: 8 Form-A Digital Outputs\u003c\/li\u003e\n\u003cli data-start=\"154\" data-end=\"192\"\u003e\n\u003cstrong data-start=\"156\" data-end=\"165\"\u003eUsage\u003c\/strong\u003e: Universal Relays Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"194\" data-end=\"212\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"213\" data-end=\"445\"\u003e\n\u003cli data-start=\"213\" data-end=\"256\"\u003e\n\u003cstrong data-start=\"215\" data-end=\"231\"\u003eI\/O Capacity\u003c\/strong\u003e: 96 inputs, 64 outputs\u003c\/li\u003e\n\u003cli data-start=\"257\" data-end=\"317\"\u003e\n\u003cstrong data-start=\"259\" data-end=\"276\"\u003eCommunication\u003c\/strong\u003e: Connects auxiliary equipment to relay\u003c\/li\u003e\n\u003cli data-start=\"318\" data-end=\"385\"\u003e\n\u003cstrong data-start=\"320\" data-end=\"337\"\u003eFunctionality\u003c\/strong\u003e: Processes signals for control and protection\u003c\/li\u003e\n\u003cli data-start=\"386\" data-end=\"445\"\u003e\n\u003cstrong data-start=\"388\" data-end=\"408\"\u003eModule Reference\u003c\/strong\u003e: Check manual for included modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"447\" data-end=\"475\"\u003eAdditional Information\u003c\/h3\u003e\n\u003cul data-start=\"476\" data-end=\"633\" data-is-last-node=\"\"\u003e\n\u003cli data-start=\"476\" data-end=\"519\"\u003e\n\u003cstrong data-start=\"478\" data-end=\"503\"\u003eMonitoring \u0026amp; Latching\u003c\/strong\u003e: Not included\u003c\/li\u003e\n\u003cli data-start=\"520\" data-end=\"574\"\u003e\n\u003cstrong data-start=\"522\" data-end=\"538\"\u003eInterlocking\u003c\/strong\u003e: Latching outputs in other models\u003c\/li\u003e\n\u003cli data-start=\"575\" data-end=\"633\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"577\" data-end=\"594\"\u003ePost-Purchase\u003c\/strong\u003e: Track modules for additional features\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49706383638840,"sku":"UR-67H","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR67H_2.jpg?v=1739352976"},{"product_id":"ge-multilin-ur-6ph-ur-6ph-digital-i-o-module-multilin-ur6ph","title":"GE Multilin UR-6PH | UR 6PH Digital I\/O Module Multilin UR6PH","description":"\u003ch3 data-start=\"0\" data-end=\"14\"\u003eOverview\u003c\/h3\u003e\n\u003cul data-start=\"15\" data-end=\"239\"\u003e\n\u003cli data-start=\"15\" data-end=\"40\"\u003e\n\u003cstrong data-start=\"17\" data-end=\"26\"\u003eModel\u003c\/strong\u003e: \u003cstrong data-start=\"28\" data-end=\"38\"\u003eUR-6PH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"41\" data-end=\"81\"\u003e\n\u003cstrong data-start=\"43\" data-end=\"59\"\u003eProduct Type\u003c\/strong\u003e: Digital I\/O Module\u003c\/li\u003e\n\u003cli data-start=\"82\" data-end=\"108\"\u003e\n\u003cstrong data-start=\"84\" data-end=\"93\"\u003eBrand\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003cli data-start=\"109\" data-end=\"150\"\u003e\n\u003cstrong data-start=\"111\" data-end=\"122\"\u003eOutputs\u003c\/strong\u003e: 6 Form-A Digital Outputs\u003c\/li\u003e\n\u003cli data-start=\"151\" data-end=\"183\"\u003e\n\u003cstrong data-start=\"153\" data-end=\"163\"\u003eInputs\u003c\/strong\u003e: 4 Digital Inputs\u003c\/li\u003e\n\u003cli data-start=\"184\" data-end=\"239\"\u003e\n\u003cstrong data-start=\"186\" data-end=\"198\"\u003eMetering\u003c\/strong\u003e: Optional voltage and current metering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"241\" data-end=\"255\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"256\" data-end=\"545\"\u003e\n\u003cli data-start=\"256\" data-end=\"286\"\u003e\n\u003cstrong data-start=\"258\" data-end=\"272\"\u003eMonitoring\u003c\/strong\u003e: Integrated\u003c\/li\u003e\n\u003cli data-start=\"287\" data-end=\"323\"\u003e\n\u003cstrong data-start=\"289\" data-end=\"303\"\u003eProtection\u003c\/strong\u003e: High-performance\u003c\/li\u003e\n\u003cli data-start=\"324\" data-end=\"366\"\u003e\n\u003cstrong data-start=\"326\" data-end=\"337\"\u003eDisplay\u003c\/strong\u003e: Full-color, large display\u003c\/li\u003e\n\u003cli data-start=\"367\" data-end=\"403\"\u003e\n\u003cstrong data-start=\"369\" data-end=\"383\"\u003eNetworking\u003c\/strong\u003e: 3 Ethernet Ports\u003c\/li\u003e\n\u003cli data-start=\"404\" data-end=\"456\"\u003e\n\u003cstrong data-start=\"406\" data-end=\"423\"\u003eConfiguration\u003c\/strong\u003e: Extensive programming options\u003c\/li\u003e\n\u003cli data-start=\"457\" data-end=\"521\"\u003e\n\u003cstrong data-start=\"459\" data-end=\"472\"\u003eRecording\u003c\/strong\u003e: Digital sequence of event and fault recording\u003c\/li\u003e\n\u003cli data-start=\"522\" data-end=\"545\"\u003e\n\u003cstrong data-start=\"524\" data-end=\"533\"\u003eGOOSE\u003c\/strong\u003e: Routable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"547\" data-end=\"570\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cul data-start=\"571\" data-end=\"673\" data-is-last-node=\"\"\u003e\n\u003cli data-start=\"571\" data-end=\"595\"\u003e\n\u003cstrong data-start=\"573\" data-end=\"583\"\u003eWeight\u003c\/strong\u003e: 3 pounds\u003c\/li\u003e\n\u003cli data-start=\"596\" data-end=\"624\"\u003e\n\u003cstrong data-start=\"598\" data-end=\"608\"\u003eStatus\u003c\/strong\u003e: Discontinued\u003c\/li\u003e\n\u003cli data-start=\"625\" data-end=\"673\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"627\" data-end=\"642\"\u003eApplication\u003c\/strong\u003e: Controls substation equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49706388259128,"sku":"UR-6PH","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6PH.jpg?v=1739352975"},{"product_id":"multilin-ge-469-p5-hi-a20-e-motor-management-relay","title":"Multilin GE 469-P5-HI-A20-E Motor Management Relay","description":"\u003ch3 data-start=\"0\" data-end=\"14\"\u003eOverview\u003c\/h3\u003e\n\u003cul data-start=\"15\" data-end=\"137\"\u003e\n\u003cli data-start=\"15\" data-end=\"49\"\u003e\n\u003cstrong data-start=\"17\" data-end=\"26\"\u003eModel\u003c\/strong\u003e: \u003cstrong data-start=\"28\" data-end=\"47\"\u003e469-P5-HI-A20-E\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"50\" data-end=\"92\"\u003e\n\u003cstrong data-start=\"52\" data-end=\"62\"\u003eSeries\u003c\/strong\u003e: 469 Motor Management Relay\u003c\/li\u003e\n\u003cli data-start=\"93\" data-end=\"137\"\u003e\n\u003cstrong data-start=\"95\" data-end=\"105\"\u003eOutput\u003c\/strong\u003e: Six Electromechanical Form C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"139\" data-end=\"163\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"164\" data-end=\"373\"\u003e\n\u003cli data-start=\"164\" data-end=\"223\"\u003e\n\u003cstrong data-start=\"166\" data-end=\"178\"\u003eAccuracy\u003c\/strong\u003e: ±1% of full scale (Analog Current Output)\u003c\/li\u003e\n\u003cli data-start=\"224\" data-end=\"286\"\u003e\n\u003cstrong data-start=\"226\" data-end=\"240\"\u003eBaud Rates\u003c\/strong\u003e: 300, 1200, 2400, 9600, 19200 (RS485 Ports)\u003c\/li\u003e\n\u003cli data-start=\"287\" data-end=\"338\"\u003e\n\u003cstrong data-start=\"289\" data-end=\"309\"\u003eVoltage AC Range\u003c\/strong\u003e: 70 to 265 VAC at 48-62 Hz\u003c\/li\u003e\n\u003cli data-start=\"339\" data-end=\"373\"\u003e\n\u003cstrong data-start=\"341\" data-end=\"360\"\u003eTrickle Current\u003c\/strong\u003e: 2 to 5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"434\" data-end=\"451\"\u003ePerformance\u003c\/h3\u003e\n\u003cul data-start=\"452\" data-end=\"575\"\u003e\n\u003cli data-start=\"452\" data-end=\"482\"\u003e\n\u003cstrong data-start=\"454\" data-end=\"473\"\u003eTiming Accuracy\u003c\/strong\u003e: ±0.5%\u003c\/li\u003e\n\u003cli data-start=\"483\" data-end=\"532\"\u003e\n\u003cstrong data-start=\"485\" data-end=\"499\"\u003eTime Delay\u003c\/strong\u003e: 1 to 30 seconds in steps of 1\u003c\/li\u003e\n\u003cli data-start=\"533\" data-end=\"575\"\u003e\n\u003cstrong data-start=\"535\" data-end=\"567\"\u003ePhase Short Circuit Elements\u003c\/strong\u003e: Trip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"577\" data-end=\"602\"\u003eAdditional Features\u003c\/h3\u003e\n\u003cul data-start=\"603\" data-end=\"770\" data-is-last-node=\"\"\u003e\n\u003cli data-start=\"603\" data-end=\"670\"\u003e\n\u003cstrong data-start=\"605\" data-end=\"631\"\u003eConfigurable Load Shed\u003c\/strong\u003e: Assignable to Digital Inputs 1 to 4\u003c\/li\u003e\n\u003cli data-start=\"671\" data-end=\"720\"\u003e\n\u003cstrong data-start=\"673\" data-end=\"695\"\u003eSecondary CT Input\u003c\/strong\u003e: 1 A or 5 A (setpoint)\u003c\/li\u003e\n\u003cli data-start=\"721\" data-end=\"745\"\u003e\n\u003cstrong data-start=\"723\" data-end=\"735\"\u003eIP Class\u003c\/strong\u003e: IP20-X\u003c\/li\u003e\n\u003cli data-start=\"746\" data-end=\"770\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"748\" data-end=\"764\"\u003eVoltage Type\u003c\/strong\u003e: High\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49706392715576,"sku":"469-P5-HI-A20-E","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/469-P5-HI-A20-E_2.jpg?v=1739352976"},{"product_id":"489-p5-lo-a20-e-ge-multilin-generator-management-relay","title":"489-P5-LO-A20-E | GE Multilin | Generator Management Relay","description":"\u003ch3 data-start=\"0\" data-end=\"22\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cul data-start=\"23\" data-end=\"159\"\u003e\n\u003cli data-start=\"23\" data-end=\"57\"\u003e\n\u003cstrong data-start=\"25\" data-end=\"34\"\u003eModel\u003c\/strong\u003e: \u003cstrong data-start=\"36\" data-end=\"55\"\u003e489-P5-LO-A20-E\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"58\" data-end=\"105\"\u003e\n\u003cstrong data-start=\"60\" data-end=\"70\"\u003eSeries\u003c\/strong\u003e: 489 Generator Management Relays\u003c\/li\u003e\n\u003cli data-start=\"106\" data-end=\"159\"\u003e\n\u003cstrong data-start=\"108\" data-end=\"124\"\u003eManufacturer\u003c\/strong\u003e: GE Multilin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"161\" data-end=\"185\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cul data-start=\"186\" data-end=\"323\"\u003e\n\u003cli data-start=\"186\" data-end=\"223\"\u003e\n\u003cstrong data-start=\"188\" data-end=\"198\"\u003eOutput\u003c\/strong\u003e: 4-20 mA Analog Output\u003c\/li\u003e\n\u003cli data-start=\"224\" data-end=\"254\"\u003e\n\u003cstrong data-start=\"226\" data-end=\"236\"\u003eWeight\u003c\/strong\u003e: Approx. 10 lbs\u003c\/li\u003e\n\u003cli data-start=\"255\" data-end=\"323\"\u003e\n\u003cstrong data-start=\"257\" data-end=\"284\"\u003eTachometer Configurable\u003c\/strong\u003e: Assignable to Digital Inputs 4 to 7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"325\" data-end=\"351\"\u003ePerformance Features\u003c\/h3\u003e\n\u003cul data-start=\"352\" data-end=\"557\"\u003e\n\u003cli data-start=\"352\" data-end=\"420\"\u003e\n\u003cstrong data-start=\"354\" data-end=\"386\"\u003eLow Forward Power Time Delay\u003c\/strong\u003e: 0.2 to 120.0 s in steps of 0.1\u003c\/li\u003e\n\u003cli data-start=\"421\" data-end=\"483\"\u003e\n\u003cstrong data-start=\"423\" data-end=\"451\"\u003ePulse Output Pulse Width\u003c\/strong\u003e: 200 to 1000 ms in steps of 1\u003c\/li\u003e\n\u003cli data-start=\"484\" data-end=\"557\"\u003e\n\u003cstrong data-start=\"486\" data-end=\"516\"\u003eIRIG-B Amplitude Modulated\u003c\/strong\u003e: 2.5 to 6.0 Vpk-pk at 3:1 signal ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"559\" data-end=\"578\"\u003eCommunication\u003c\/h3\u003e\n\u003cul data-start=\"579\" data-end=\"630\"\u003e\n\u003cli data-start=\"579\" data-end=\"630\"\u003e\n\u003cstrong data-start=\"581\" data-end=\"611\"\u003eCommunication Ports Parity\u003c\/strong\u003e: None, Odd, Even\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"632\" data-end=\"657\"\u003eProtection Features\u003c\/h3\u003e\n\u003cul data-start=\"658\" data-end=\"786\"\u003e\n\u003cli data-start=\"658\" data-end=\"707\"\u003e\n\u003cstrong data-start=\"660\" data-end=\"699\"\u003eHigh-Set Phase Overcurrent Elements\u003c\/strong\u003e: Trip\u003c\/li\u003e\n\u003cli data-start=\"708\" data-end=\"786\"\u003e\n\u003cstrong data-start=\"710\" data-end=\"749\"\u003ePhase Overcurrent Voltage Restraint\u003c\/strong\u003e: Programmable Fixed Characteristic\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49706395631928,"sku":"489-P5-LO-A20-E","price":305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/489-P5-LO-A20-E_2_63f32274-1406-421d-8b2d-2d260c29c248.jpg?v=1739352976"},{"product_id":"ge-multilin-g60-generator-protection-systems","title":"GE Multilin G60 Generator Protection Systems","description":"\u003ch3 data-start=\"0\" data-end=\"17\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"177\"\u003eThe \u003cstrong data-start=\"22\" data-end=\"41\"\u003eGE Multilin G60\u003c\/strong\u003e Generator Protection System provides protection for medium and large generators, including steam, combustion turbines, and hydro units.\u003c\/p\u003e\n\u003ch3 data-start=\"179\" data-end=\"197\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"198\" data-end=\"583\"\u003e\n\u003cli data-start=\"198\" data-end=\"255\"\u003e\n\u003cstrong data-start=\"200\" data-end=\"224\"\u003eGenerator Protection\u003c\/strong\u003e: Compliant with IEEE C37.102\u003c\/li\u003e\n\u003cli data-start=\"256\" data-end=\"302\"\u003e\n\u003cstrong data-start=\"258\" data-end=\"275\"\u003eCybersecurity\u003c\/strong\u003e: “CyberSentry™” features\u003c\/li\u003e\n\u003cli data-start=\"303\" data-end=\"363\"\u003e\n\u003cstrong data-start=\"305\" data-end=\"326\"\u003eIEC 61850 Support\u003c\/strong\u003e: Full implementation for Ed. 1 \u0026amp; 2\u003c\/li\u003e\n\u003cli data-start=\"364\" data-end=\"417\"\u003e\n\u003cstrong data-start=\"366\" data-end=\"384\"\u003eRoutable GOOSE\u003c\/strong\u003e: Supports wide area protection\u003c\/li\u003e\n\u003cli data-start=\"418\" data-end=\"480\"\u003e\n\u003cstrong data-start=\"420\" data-end=\"442\"\u003ePhasor Measurement\u003c\/strong\u003e: IEEE C37.118 synchrophasor support\u003c\/li\u003e\n\u003cli data-start=\"481\" data-end=\"541\"\u003e\n\u003cstrong data-start=\"483\" data-end=\"494\"\u003eDisplay\u003c\/strong\u003e: Large color screen for real-time monitoring\u003c\/li\u003e\n\u003cli data-start=\"542\" data-end=\"583\"\u003e\n\u003cstrong data-start=\"544\" data-end=\"559\"\u003eModular I\/O\u003c\/strong\u003e: Flexible I\/O options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"585\" data-end=\"603\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"604\" data-end=\"826\"\u003e\n\u003cli data-start=\"604\" data-end=\"658\"\u003e\n\u003cstrong data-start=\"606\" data-end=\"620\"\u003eGenerators\u003c\/strong\u003e: Steam, gas, and hydraulic turbines\u003c\/li\u003e\n\u003cli data-start=\"659\" data-end=\"704\"\u003e\n\u003cstrong data-start=\"661\" data-end=\"679\"\u003ePumped Storage\u003c\/strong\u003e: For reservoir storage\u003c\/li\u003e\n\u003cli data-start=\"705\" data-end=\"766\"\u003e\n\u003cstrong data-start=\"707\" data-end=\"729\"\u003eSubstation Control\u003c\/strong\u003e: Part of automated control systems\u003c\/li\u003e\n\u003cli data-start=\"767\" data-end=\"826\"\u003e\n\u003cstrong data-start=\"769\" data-end=\"789\"\u003eGE Installations\u003c\/strong\u003e: Standard protection for new units\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49709637075256,"sku":"G60","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/G60_1.jpg?v=1739444064"},{"product_id":"multilin-l90-ge-fanuc-line-current-differential-system","title":"Multilin L90 GE FANUC Line Current Differential System","description":"\u003ch3 data-start=\"0\" data-end=\"17\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"238\"\u003eThe \u003cstrong data-start=\"22\" data-end=\"47\"\u003eGE FANUC Multilin L90\u003c\/strong\u003e Line Current Differential System provides high-speed protection for transmission lines and cables across various voltage levels, supporting distance protection and dual-breaker applications.\u003c\/p\u003e\n\u003ch3 data-start=\"240\" data-end=\"258\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"259\" data-end=\"787\"\u003e\n\u003cli data-start=\"259\" data-end=\"341\"\u003e\n\u003cstrong data-start=\"261\" data-end=\"288\"\u003eDifferential Protection\u003c\/strong\u003e: High-speed phase-segregated, single-pole tripping\u003c\/li\u003e\n\u003cli data-start=\"342\" data-end=\"405\"\u003e\n\u003cstrong data-start=\"344\" data-end=\"367\"\u003eDistance Protection\u003c\/strong\u003e: 5 zones with customizable settings\u003c\/li\u003e\n\u003cli data-start=\"406\" data-end=\"487\"\u003e\n\u003cstrong data-start=\"408\" data-end=\"431\"\u003eSeries Compensation\u003c\/strong\u003e: Secure protection for lines with series compensation\u003c\/li\u003e\n\u003cli data-start=\"488\" data-end=\"560\"\u003e\n\u003cstrong data-start=\"490\" data-end=\"505\"\u003eSensitivity\u003c\/strong\u003e: Dynamic charging current and asymmetry compensation\u003c\/li\u003e\n\u003cli data-start=\"561\" data-end=\"623\"\u003e\n\u003cstrong data-start=\"563\" data-end=\"585\"\u003ePhasor Measurement\u003c\/strong\u003e: IEEE C37.118 synchrophasor support\u003c\/li\u003e\n\u003cli data-start=\"624\" data-end=\"694\"\u003e\n\u003cstrong data-start=\"626\" data-end=\"643\"\u003eCommunication\u003c\/strong\u003e: 3 Ethernet ports, 1 µs time sync with IEEE 1588\u003c\/li\u003e\n\u003cli data-start=\"695\" data-end=\"741\"\u003e\n\u003cstrong data-start=\"697\" data-end=\"714\"\u003eCybersecurity\u003c\/strong\u003e: “CyberSentry™” features\u003c\/li\u003e\n\u003cli data-start=\"742\" data-end=\"787\"\u003e\n\u003cstrong data-start=\"744\" data-end=\"757\"\u003eIEC 61850\u003c\/strong\u003e: Full Ed. 1 \u0026amp; Ed. 2 support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"789\" data-end=\"807\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"808\" data-end=\"1015\"\u003e\n\u003cli data-start=\"808\" data-end=\"892\"\u003e\n\u003cstrong data-start=\"810\" data-end=\"832\"\u003eTransmission Lines\u003c\/strong\u003e: High-speed protection for lines with series compensation\u003c\/li\u003e\n\u003cli data-start=\"893\" data-end=\"958\"\u003e\n\u003cstrong data-start=\"895\" data-end=\"910\"\u003eSubstations\u003c\/strong\u003e: Wide-area protection and control via R-GOOSE\u003c\/li\u003e\n\u003cli data-start=\"959\" data-end=\"1015\"\u003e\n\u003cstrong data-start=\"961\" data-end=\"977\"\u003eFlexible I\/O\u003c\/strong\u003e: Supports high-density, modular I\/O\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49709638910264,"sku":"L90","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/L90.jpg?v=1739443764"},{"product_id":"ge-multilin-l30-line-current-differential-system","title":"GE Multilin L30 | Line Current Differential System","description":"\u003ch3 data-start=\"0\" data-end=\"17\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-start=\"18\" data-end=\"223\"\u003eThe \u003cstrong data-start=\"22\" data-end=\"41\"\u003eGE Multilin L30\u003c\/strong\u003e Line Current Differential System offers reliable protection for sub-transmission and medium voltage lines, providing high-speed fault detection for three-pole tripping applications.\u003c\/p\u003e\n\u003ch3 data-start=\"225\" data-end=\"243\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"244\" data-end=\"691\"\u003e\n\u003cli data-start=\"244\" data-end=\"303\"\u003e\n\u003cstrong data-start=\"246\" data-end=\"273\"\u003eDifferential Protection\u003c\/strong\u003e: High-speed fault clearance\u003c\/li\u003e\n\u003cli data-start=\"304\" data-end=\"361\"\u003e\n\u003cstrong data-start=\"306\" data-end=\"323\"\u003eCommunication\u003c\/strong\u003e: RS422, G.703, C37.94, direct fiber\u003c\/li\u003e\n\u003cli data-start=\"362\" data-end=\"429\"\u003e\n\u003cstrong data-start=\"364\" data-end=\"386\"\u003ePhasor Measurement\u003c\/strong\u003e: IEEE C37.118 synchrophasor via Ethernet\u003c\/li\u003e\n\u003cli data-start=\"430\" data-end=\"470\"\u003e\n\u003cstrong data-start=\"432\" data-end=\"445\"\u003eIEC 61850\u003c\/strong\u003e: Ed. 1 \u0026amp; Ed. 2 support\u003c\/li\u003e\n\u003cli data-start=\"471\" data-end=\"516\"\u003e\n\u003cstrong data-start=\"473\" data-end=\"484\"\u003eR-GOOSE\u003c\/strong\u003e: Enables wide-area protection\u003c\/li\u003e\n\u003cli data-start=\"517\" data-end=\"589\"\u003e\n\u003cstrong data-start=\"519\" data-end=\"534\"\u003eSensitivity\u003c\/strong\u003e: Dynamic charging current and asymmetry compensation\u003c\/li\u003e\n\u003cli data-start=\"590\" data-end=\"644\"\u003e\n\u003cstrong data-start=\"592\" data-end=\"604\"\u003eSecurity\u003c\/strong\u003e: Adaptive restraint for CT saturation\u003c\/li\u003e\n\u003cli data-start=\"645\" data-end=\"691\"\u003e\n\u003cstrong data-start=\"647\" data-end=\"664\"\u003eCybersecurity\u003c\/strong\u003e: “CyberSentry™” features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"693\" data-end=\"711\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"712\" data-end=\"900\"\u003e\n\u003cli data-start=\"712\" data-end=\"791\"\u003e\n\u003cstrong data-start=\"714\" data-end=\"731\"\u003eVoltage Lines\u003c\/strong\u003e: Protection for sub-transmission and medium voltage lines\u003c\/li\u003e\n\u003cli data-start=\"792\" data-end=\"853\"\u003e\n\u003cstrong data-start=\"794\" data-end=\"816\"\u003eSubstation Control\u003c\/strong\u003e: Wide-area protection with R-GOOSE\u003c\/li\u003e\n\u003cli data-start=\"854\" data-end=\"900\"\u003e\n\u003cstrong data-start=\"856\" data-end=\"871\"\u003eI\/O Options\u003c\/strong\u003e: High-density, modular I\/O\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49709639795000,"sku":"L30","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/L30.jpg?v=1739443764"},{"product_id":"general-electric-multilin-ur-8hh-ur-8hh-ur8hh-ct-vt-module","title":"General Electric Multilin UR-8HH UR 8HH UR8HH CT\/VT Module","description":"\u003ch3 data-start=\"0\" data-end=\"21\"\u003e\u003cstrong data-start=\"4\" data-end=\"19\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"22\" data-end=\"296\"\u003eThe \u003cstrong data-start=\"26\" data-end=\"48\"\u003eGE Multilin UR-8HH\u003c\/strong\u003e is a CT\/VT module designed for installation in the Universal Relays series. It provides the relay with 1A\/5A ground CTs and 3-1A\/5A phase CTs, enabling accurate scaling of current and voltage ratings for system monitoring and protection functions.\u003c\/p\u003e\n\u003ch3 data-start=\"298\" data-end=\"320\"\u003e\u003cstrong data-start=\"302\" data-end=\"318\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"321\" data-end=\"527\"\u003e\n\u003cli data-start=\"321\" data-end=\"380\"\u003e\n\u003cstrong data-start=\"323\" data-end=\"342\"\u003eCurrent Inputs:\u003c\/strong\u003e 1A\/5A ground CTs, 3-1A\/5A phase CTs\u003c\/li\u003e\n\u003cli data-start=\"381\" data-end=\"449\"\u003e\n\u003cstrong data-start=\"383\" data-end=\"407\"\u003eRelay Compatibility:\u003c\/strong\u003e Designed for GE Universal Relays series\u003c\/li\u003e\n\u003cli data-start=\"450\" data-end=\"527\"\u003e\n\u003cstrong data-start=\"452\" data-end=\"468\"\u003eData Output:\u003c\/strong\u003e Monitors system conditions, outputs data for user review\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"529\" data-end=\"559\"\u003e\u003cstrong data-start=\"533\" data-end=\"557\"\u003eSoftware Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"560\" data-end=\"836\"\u003e\n\u003cli data-start=\"560\" data-end=\"645\"\u003e\n\u003cstrong data-start=\"562\" data-end=\"588\"\u003eEnerVista UR Software:\u003c\/strong\u003e Enables efficient configuration and data visualization\u003c\/li\u003e\n\u003cli data-start=\"646\" data-end=\"736\"\u003e\n\u003cstrong data-start=\"648\" data-end=\"684\"\u003eEnerVista Viewpoint UR Engineer:\u003c\/strong\u003e Drag-and-drop environment for rapid commissioning\u003c\/li\u003e\n\u003cli data-start=\"737\" data-end=\"836\"\u003e\n\u003cstrong data-start=\"739\" data-end=\"753\"\u003eInterface:\u003c\/strong\u003e Provides a user-friendly and well-organized display for settings and data review\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"838\" data-end=\"870\"\u003e\u003cstrong data-start=\"842\" data-end=\"868\"\u003eAdditional Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"871\" data-end=\"895\"\u003e\n\u003cli data-start=\"871\" data-end=\"895\"\u003e\n\u003cstrong data-start=\"873\" data-end=\"884\"\u003eWeight:\u003c\/strong\u003e 2.55 lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":49714868027704,"sku":"UR-8HH","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8HH_2.jpg?v=1739528054"},{"product_id":"735-5-5-hi-485-ge-multilin-feeder-protection-relay","title":"735-5-5-HI-485 GE Multilin Feeder Protection Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby GE Multilin is a feeder protection relay with a high-voltage power supply, suitable for distribution networks of various voltage levels.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 A CT for ground and phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485 2-wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Functions:\u003c\/strong\u003e\u003cbr\u003e• Phase and ground timed overcurrent\u003cbr\u003e• Phase and ground instantaneous overcurrent\u003cbr\u003e• Diagnosed lockout\u003cbr\u003e• Blocking instantaneous trips during autoreclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50976676839736,"sku":"735-5-5-HI-485","price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/735-5-5-HI-485_2.jpg?v=1754993697"},{"product_id":"ge-750-p1-g1-s1-hi-a20-r-feeder-management-relay","title":"GE 750-P1-G1-S1-HI-A20-R Feeder Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e750-P1-G1-S1-HI-A20-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE Fanuc is a feeder management relay that provides detailed monitoring of current inputs and clear control status indication.\u003c\/p\u003e\n\u003ch3\u003eCurrent Inputs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Current (P1):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Sequence Current (G1):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitive Ground Current (S1):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl Power\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e88–300 V DC or 70–265 V AC, 48–62 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAnalog Outputs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndicators\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRed LED signals breaker closed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50982377161016,"sku":"750-P1-G1-S1-HI-A20-R","price":470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/750-P1-G1-S1-HI-A20-R.jpg?v=1755078180"},{"product_id":"239-ge-multilin-motor-protection-relay","title":"239 GE Multilin Motor Protection Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin 239\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a motor protection relay providing accurate phase and ground current monitoring, advanced overload protection, and configurable trip curves.\u003c\/p\u003e\n\u003ch3\u003eCurrent Inputs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS, 16 samples per cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCT Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A and 5 A secondary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 to 11 × phase CT primary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20–300 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±2% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS, 16 samples per cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCT Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 A secondary and 50:0.025 CT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5 A CT: 0.03–1.4 × CT primary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50:0.025 CT: 0.05–16.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e0–0.49 A: ±0.03 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0.50–3.99 A: ±0.07 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4.00–16.00 A: ±0.20 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 A CT: ±2% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOverload Trip Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrip Curves:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 fixed-shape curves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Pickup Inhibit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable 1.00–5.00 × Full Load Current (FLC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePickup Level Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1–1500 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePickup: ±1% of displayed value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrip Time: ±2% of trip time or ±1 second, whichever is greater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50982393872696,"sku":"239","price":495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/239.jpg?v=1755078180"},{"product_id":"ge-ur-6av-multilin-universal-relay-digital-i-o-module","title":"GE UR 6AV Multilin Universal Relay Digital I\/O Module","description":"\u003ch2\u003eGE UR 6AV Multilin Universal Relay Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR 6AV\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR 6AV\u003c\/strong\u003e Digital I\/O Module, operates as a dedicated hardware component for contact output control and digital signal processing within GE Multilin Universal Relay platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Series\u003c\/td\u003e\n\u003ctd\u003eUR\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay Substation Platform Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Code\u003c\/td\u003e\n\u003ctd\u003e6AV\u003c\/td\u003e\n\u003ctd\u003eDigital Input \/ Contact Output Hardware Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Form\u003c\/td\u003e\n\u003ctd\u003eForm-A \/ Form-C\u003c\/td\u003e\n\u003ctd\u003eConfigurable Latching and Non-Latching Dry Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 6AV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 mm x 150 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Auxiliary Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Types\u003c\/td\u003e\n\u003ctd\u003eForm-A and Form-C Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Interface\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR Setup Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eInternal Backplane Bus \/ Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Communication \u0026amp; System Integration\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy the module into Universal Relay racks to execute low-latency trip signals and status contact switching across substation automation schemes. Furthermore, internal hardware optimization drives backplane bus communication velocity during high-density I\/O switching cycles. Consequently, system integrators expand digital contact density without degrading system response times or inter-relay teleprotection schemes. In addition, full firmware flash compatibility enables seamless online firmware sync across EnerVista configuration software environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What contact output configurations are provided on the UR 6AV module terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The board provides physical contact terminals configurable as Form-A (normally open) and Form-C (single-pole double-throw) output relays.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal architecture handle backplane bus loads during simultaneous relay energization?\u003c\/p\u003e\n\u003cp\u003eA: Power management circuitry regulates backplane current draw to prevent supply voltage drop during simultaneous high-speed switching events.\u003c\/p\u003e\n\u003cp\u003eQ: Is software configuration required prior to installing a replacement card in a live chassis?\u003c\/p\u003e\n\u003cp\u003eA: Yes, target card addresses and output logic profiles must match via EnerVista UR software to establish proper controller communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, technicians must completely isolate power to the host relay unit before inserting or removing the hardware card from the backplane rack. Next, align the card edges carefully with the chassis guides and push firmly until the backplane multi-pin connector seats completely. Tighten both front panel retaining screws to ensure proper mechanical bonding to the chassis frame. Furthermore, connect all external control loop wiring using twisted, shielded conductors separated from primary AC power buses to limit electromagnetic coupling. Finally, check all terminal block tension screws and verify ground wiring before re-energizing the auxiliary power supply.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51225149473080,"sku":"UR6AV","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6CH.jpg?v=1760160632"},{"product_id":"ur-8rh-ge-multilin-ur-series-current-input-module","title":"UR-8RH  | GE Multilin UR Series Current Input Module","description":"\u003ch2\u003eGeneral Electric UR-8RH CT Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-8RH\u003c\/strong\u003e is a dedicated current transformer input module developed for General Electric’s Multilin Universal Relay series. Designed specifically as a CT-only measurement option without voltage transformer inputs, it provides eight precision current-transformer channels with sensitive-ground fault detection for generator, transformer, motor, and feeder protection systems.\u003c\/p\u003e\n\u003ch3\u003eSignal Acquisition and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module features eight total current input channels, structured to accommodate 1 A or 5 A secondary ratings. This includes standard phase current inputs and a dedicated sensitive-ground CT input to capture low-magnitude fault currents in grounded or ungrounded power networks.\u003c\/p\u003e\n\u003ch3\u003eSystem Integration and Compatibility\u003c\/h3\u003e\n\u003cp\u003eAs a plug-in module for compatible UR relay chassis, the \u003cstrong\u003eUR-8RH\u003c\/strong\u003e integrates with Multilin UR platforms such as the F35, G60, C60, and T60, though it is not available for use with the C30 relay. Configuration, monitoring, and channel diagnostics are supported through the GE EnerVista UR software environment.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR-8RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin Universal Relay (UR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCT Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase CT Inputs\u003c\/td\u003e\n\u003ctd\u003e3 × 1 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround CT Input\u003c\/td\u003e\n\u003ctd\u003e1 × sensitive-ground, 1 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT Inputs\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Rating\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eGE EnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePlug-in module for compatible UR relay chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFeeder, transformer, generator, motor and line protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Does the GE UR-8RH module include voltage transformer inputs? A: No, the UR-8RH is a CT-only input module containing eight current transformer channels and no VT inputs.\u003c\/p\u003e\n\u003cp\u003eQ: What are the supported secondary current ratings for this module? A: It supports both 1 A and 5 A secondary connections for its current transformer inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Which GE Multilin Universal Relay models are compatible with the UR-8RH? A: It is compatible with UR Series relays such as the F35, G60, C60, and T60, but is not available for use with the C30 model.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51242070835512,"sku":null,"price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR8RH2.jpg?v=1760492498"},{"product_id":"489-p5-hi-a20-e-h-ge-multilin-489-generator-management-protection-relay","title":"489-P5-HI-A20-E-H | GE Multilin 489 Generator Management Protection Relay","description":"\u003ch2\u003eGeneral Electric 489-P5-HI-A20-E-H Generator Management Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE 489-P5-HI-A20-E-H\u003c\/strong\u003e is a generator management and protection relay from the Multilin 489 series, engineered to provide comprehensive electrical protection, thermal monitoring, and system control for synchronous generators. It safeguards medium to large generation assets against overcurrent, thermal overloads, voltage anomalies, and reverse power conditions.\u003c\/p\u003e\n\u003ch3\u003ePower Supply and Input Configuration\u003c\/h3\u003e\n\u003cp\u003eThis model is equipped with 5 A phase current transformer secondary inputs and supports a universal high-range auxiliary power supply operating on 70–265 VAC or 90–300 VDC across a 48–62 Hz frequency range. It also accommodates up to 12 RTD temperature sensor channels supporting platinum, nickel, and copper elements for continuous thermal tracking.\u003c\/p\u003e\n\u003ch3\u003eMetering and Analog Outputs\u003c\/h3\u003e\n\u003cp\u003eThe unit provides real-time metering capabilities for voltage, current, frequency, MW, Mvar, MVA, and power factor values. System integration and external data logging are supported via four isolated 4–20 mA analog outputs and serial communication interfaces including RS232 and RS485 using Modbus RTU protocol.\u003c\/p\u003e\n\u003ch3\u003eEnclosure and Environmental Adaptation\u003c\/h3\u003e\n\u003cp\u003eDesigned for panel mounting, the relay features a fully drawout case equipped with automatic current transformer shorting mechanisms for safe maintenance. It is protected by a harsh-environment conformal coating and operates reliably within a temperature range of -40 to +70 deg C.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e489-P5-HI-A20-E-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE) \/ Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMultilin 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGenerator Management Protection Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase CT Input\u003c\/td\u003e\n\u003ctd\u003e5 A secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Supply\u003c\/td\u003e\n\u003ctd\u003e70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Supply\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e48–62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 × 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 12 RTD channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eEnhanced LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Coating\u003c\/td\u003e\n\u003ctd\u003eHarsh-environment conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What auxiliary control power range does this relay support? A: It supports a universal power supply range of 70–265 VAC or 90–300 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit communicate with external control systems? A: It utilizes RS232 and RS485 communication interfaces running the Modbus RTU protocol.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51242211803448,"sku":"489-P5-HI-A20-E-H","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/489-P5-HI-A20-E-H.jpg?v=1760495261"},{"product_id":"ge-is200acleh1acb-is215acleh1a-ex2100-application-control-layer-module","title":"GE IS200ACLEH1ACB IS215ACLEH1A EX2100 Application Control Layer Module","description":"\u003ch2\u003eGE IS200ACLEH1ACB (IS215ACLEH1A) Application Control Layer Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200ACLEH1ACB\u003c\/strong\u003e (associated with assembly designation IS215ACLEH1A) is an Application Control Layer (ACLE) module engineered for General Electric EX2100 excitation control and Innovation Series drive control systems. Operating as a microprocessor-based master control and communication processor, it executes application-level control tasks while coordinating data exchange across Ethernet and serial network interfaces within dedicated GE control racks.\u003c\/p\u003e\n\u003ch3\u003eProcessing Architecture and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module integrates an embedded microprocessor supported by DRAM and non-volatile flash memory to handle system-level processing. It features two 10Base-T Ethernet ports and two RS-232 serial interfaces (COM1 and COM2) for system communication. Diagnostic capabilities are supported via front-panel LED indicators (OK, ACTIVE, ENET, FLASH, and STATUS) and a manual reset switch.\u003c\/p\u003e\n\u003ch3\u003eMechanical Configuration and Software Support\u003c\/h3\u003e\n\u003cp\u003eDesigned to occupy two slots within a dedicated GE EX2100 or Innovation Series control rack, the module relies on chassis cooling for thermal management. Configuration, diagnostics, and firmware management are performed using GE Toolbox and EX2100 control software environments, aligning with reference manual GEI-100434 and system user's guide GEH-6632.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Assembly Number\u003c\/td\u003e\n\u003ctd\u003eIS215ACLEH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer (ACLE) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eEX2100 Excitation Control \/ Innovation Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Function\u003c\/td\u003e\n\u003ctd\u003eMaster control and communication processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 ports (10Base-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 × RS-232 (COM1 and COM2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003eOK, ACTIVE, ENET, FLASH, STATUS LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDedicated GE EX2100 \/ Innovation Series control rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Occupancy\u003c\/td\u003e\n\u003ctd\u003eTwo slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e280 mm × 120 mm × 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the IS200ACLEH1ACB module? A: It functions as an Application Control Layer (ACLE) master control and communication processor within GE EX2100 excitation and Innovation Series drive systems.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are available on the module? A: It provides two 10Base-T Ethernet ports and two RS-232 serial ports (COM1 and COM2) for network and device communication.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module configured and monitored? A: Configuration, diagnostics, and software management are executed via GE Toolbox and EX2100 control software environments.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51320126243128,"sku":"IS200ACLEH1ACB(IS215ACLEH1A)","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/685.1.jpg?v=1793352135"},{"product_id":"application-control-layer-module-is200acleh1bcbis215acleh1b-ge","title":"Application Control Layer Module IS200ACLEH1BCB(IS215ACLEH1B) GE","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe GE IS200ACLEH1BCB, also known as IS215ACLEH1B, is a high-performance control module developed for gas and steam turbine automation. It belongs to the Mark VI control family and plays a central role in managing application-level logic, diagnostics, and system coordination. This module is typically installed in the EX2100 exciter rack and is engineered to operate reliably in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eMoreover, the ACLEH1BCB module supports real-time data handling and deterministic control, ensuring precise turbine operation under varying load conditions. In addition to its control capabilities, it offers backward compatibility with earlier system revisions, allowing seamless upgrades without major hardware changes. Engineers appreciate its modular design, which simplifies maintenance and system expansion.\u003c\/p\u003e\n\u003cp\u003eTherefore, the IS200ACLEH1BCB is widely used in mission-critical applications where uptime, safety, and performance are essential.\u003c\/p\u003e\n\u003ch2\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1BCB \/ IS215ACLEH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.75 cm × 9.50 cm × 3.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGas and Steam Turbine Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExecutes control logic for speed, load, and protection functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCoordinates turbine, generator, and exciter subsystems for stable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports distributed control in petrochemical and manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExcitation Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces with EX2100 modules for voltage regulation and fault handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Upgrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables backward-compatible enhancements to legacy Mark VI installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor instance, in a combined-cycle power plant, this module ensures synchronized control between gas and steam turbines, optimizing energy output and reducing downtime. In addition, its robust design supports continuous operation in high-temperature zones.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the main function of the IS200ACLEH1BCB module?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt executes application-level control logic and manages communication within GE Mark VI systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs this module compatible with older Mark VI components?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it offers backward compatibility for seamless system upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it be used in outdoor installations?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt should be housed in a protected rack environment, typically within control rooms or enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat software is used for configuration?\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE ToolboxST is used for setup, diagnostics, and firmware management.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat industries commonly use this module?\u003cbr\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustries include power generation, oil \u0026amp; gas, petrochemical, and heavy manufacturing.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51320207442232,"sku":"IS200ACLEH1BCB(IS215ACLEH1B)","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200ACLEH1BCB_IS215ACLEH1B.jpg?v=1762485866"}],"url":"https:\/\/www.automodulexpert.com\/collections\/ge-multilin.oembed?page=7","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}