{"title":"HIMA I\/O Modules","description":"\u003cp\u003e\u003cstrong\u003eHIMA I\/O modules\u003c\/strong\u003e are crucial components in safety-related control systems used across various industries. They serve as the interface between the control system and the physical world, receiving input signals from sensors and actuators and sending output signals to control devices.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"hima-f-3221-digital-input-module","title":"HIMA F 3221 Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eF 3221: 16-Fold Input Module Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Designed for connecting sensors or single signals\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e Includes safety isolation to ensure secure operation\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eCertification:\u003c\/strong\u003e SN-Test-Certificate 12 D 2\/H 19-66 R\/82\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e Non-interacting\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e1 signal, 8 mA (including cable plug)\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eMechanical contact 24 V\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSwitching Time:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003eTypical: 10 ms\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eSpace Requirement:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e4 TE\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eOperating Data:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e5 V DC: 70 mA\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\n\t\t\u003cp\u003e24 V DC: 130 mA\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cstrong\u003eR Non-interacting\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49093950177592,"sku":"F 3221","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/336e51e85435861ae6da547002cbc51c.jpg?v=1722938606"},{"product_id":"hima-f-3330-8-channel-output-module","title":"HIMA F 3330 8-Channel Output Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eF 3330: 8-Fold Output Module \u003c\/strong\u003e\u003c\/span\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Safety-related output module\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eResistive or inductive loads up to 500 mA (12 W)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLamp connections up to 4 W\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated safety shutdown\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSafe isolation\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eNo output signal if L- supply is interrupted\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eRequirement class AK 1 ... 6\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSelf-Test\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAutomatic testing during operation\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMain test routines include:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eReading back of output signals: The 0 signal operating point is ≤ 6.5 V. Faults may cause the 0 signal level to rise up to this value without detection.\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSwitching capability of test signal and cross-talking (walking-bit test)\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e: 500 mA, short circuit-proof\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInternal Voltage Drop\u003c\/strong\u003e: Max. 2 V at 500 mA load\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAdmissible Line Resistance (in + out)\u003c\/strong\u003e: Max. 11 Ohms\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eUndervoltage Tripping\u003c\/strong\u003e: ≤ 16 V\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Point for Short Circuit Current\u003c\/strong\u003e: 0.75 ... 1.5 A\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e: Max. 350 µA\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Voltage (if output is reset)\u003c\/strong\u003e: Max. 1.5 V\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDuration of Test Signal\u003c\/strong\u003e: Max. 200 µs\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e: 4 TE\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Data\u003c\/strong\u003e:\u003c\/span\u003e\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e5 V DC: 110 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e24 V DC: 180 mA (with additional load)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49093955584312,"sku":"F 3330","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/4141fa89c9dbf6b098daa764aafa63b1.jpg?v=1722938797"},{"product_id":"hima-f-3334-4-fold-output-module","title":"HIMA F 3334 4-Fold Output Module","description":"\u003ch3\u003e\u003cstrong\u003e \u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eF 3334: 4-Fold Output Module (F3334)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe F 3334 is a safety-related, 4-fold output module designed to handle both resistive and inductive loads up to 2 A (48 W) and lamp connections up to 25 W. This module includes integrated safety shutdown, safe isolation, and line monitoring, ensuring no output signal is present if the L- supply line breaks. Suitable for requirement classes AK 1 to AK 6, the F 3334 offers high reliability and enhanced safety features.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMaximum output current: \u003cstrong\u003e2 A\u003c\/strong\u003e, short-circuit proof\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eMaximum internal voltage drop: \u003cstrong\u003e2 V at 2 A load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eAdmissible line resistance (in + out): \u003cstrong\u003eUp to 3.6 Ω\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eUndervoltage tripping threshold: \u003cstrong\u003e≤ 16 V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eIntegrated line monitoring for:\u003c\/span\u003e\n\t\t\u003cul\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eShort-circuit current: \u003cstrong\u003e2.6 ... 5 A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eLine break detection: \u003cstrong\u003e0.5 ... 9.5 mA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003c\/ul\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOutput leakage current: \u003cstrong\u003eMaximum 550 µA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eOutput voltage when reset: \u003cstrong\u003eMaximum 1.5 V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower and Signal Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eCurrent input (watchdog): \u003cstrong\u003eMaximum 30 mA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eTest signal duration: \u003cstrong\u003eMaximum 250 µs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eSpace requirement: \u003cstrong\u003e4 TE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOperating Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e5 V DC\u003c\/strong\u003e: 130 mA\u003c\/span\u003e\u003c\/li\u003e\n\t\t\u003cli\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e: 130 mA (additional load)\u003c\/span\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49389371064632,"sku":"F 3334","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/add1693e94e2863319e1f53326ebd4a9.jpg?v=1730194461"},{"product_id":"hima-z7127-8-channel-analog-input-module-z-7127","title":"HIMA Z7127 8-Channel Analog Input Module Z 7127","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Z-Series\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Safety Control System (SIS)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003ePrimary Application:\u003c\/strong\u003e Used in safety-critical applications within industries such as chemical, oil and gas, power plants, and more.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eFunctionality:\u003c\/strong\u003e The Z7127 is capable of performing safety functions, including emergency shutdown (ESD), fire and gas detection, and burner management systems (BMS). The system supports redundancy and fault tolerance to enhance overall operational safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC (standard for industrial control systems)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e Typically ranges from -20°C to 60°C, depending on the specific model and configuration.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e Typically 5-95% non-condensing.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSafety Integrity Level (SIL):\u003c\/strong\u003e SIL 3 (according to IEC 61508).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Dual CPU and power supply options for fault tolerance.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eInputs\/Outputs:\u003c\/strong\u003e Configurable I\/O options, typically with both digital and analog inputs and outputs.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e The response time is system-dependent but is optimized for fast and reliable safety responses.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e TÜV and SIL certified for functional safety and reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49566565695800,"sku":"Z 7127","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/9d59176b04e2ac0847f325ec78d111dc.jpg?v=1735549904"},{"product_id":"hima-z7136-hiquad-digital-output-module-z-7136","title":"HIMA Z7136 HIQuad Digital Output Module Z 7136","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eZ 7136 HIQuad Digital Output Module\u003c\/strong\u003e is a high-integrity, fault-tolerant module used in safety-related systems. It provides four independent digital output channels, each capable of driving load signals to external devices. The HIQuad series from HIMA is designed to meet the high standards for functional safety and is typically used in industries such as oil \u0026amp; gas, chemical processing, and power generation, where safety-critical applications are required.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e Typically 24 VDC (depending on the specific model).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 4 independent digital output channels.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Typically voltage or current sourcing or sinking (depending on application).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 24 VDC nominal.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e Can handle up to 1 A per output channel (may vary based on configuration).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Internal self-diagnostics to detect hardware failures.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel isolation for improved safety.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eEnvironmental Rating:\u003c\/strong\u003e Designed for harsh industrial environments, with an operating temperature range of -20°C to +60°C.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e Compliance with functional safety standards, including IEC 61508 SIL 3, IEC 62061, and ISO 13849 PL e.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e Typically communicates with the HIMA controller via a robust communication bus.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDimensions (approx.):\u003c\/strong\u003e Standard size for HIQuad modules; usually a compact design for easy integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49566574182712,"sku":"Z 7136","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/973e837691f0e27a4fdc79eff37bfb0f.jpg?v=1735550476"},{"product_id":"digital-output-modules-hima-f-3331-h41q-h51q","title":"Digital Output Modules | HIMA F-3331 H41q H51q","description":"\u003ch2\u003eHIMA F 3331 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe HIMA \u003cstrong\u003eF 3331\u003c\/strong\u003e is an 8-channel digital output module designed for safety-related control and process automation applications. Operating on 24 VDC electronic outputs, it delivers up to 500 mA per channel to drive actuators, valves, and indicators in high-integrity system architectures. The module is engineered for integration within HIMA H41q and H51q safety platforms, supporting SIL 3 safety integrity levels and Category 4 safety configurations.\u003c\/p\u003e\n\u003ch3\u003eChannel Control and Signal Performance\u003c\/h3\u003e\n\u003cp\u003eEach of the 8 channels delivers 24 VDC electronic output capable of supporting up to 12 W resistive or inductive loads, or up to 4 W lamp loads. The internal voltage drop across an activated channel remains below 2 V at the full 500 mA rating. To protect system components, the outputs feature built-in short-circuit protection, limiting fault current between 0.75 A and 1.5 A, along with an automatic undervoltage shutdown when the supply drops to 16 V or lower.\u003c\/p\u003e\n\u003ch3\u003eMonitoring and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eIntegrated line monitoring continuously evaluates field loop integrity by tracking open-circuit and short-circuit conditions. Line-break detection operates within a 0.5 to 9.5 mA current window, while the module handles test pulses up to 200 us without disrupting field devices. Off-state leakage current is restricted to a maximum of 350 uA to prevent false actuation of downstream equipment.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF 3331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Category\u003c\/td\u003e\n\u003ctd\u003eSafety-Related Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eElectronic \/ Semiconductor Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e500 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Power\u003c\/td\u003e\n\u003ctd\u003e12 W (resistive or inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Load\u003c\/td\u003e\n\u003ctd\u003eUp to 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eCategory 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eMaximum 2 V at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible Line Resistance\u003c\/td\u003e\n\u003ctd\u003eMaximum 11 ohm (input and output combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Shutdown\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e0.75-1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-Break Detection Current\u003c\/td\u003e\n\u003ctd\u003e0.5-9.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 350 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Output Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 1.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatchdog Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Signal Duration\u003c\/td\u003e\n\u003ctd\u003eMaximum 200 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e130 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Power Consumption (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 100 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Space\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHIMA H41q \/ H51q\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHIMA I\/O Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What size load can each channel drive on the F 3331 module? A: Each channel supports up to 500 mA at 24 VDC, corresponding to a maximum of 12 W for resistive or inductive loads, or 4 W for lamp loads.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output short-circuit conditions? A: The module includes integrated short-circuit protection that limits output fault current to between 0.75 A and 1.5 A while shutting down under persistent low-voltage conditions.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489334296888,"sku":"F 3331","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F33311.jpg?v=1765246432"},{"product_id":"hima-f-7133-984713302-4-fold-power-distribution-module","title":"HIMA F 7133 984713302 4-Fold Power Distribution Module","description":"\u003ch2\u003eHIMA F 7133 Power Distribution Module\u003c\/h2\u003e\n\u003cp\u003eThe HIMA \u003cstrong\u003eF 7133\u003c\/strong\u003e (ordering number \u003cstrong\u003e984713302\u003c\/strong\u003e) is a four-channel 24 VDC power distribution unit engineered for safety-related control environments. Designed for mounting in HIMA I\/O subracks within H41q and H51q system architectures, it channels power to field devices, sensors, and module electronics. The module integrates miniature fuse protection for each individual circuit alongside electronic fuse monitoring to verify power path status.\u003c\/p\u003e\n\u003ch3\u003eCircuit Protection and Diagnostic Monitoring\u003c\/h3\u003e\n\u003cp\u003ePower distribution across the four channels is safeguarded by dedicated miniature slow-blow fuses rated up to 4 A each. An electronic monitoring circuit tracks the integrity of each fuse and drives individual visual LED fault indicators. When a fuse trips, the module isolates the circuit completely, resulting in 0 V residual voltage and 0 mA residual current downstream.\u003c\/p\u003e\n\u003ch3\u003eAlarm Relay Signaling\u003c\/h3\u003e\n\u003cp\u003eFor system-level diagnostics, the module incorporates a relay alarm output rated for 30 V and 4 A continuous load. The relay contact remains closed when all four fuses are present and intact; if any fuse is missing or blown, the relay de-energizes within approximately 100 ms to trip the fault signal. In the event of a total input supply loss, residual voltage is restricted to 3 V maximum with residual current under 1 mA.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF 7133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Number\u003c\/td\u003e\n\u003ctd\u003e984713302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e4-Fold Power Distribution Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Type\u003c\/td\u003e\n\u003ctd\u003eMiniature Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Fuse Rating\u003c\/td\u003e\n\u003ctd\u003e4 A, Slow-Blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Fuses\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated Electronic Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Indication\u003c\/td\u003e\n\u003ctd\u003eIndividual LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eRelay Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Switching Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 V \/ 4 A (continuous load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage (Fuse Tripped)\u003c\/td\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current (Fuse Tripped)\u003c\/td\u003e\n\u003ctd\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage (Supply Missing)\u003c\/td\u003e\n\u003ctd\u003eMaximum 3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current (Supply Missing)\u003c\/td\u003e\n\u003ctd\u003eLess than 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 x 100 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Space\u003c\/td\u003e\n\u003ctd\u003e4 TE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eHIMA H41q \/ H51q\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHIMA I\/O Subrack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: How does the F 7133 module signal a blown or missing fuse to the system controller? A: The module de-energizes its internal alarm relay contact within approximately 100 ms of a fuse fault, opening the circuit connected to the control monitoring loop.\u003c\/p\u003e\n\u003cp\u003eQ: What are the electrical ratings for the individual channel fuses on this module? A: Each of the four channels accepts a miniature slow-blow fuse rated up to a maximum of 4 A.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489339998520,"sku":"F 7133","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F71332.jpg?v=1765246431"},{"product_id":"hima-prohmn720434wizcon-31125132-1-safety-controller","title":"HIMA PROHMN720434WIZCON 31125132-1 Safety Controller","description":"\u003ch2\u003eHIMA PROHMN720434WIZCON 31125132-1 Industrial Safety Controller\u003c\/h2\u003e\n\u003cp\u003eThe HIMA \u003cstrong\u003ePROHMN720434WIZCON 31125132-1\u003c\/strong\u003e (model number \u003cstrong\u003ePROHMN720434WIZCON\u003c\/strong\u003e, part number \u003cstrong\u003e31125132-1\u003c\/strong\u003e) is an industrial safety controller engineered for safety-related process monitoring and control applications. Built for functional safety architectures under HIMA safety control systems, it executes protective logic and maintains operational oversight to support critical process safety loops.\u003c\/p\u003e\n\u003ch3\u003eFunctional Role and Environment\u003c\/h3\u003e\n\u003cp\u003eThis controller manages safety-related control functions to protect machinery and process equipment during critical operations. It operates across an ambient temperature range of -25 deg C to +70 deg C, making it suitable for installation within industrial control enclosures across demanding operating conditions.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePROHMN720434WIZCON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e31125132-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHIMA Paul Hildebrandt GmbH + Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Safety Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eSafety Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Function\u003c\/td\u003e\n\u003ctd\u003eSafety-related process monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial automation and safety systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHIMA safety-control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the main function of the HIMA PROHMN720434WIZCON 31125132-1 controller? A: It functions as an industrial safety controller, executing safety-related process monitoring and protective control logic.\u003c\/p\u003e\n\u003cp\u003eQ: What is the operating temperature range for this model? A: The module is rated for operation between -25 deg C and +70 deg C.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489450459448,"sku":"PROHMN720434WIZCON 31125132-1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PROHMN720434WIZCON_31125132-11.jpg?v=1765246432"},{"product_id":"32-channel-analog-input-module-hima-x-ai-32-01-himax","title":"32-Channel Analog Input Module | HIMA X-AI 32 01 HIMax","description":"\u003ch2\u003eHIMA X-AI 32 01 HIMax Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe HIMA \u003cstrong\u003eX-AI 32 01\u003c\/strong\u003e is a high-density 32-channel analog input module engineered for the HIMax programmable electronic safety platform. It acquires and processes 4-20 mA DC analog signals from field instruments, providing precise process monitoring and safety-related signal acquisition in critical automation architectures. Certified up to SIL 3 under IEC 61508, the module incorporates comprehensive line monitoring to ensure loop integrity between transmitters and the central controller.\u003c\/p\u003e\n\u003ch3\u003eSignal Processing and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe module processes up to 32 analog input channels, operating on standard 4-20 mA DC current loops with configurable signal ranges. Integrated line monitoring continuously checks field wiring for open circuits and line faults. Internal self-diagnostics execute real-time hardware checks and report errors via visual LED fault indicators, preventing unmonitored failures from affecting safety shutdown loops.\u003c\/p\u003e\n\u003ch3\u003ePower Supply and Physical Specifications\u003c\/h3\u003e\n\u003cp\u003eOperating on a 24 VDC nominal system supply (with an allowable tolerance of -15% to +20%), the module requires a minimum current consumption of 500 mA. Under transmitter-supply short-circuit conditions across field channels, current draw can rise up to 1.5 A, providing up to 30 mA per channel for transmitter powering. Housed in a standard 310 x 29.2 x 230 mm IP20 enclosure weighing approximately 1.4 kg, it mounts directly onto a HIMax system baseplate.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eX-AI 32 01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHIMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Monitoring\u003c\/td\u003e\n\u003ctd\u003eLine monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Supply\u003c\/td\u003e\n\u003ctd\u003eUp to 30 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15% to +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA min; up to 1.5 A under short-circuit conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61508, IEC 61511, IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance Level\u003c\/td\u003e\n\u003ctd\u003ePL e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMaximum 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e310 x 29.2 x 230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eHIMA HIMax system baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: How many analog signals can the HIMA X-AI 32 01 module process? A: The module features 32 high-density analog input channels designed for 4-20 mA DC current signals.\u003c\/p\u003e\n\u003cp\u003eQ: Does the X-AI 32 01 provide power supply to field transmitters? A: Yes, it supplies up to 30 mA per channel for connected field transmitters while supporting short-circuit protection on transmitter supply lines.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489462255928,"sku":"X-AI 32 01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/X-AI_32_01.jpg?v=1762930618"},{"product_id":"hima-f-3225-98-1322502-h41q-h51q-safety-digital-input-module","title":"HIMA F 3225 98 1322502 H41q H51q Safety Digital Input Module","description":"\u003ch2\u003eHIMA F 3225 Safety Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F 3225\u003c\/strong\u003e is a rack-mountable digital input module engineered for integration into HIMA H41q and H51q safety control platforms. It acquires binary status signals from field devices and processes them for safety-critical logic execution. Designed for plug-in installation into standard HIMA system subracks, the module features redundant safety communication paths and continuous internal diagnostic coverage to maintain high system availability and compliance with IEC 61508 functional safety standards.\u003c\/p\u003e\n\u003ch3\u003eSignal Processing and System Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe module captures field input states from external switching devices, such as limit switches, protective relays, emergency stop buttons, and digital interlocks. Field signals are electrically conditioned and filtered internally to suppress industrial electrical noise, contact bounce, and external transient interference before being passed to the central processor modules.\u003c\/p\u003e\n\u003cp\u003eIntegrated channel monitoring and diagnostic logic actively track input integrity. On-board status LEDs provide real-time diagnostic visual feedback for operational status and fault detection, facilitating rapid troubleshooting during maintenance routines.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF 3225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e98 1322502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety-Related Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System Platform\u003c\/td\u003e\n\u003ctd\u003eHIMA H41q \/ H51q Safety Instrumented Systems (SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003ePlug-in Rack Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Model\u003c\/td\u003e\n\u003ctd\u003eHIMA F 3236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cp\u003eQ: What safety system architectures support the HIMA F 3225 module? A: The module is designed for rack-mounted integration within HIMA H41q and H51q safety systems, communicating with the central processor units over the proprietary system I\/O bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module indicate channel faults or status changes?A: It features front-panel status and fault LEDs that display signal state updates and internal diagnostic alerts for fast visual inspection.\u003c\/p\u003e\n\u003cp\u003eQ: Is the HIMA F 3225 currently in active production? A: The F 3225 has reached discontinued status by the manufacturer, with the HIMA F 3236 designated as a compatible functional replacement module.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489493319992,"sku":"F 3225","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F32251.jpg?v=1765246433"},{"product_id":"industrial-automation-module-hima-f-7541-98-1754102-h41-h51","title":"Industrial Automation Module | HIMA F 7541 98 1754102 H41 H51","description":"\u003ch2\u003eHIMA F 7541 Industrial Automation Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F 7541\u003c\/strong\u003e is an industrial automation and interface module designed for integration into HIMA H41 and H51 safety-related control systems. It executes signal processing and system interfacing functions within safety instrumented systems and emergency shutdown applications. Installed via plug-in mounting into modular subracks such as the B 9301 rack, the unit supports reliable signal routing in mission-critical industrial process control environments.\u003c\/p\u003e\n\u003ch3\u003eInterface Processing and Subrack Installation\u003c\/h3\u003e\n\u003cp\u003eThe module operates as a core system interface unit, handling internal signal routing and conditioning between field instrumentation loops and central HIMA controller hardware. It is structured for direct rack-mounted installation within legacy H41 and H51 system chasses.\u003c\/p\u003e\n\u003cp\u003ePhysical dimensions and lightweight form factors accommodate dense modular arrangements within standard industrial control cabinets, supporting system maintenance and replacement procedures.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF 7541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e98 1754102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Automation Functional Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHIMA H41 \/ H51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Rack\u003c\/td\u003e\n\u003ctd\u003eB 9301 Subrack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e187 x 128 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg to 0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which controller series are compatible with the HIMA F 7541 module? A: The module is designed specifically for integration with HIMA H41 and H51 safety control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What type of subrack mounting does the module require? A: It utilizes a plug-in rack-mounted installation format designed for compatibility with the HIMA B 9301 subrack.\u003c\/p\u003e\n\u003cp\u003eQ: Is the HIMA F 7541 currently in active production? A: No, the module has been discontinued by the manufacturer, with an official end-of-life date recorded on December 31, 2010.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489525858616,"sku":"F 7541","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F75412.jpg?v=1765246433"},{"product_id":"x-di-32-01-hima-985210201-himax-sil-3-digital-input-module","title":"X-DI 32 01 HIMA 985210201 HIMax SIL 3 Digital Input Module","description":"\u003ch2\u003eHIMA X-DI 32 01 HIMax Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA X-DI 32 01\u003c\/strong\u003e is a high-density digital input module engineered for integration into HIMax safety-related control systems. It provides 32 dedicated digital input channels configured to acquire and monitor 24 VDC field signals from external safety devices. Designed for compliance with IEC 61508 SIL 3 functional safety standards, the module supports emergency shutdown systems and safety instrumented applications requiring continuous signal surveillance.\u003c\/p\u003e\n\u003ch3\u003eSignal Processing and Electrical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module processes incoming 24 VDC binary inputs using current-sinking logic, with defined voltage thresholds ranging from -3 V to 5 V for low states and 11 V to 30 V for high states. Input current draws under 1 mA without external loop supply, scaling up to 26 mA with active field power.\u003c\/p\u003e\n\u003cp\u003eAn integrated proximity switch supply delivers power across 8 distinct groups, supporting up to 4 outputs per group with a maximum supply current of 1.5 A. Continuous diagnostic monitoring and front-panel LED indicators track operational channel status and fault conditions.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eX-DI 32 01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e985210201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHIMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15% to +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003eCurrent-Sinking Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eHIMax Rack Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e310 x 29.2 x 230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What safety classification does the HIMA X-DI 32 01 module achieve? A: The module is certified for SIL 3 applications in compliance with IEC 61508 functional safety requirements.\u003c\/p\u003e\n\u003cp\u003eQ: How many field devices can be connected to a single module? A: It features 32 independent digital input channels designed to acquire 24 VDC signals.\u003c\/p\u003e\n\u003cp\u003eQ: What system rack architecture is required for installation? A: The module is engineered specifically for rack installation within the HIMax safety control system environment.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":51489553547576,"sku":"X-DI 32 01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/X-DI3201.jpg?v=1765246430"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/collections\/HIMA_I_O_Modules.png?v=1722996494","url":"https:\/\/www.automodulexpert.com\/collections\/hima-i-o-modules.oembed?page=2","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}