{"title":"YOKOGAWA Power Supply Module","description":"\u003cp\u003eYokogawa offers a range of high-quality power supply modules designed to support and enhance industrial automation systems. These modules are essential for providing stable and reliable power to various components within Yokogawa's automation systems, ensuring optimal performance and reliability.\u003c\/p\u003e\n\u003c!----\u003e","products":[{"product_id":"yokogawa-pw302-power-module","title":"YOKOGAWA PW302 Power Module","description":"\u003ch3\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe YOKOGAWA PW302 is a versatile power analyzer designed to provide comprehensive analysis and monitoring of electrical power systems. It is widely used in industrial and research applications for evaluating the performance and efficiency of electrical equipment. The PW302 offers precise measurement of electrical parameters, including voltage, current, power, and energy. Its user-friendly interface and advanced data processing capabilities make it suitable for both routine maintenance and detailed power analysis.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe analyzer is equipped with multiple measurement functions, including harmonics analysis and power quality assessment, which help in diagnosing electrical issues and ensuring system reliability. Its high accuracy and wide measurement range make it an ideal tool for both low and high voltage applications. The PW302 also supports data logging and real-time monitoring, providing valuable insights into the operational characteristics of electrical systems.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eWide Measurement Range\u003c\/strong\u003e: Capable of measuring a broad range of voltages and currents.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHigh Accuracy\u003c\/strong\u003e: Provides precise measurements with minimal error.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHarmonics Analysis\u003c\/strong\u003e: Analyzes harmonic distortion to assess power quality.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e: Records data over time for trend analysis and troubleshooting.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eReal-Time Monitoring\u003c\/strong\u003e: Offers live data visualization for immediate insights.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eUser-Friendly Interface\u003c\/strong\u003e: Easy-to-navigate display and controls.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVersatile Applications\u003c\/strong\u003e: Suitable for various industrial and research settings.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eVoltage Measurement\u003c\/strong\u003e: Up to 1000 V AC\/DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCurrent Measurement\u003c\/strong\u003e: Up to 30 A AC\/DC\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower Measurement\u003c\/strong\u003e: Active, reactive, and apparent power\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 45 to 65 Hz\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eHarmonic Analysis\u003c\/strong\u003e: Up to the 50th harmonic\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: LCD screen with graphical interface\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e: Internal memory with export options\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e: USB, RS-232, LAN\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.1% of reading (typical)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: AC 100-240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\u003c\/span\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49077404795192,"sku":"PW302","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/8387850f5ff4697b0e5c083027fd0c50.jpg?v=1722504270"},{"product_id":"yokogawa-pw482-10-power-supply-module","title":"YOKOGAWA PW482-10 Power Supply Module","description":"\u003ch2\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003eThe module is compatible with Field Control Units (FCUs), FIO Node Units, or Optical ESB Bus Repeater Units. A dual-redundant power supply configuration can be achieved by installing two modules.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"222\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"158\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003ePW481\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003ePW482\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003ePW484\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"222\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInput Power Supply Voltage\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"158\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e100-120 V AC ± 10%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e50\/60 Hz ± 3 Hz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e220-240 V AC ± 10%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e50\/60 Hz ± 3 Hz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e24 V DC ± 10%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"222\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eMaximum Power Consumption\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"158\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e200 VA\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e230 VA\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e5.5 A\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"222\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"158\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eApprox. 1 kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eApprox. 1 kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eApprox. 1 kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"222\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInput\/Output Interface\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"158\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eExclusive Connector\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eExclusive Connector\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"168\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eExclusive Connector\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49077420949816,"sku":"PW482-10","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ae1b8c4adae95fa6e31e0deb4ad78a20.jpg?v=1722504572"},{"product_id":"yokogawa-spw482-53-power-supply-module","title":"YOKOGAWA SPW482-53 Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eA power supply module is connected to either a 100-120 V AC, 220-240 V AC, or 24 V DC main power source. It provides insulated +5 V and +24 V outputs to each installed I\/O module via the backplane. These outputs support dual-redundant insulated operation for increased reliability. The available power supply modules for the ProSafe-RS system include the following models:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eSPW481: 100-120 V AC\u003c\/li\u003e\n\t\u003cli\u003eSPW482: 220-240 V AC\u003c\/li\u003e\n\t\u003cli\u003eSPW484: 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49198776353080,"sku":"SPW482-53","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/0d9aadba0c1af96b438a914f094811f1.jpg?v=1725525448"},{"product_id":"yokogawa-spw481-13-power-supply-module","title":"YOKOGAWA SPW481-13 Power Supply Module","description":"\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003eThe Yokogawa SPW481-13 is a component commonly used in industrial automation systems, specifically within control systems and process automation. It is known for its reliability and performance in monitoring and controlling various processes in industries such as oil and gas, chemical, and power generation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\n\n\u003ch3\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003c\/span\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e SPW481-13\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Power Supply Module\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 100-120V AC\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli\u003e\n\t\u003cp\u003e\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 2.5 Amps\u003c\/span\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan style=\"font-family:Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49250462662968,"sku":"SPW481-13","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/660cced3ed9e50e6b73c6ce09192849b.jpg?v=1726506066"},{"product_id":"yokogawa-pw502-power-supply-unit","title":"YOKOGAWA PW502 Power Supply Unit","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA PW502 \u003c\/strong\u003ePower Supply Unit is an essential component for powering various devices within a control system, particularly repeaters. It offers a reliable and stable power source to ensure optimal performance of connected equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Power Supply Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose\u003c\/strong\u003e: For repeater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 220 to 240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 50°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49256603320632,"sku":"PW502","price":201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW502.jpg?v=1726657714"},{"product_id":"yokogawa-pw402-power-supply","title":"YOKOGAWA PW402 Power Supply","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA PW402 Power Supply\u003c\/strong\u003e is a reliable and efficient power source tailored for Yokogawa Centum CS and Centum VP control systems. It ensures the necessary power supply for various components within these systems, supporting their optimal operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: Yokogawa Centum CS - Centum VP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5.1 cm x 22.9 cm x 20.3 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 2.0 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49256605024568,"sku":"PW402","price":201.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW402.jpg?v=1726657843"},{"product_id":"yokogawa-f3pu10-0s-power-supply-module","title":"YOKOGAWA F3PU10-0S Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe YOKOGAWA \u003cstrong\u003eF3PU10-0S\u003c\/strong\u003e Power Supply Module is a reliable and efficient power source designed for use in industrial automation and control systems. It provides a stable and regulated DC voltage output for powering various electronic components and devices.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 100-240 V AC, single phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage Fluctuation Range:\u003c\/strong\u003e 85-264 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 35 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 20 A max. (120 V AC, Ta=25°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Voltage:\u003c\/strong\u003e 5 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Current:\u003c\/strong\u003e 2.0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e 5 MΩ or more at 500 V DC (between external AC terminals and FG terminal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 1500 V AC for 1 minute (between external AC terminals and FG terminal)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAllowable Momentary Power Failure Time:\u003c\/strong\u003e 20 ms (Standard Mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e 1500 Vp-p\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Dimensions:\u003c\/strong\u003e 28.9 (W) x 100 (H) x 83.2 (D) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 190 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironment Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding Air Temperature Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: 0 to 55°C\u003c\/li\u003e\n\u003cli\u003eStorage: -20°C to 75°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding Humidity Range:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOperating: 10 to 90% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003eStorage: 10 to 90% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding Atmosphere:\u003c\/strong\u003e Must be free of corrosive gases, flammable gases, or heavy dust.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49260004475192,"sku":"F3PU10-0S","price":222.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F3PU10-0S.jpg?v=1726735475"},{"product_id":"yokogawa-pw482-50-power-supply-module","title":"YOKOGAWA PW482-50 Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe YOKOGAWA \u003cstrong\u003ePW482-50\u003c\/strong\u003e Power Supply Module is a reliable and efficient device designed to provide power to various industrial automation components. It offers a wide input voltage range and multiple configuration options to suit different application requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct No.:\u003c\/strong\u003e PW482-50\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e PW482 = 220 - 240 V AC Input Power Supply Module (with Temperature (-20°C to 70°C) Option)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix Codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5:\u003c\/strong\u003e Standard type with no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0:\u003c\/strong\u003e Basic type\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49264572170552,"sku":"PW482-50","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW482-50.jpg?v=1726823352"},{"product_id":"yokogawa-pw481-10-power-supply-module","title":"YOKOGAWA PW481-10 Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe YOKOGAWA \u003cstrong\u003ePW481-10\u003c\/strong\u003e Power Supply Module is a reliable and efficient device designed to provide power to various Yokogawa automation components. It offers a wide input voltage range and is compatible with Yokogawa Centum CS - Centum VP systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel(s):\u003c\/strong\u003e Yokogawa Centum CS - Centum VP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Supply Voltage:\u003c\/strong\u003e 100~120 V AC ± 10 %, 50\/60 Hz ± 3 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power Consumption:\u003c\/strong\u003e 200 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\/Output Interface:\u003c\/strong\u003e Exclusive connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.0\" x 8.0\" x 6.0\" (5.1 cm x 20.3 cm x 15.2 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 lbs 16.0 oz (0.9 kg)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49264692855096,"sku":"PW481-10","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW481-10.jpg?v=1726825472"},{"product_id":"yokogawa-pw702-power-supply-module","title":"YOKOGAWA PW702 Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003ePW702\u003c\/strong\u003e is a power supply module designed to provide reliable power to Yokogawa Centum CS and Centum VP field control stations, essential for their operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Yokogawa Centum CS - Centum VP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e 220-240V AC, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e DC +5.1V, 29A, 147.9W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 10.0\" x 3.0\" x 11.0\" (25.4 cm x 7.6 cm x 27.9 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 lbs 6.1 oz (2.0 kg)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49274953957688,"sku":"PW702","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW702.jpg?v=1727081162"},{"product_id":"yokogawa-nfpw442-50-power-supply-module","title":"YOKOGAWA NFPW442-50 Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFPW442-50\u003c\/strong\u003e is a versatile power supply module designed for use in industrial control systems. It provides reliable power to connected devices, ensuring stable operation even in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Input\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e: 220 to 240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 170 to 264 V AC (rms)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency\u003c\/strong\u003e: 47 to 66 Hz (Rating: 50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current\u003c\/strong\u003e: Max. 0.7 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating\u003c\/strong\u003e: 3.15 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRush Current\u003c\/strong\u003e: Max. 90 A for 5 ms or less\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak Current\u003c\/strong\u003e: Max. 1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e: 500 V AC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e: 50 MΩ at 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsensitive Momentary Power-Failure Time\u003c\/strong\u003e: 2 ms (90%)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e: +5.1 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Current\u003c\/strong\u003e: 0 to 7.8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Current\u003c\/strong\u003e: 11.8 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Output\u003c\/strong\u003e: 40 W (60 W peak)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStartup Time After Power-On\u003c\/strong\u003e: Max. 100 ms (after a power failure of 200 ms long with the rated input)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e: Max. 7 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e: Min. 105% (shutdown after 4 to 14 seconds long overcurrent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Field Power Supply\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e: 24 V DC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current\u003c\/strong\u003e: Max. 4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating\u003c\/strong\u003e: 6.3 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Voltage\u003c\/strong\u003e: Input voltage minus matching-diode drop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Current\u003c\/strong\u003e: 4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e: 35 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDuplex Configuration\u003c\/strong\u003e: Possible (when installed on base module NFBU200)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.6 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 49.7 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 130 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 146.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49344692683064,"sku":"NFPW442-50","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFPW442-50.jpg?v=1729063846"},{"product_id":"yokogawa-pw484-51-power-module","title":"YOKOGAWA PW484-51 Power Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe YOKOGAWA \u003cstrong\u003ePW484-51\u003c\/strong\u003e is a Power Supply Module designed to provide stable and reliable power for industrial control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V DC Output\u003c\/strong\u003e: ±10% voltage stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Capacity\u003c\/strong\u003e: 5.5 A output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExclusive Connector\u003c\/strong\u003e: Ensures secure and reliable connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Type\u003c\/strong\u003e: No explosion protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISA Standard G3 Option\u003c\/strong\u003e: Available with temperature range (-20°C to 70°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 100-120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 24 V DC ± 10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e: 5.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e: 200 VA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -20°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e: -25°C to 80°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 282 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 210 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 1 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49392859021624,"sku":"PW484-51","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW484-51_2.jpg?v=1730254930"},{"product_id":"ps13-b-yokogawa-power-supply-unit","title":"PS13*B | YOKOGAWA | Power Supply Unit","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePS13*B\u003c\/strong\u003e is a reliable industrial power supply unit from Yokogawa, designed to provide stable and efficient power in demanding automation applications.\u003c\/p\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 100-240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 5 VDC to 48 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e High efficiency for reduced energy consumption and heat generation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Features:\u003c\/strong\u003e Overcurrent, overvoltage, and short circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Compact design for efficient panel space usage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 120 g (0.26 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Flexibility:\u003c\/strong\u003e Multiple mounting options for ease of installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":49465469534520,"sku":"PS13*B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PS13B_1.jpg?v=1732182949"},{"product_id":"spw481-53-yokogawa-power-supply-module","title":"SPW481-53 | Yokogawa Power Supply Module","description":"\u003ch3 class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSPW481-53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a reliable power supply module designed for industrial applications, ensuring stable and efficient voltage regulation.\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Yokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eProduct No.\u003c\/strong\u003e: SPW481-53\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: SPW481 = 100-120V AC Input Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e: Standard type with no explosion protection (5)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEnvironmental Standard\u003c\/strong\u003e: ISA Standard G3 compliant with temperature range (-20°C to +70°C) (1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 100-120V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: Regulated DC output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":50181266669880,"sku":"SPW481-53","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SPW481-53_1.jpg?v=1746695412"},{"product_id":"power-supply-module-yokogawa-pw301-s3-centum","title":"Power Supply Module | Yokogawa PW301 S3 CENTUM","description":"\u003ch2\u003eYokogawa PW301 S3 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa PW301 S3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW301\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for stable DC voltage bus distribution within CENTUM control system racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW301 S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa cabinet slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (Power Output Provider)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Types\u003c\/td\u003e\n\u003ctd\u003eOvercurrent and overvoltage safeguards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail \/ Rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Power Integrity and Loop Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module regulates primary AC mains input down to stable DC voltage rails required by internal system backplanes and field devices. Integrated suppression networks eliminate high-frequency electrical noise and supply transients before power reaches sensitive DCS processor components. Isolated power rails maintain channel-to-channel isolation parameters across remote instrumentation networks, shielding 4-20 mA HART loop communication paths from common-mode voltage spikes and potential ground loop interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the PW301 S3 respond to downstream overcurrent fault conditions?\u003c\/p\u003e\n\u003cp\u003eA: The module triggers internal electronic current limiting when load limits are exceeded, preventing thermal damage to the internal transformer and auto-resetting once the fault clears.\u003c\/p\u003e\n\u003cp\u003eQ: Can the PW301 S3 be installed in high-vibration control enclosures?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the mechanical chassis includes vibration-resistant locking mechanisms that maintain electrical continuity with the mounting rail under standard industrial cabinet vibration profiles.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the PW301 S3 vertically inside the control enclosure to facilitate natural convection airflow across the power heat sinks. Maintain minimum clearance distances above and below the module housing as specified in the enclosure mechanical layout manual. Verify that the AC supply circuit breaker is open before connecting power leads to the primary terminal block.\u003c\/p\u003e\n\u003cp\u003eGround the module chassis directly to the main cabinet ground busbar using a short, low-impedance grounding strap. Ensure all AC supply wiring follows local code requirements for current capacity and isolation rating. Tighten terminal connection screws securely to achieve a gas-tight electrical bond resistant to thermal cycling and operational vibration.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51175634796856,"sku":"PW301 S3","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW301_S31.jpg?v=1759042727"},{"product_id":"yokogawa-anb10d-410-ndel-centum-vp-node-interface-unit","title":"YOKOGAWA ANB10D-410\/NDEL CENTUM VP Node Interface Unit","description":"\u003ch2\u003eYOKOGAWA ANB10D-410\/NDEL Node Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA ANB10D-410\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e Node Interface Unit, operates as a dedicated hardware component for high-speed bus arbitration and node-to-node communication within YOKOGAWA CENTUM DCS networks. Mounted within the subrack assembly, the card interfaces local I\/O modules directly with the central control station over dual-redundant network paths. This physical execution provides real-time data frame transmission, low-latency node synchronization, and continuous bus signal conditioning across distributed automation topologies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification \u0026amp; Hardware Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant node interface unit base module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual power supply module interface capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard ISA Standard G3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlways 0 (Basic specification type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo dual ESB bus interface \/ Node connection expansion license option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-410\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa node subrack slot enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP \/ ESB Bus Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connectors\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ45 and Coaxial BNC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Redundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant physical layer execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Integration \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for process control architecture, the ANB10D-410\/NDEL integrates galvanic channel-to-channel isolation to prevent ground loop currents across long fieldbus distances. The onboard communication controller processes 4-20 mA HART loop protocol pass-through signals while supporting high-density FOUNDATION Fieldbus and Profibus PA connectivity at the backplane boundary. Integrated digital filtering and automatic cold junction compensation (CJC) signal passing prevent noise coupling from entering system control processors, maintaining signal purity across noisy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the ANB10D-410\/NDEL handle network redundancy during a physical media fault?\u003c\/p\u003e\n\u003cp\u003eA: The module executes hardware-level failover switching between primary and secondary coaxial or Ethernet bus lines in microseconds, preventing communication dropouts during physical line disruption.\u003c\/p\u003e\n\u003cp\u003eQ: What power rail dependencies exist for the ANB10D-410\/NDEL inside the node unit?\u003c\/p\u003e\n\u003cp\u003eA: The card draws power directly from the subrack backplane power bus, operating with a total thermal dissipation profile capped at a maximum of 12 W under full bus load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the ANB10D-410\/NDEL firmly into its assigned subrack node slot before securing all panel retention screws to ensure a continuous low-impedance ground path to the system cabinet frame. Always disconnect system subrack power prior to module insertion or removal to prevent electrical transient damage to the backplane edge connectors.\u003c\/p\u003e\n\u003cp\u003eRoute coaxial BNC and Ethernet network communication cables through dedicated, grounded wire trunks physically separated from three-phase AC power lines, motor leads, and variable frequency drives. Ground all cable shields at a single dedicated system ground bus bar to eliminate ground loop currents, and adhere strictly to minimum cable bending radii to prevent signal reflection issues along the network bus.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178804740408,"sku":"ANB10D-410\/NDEL","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/301.jpg?v=1788489948"},{"product_id":"yokogawa-pw504-centum-vp-cs-3000-power-supply-unit","title":"YOKOGAWA PW504 CENTUM VP CS 3000 Power Supply Unit","description":"\u003ch2\u003eYOKOGAWA PW504 Power Supply Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for internal bus voltage regulation in YOKOGAWA CENTUM VP and CENTUM CS 3000 control systems, the \u003cstrong\u003eYOKOGAWA PW504\u003c\/strong\u003e (\u003cstrong\u003ePW504\u003c\/strong\u003e Power Supply Unit) provides direct physical\/electrical execution. The module converts AC line voltage into a regulated 5 VDC rail output to drive rack-mounted controllers, I\/O cards, and communication processors across backplane buses. By delivering continuous power conditioning and surge suppression, the hardware maintains backplane logic stability under varying electrical loads.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification \u0026amp; Hardware Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePW504\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase model power supply unit for CENTUM subrack assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 5 VDC backplane output configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle power feed execution (Non-redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power feed interface capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa subrack power slot enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC \/ 200-240 VAC (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-density DCS deployment, the PW504 incorporates galvanic isolation between primary AC line inputs and low-voltage secondary DC outputs to safeguard system processors from line transients. The unit maintains stable 5 VDC supply rails that support downstream fieldbus communications, including 4-20 mA HART loop protocol translation, FOUNDATION Fieldbus signal routing, and Profibus PA interface cards. Integrated filter networks minimize high-frequency ripple, preventing power-line noise coupling into analog input measurement channels and cold junction compensation (CJC) circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the PW504 handle AC input voltage selection between 100-120 VAC and 200-240 VAC ranges?\u003c\/p\u003e\n\u003cp\u003eA: Voltage range selection relies on proper terminal wiring terminal configurations or internal jumper settings on the module side prior to energizing the unit.\u003c\/p\u003e\n\u003cp\u003eQ: Can two PW504 modules operate in a dual-redundant power configuration within the same subrack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, when installed in designated dual-power slots on compatible subrack backplanes, two PW504 modules share the load and execute active hot-standby power failover.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the PW504 securely into the designated power supply slot on the subrack assembly, tightening the top and bottom retaining screws to establish frame grounding. Always isolate AC main power feeds before installing or replacing the power module to eliminate physical shock hazards and connector arcing.\u003c\/p\u003e\n\u003cp\u003eRoute incoming AC power conductors through dedicated wire raceways separated from sensitive DC signal lines and coaxial communication cables. Ensure the protective earth (PE) grounding conductor connects directly to the cabinet ground bar using a low-impedance connection to guarantee noise suppression and electrical safety.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178849796408,"sku":"PW504","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PW504.jpg?v=1759110117"},{"product_id":"anb10d-421-cu2n-ndel-yokogawa-node-interface-unit","title":"ANB10D-421\/CU2N\/NDEL Yokogawa Node Interface Unit","description":"\u003ch2\u003eYokogawa ANB10D-421 CENTUM Node Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-421\/CU2N\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D-421\u003c\/strong\u003e Node Interface Unit, operates as a dedicated hardware component for dual-redundant data communication execution within Yokogawa CENTUM platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP bus interface connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eNode Option\u003c\/td\u003e\n\u003ctd\u003eStandard node mounting without explosion-proof barrier options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM node unit footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet, coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eDual-redundant Vnet\/IP bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDual-Redundant Vnet\/IP Bus Communication \u0026amp; DCS Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe module hosts dual coaxial and Ethernet physical interfaces to support deterministic Vnet\/IP communication between central control stations and remote I\/O nests. Internal channel-to-channel isolation safeguards backplane data pathways against common-mode noise propagation and voltage surges originating from long field network runs. Integrated diagnostic circuitry continuously checks transmission line signal integrity across both primary and secondary communication paths. When line attenuation or open-circuit conditions occur on the primary channel, the unit executes an immediate hardware failover to the secondary bus without interrupting real-time DCS process control loops or cyclic data polling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module maintain network communication during a bus line physical failure?\u003c\/p\u003e\n\u003cp\u003eA: The onboard dual-redundant communication controller monitors signal levels on both active and standby channels simultaneously. If link loss occurs on the primary bus, the hardware switches traffic to the secondary channel within microseconds to prevent node offline timeouts.\u003c\/p\u003e\n\u003cp\u003eQ: What power budget considerations apply when installing the ANB10D-421\/CU2N\/NDEL in a control cabinet?\u003c\/p\u003e\n\u003cp\u003eA: The unit consumes 15 W at steady-state operation. Ensure cabinet power distribution units account for this heat output and current draw alongside connected node supply units.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main power feed supplies to the enclosure node rack are de-energized before mounting the unit. Align the module base housing with the cabinet mounting rail slots and tighten retaining fasteners securely to maintain chassis grounding integrity.\u003c\/p\u003e\n\u003cp\u003eFor bus network installation and wiring:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConnect primary and secondary coaxial or Ethernet cables to the designated \/CU2N interface connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain specified minimum bending radii for network cables during bundle routing inside cabinet channels to prevent signal reflection.\u003c\/li\u003e\n\u003cli\u003eVerify that coaxial cable shield connectors link directly to system ground at the bus termination points; do not permit floating shield connections.\u003c\/li\u003e\n\u003cli\u003eSeparate network communication lines from high-current AC power wiring runs by at least 200 mm to avoid inductive coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178876272952,"sku":"ANB10D-421\/CU2N\/NDEL","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANB10D-421CU2NNDEL2.jpg?v=1759110117"},{"product_id":"yokogawa-pw442-50-prosafe-rs-series-24-v-dc-power-supply-module","title":"Yokogawa PW442-50 ProSafe-RS Series 24 V DC Power Supply Module","description":"\u003ch2\u003eYokogawa PW442-50 ProSafe-RS Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa PW442-50\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW442\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for continuous DC voltage generation and internal backplane bus energization within Yokogawa ProSafe-RS safety instrumented systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW442-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ProSafe-RS rack module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC or 200-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e4 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant diode OR-ing parallel operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation \u0026amp; Safety Instrumented System Integrity\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes high-grade internal galvanic isolation transformer stages to decouple incoming primary AC mains from downstream 24 V DC safety system logic circuits. Integrated decoupling diodes allow dual PW442-50 units to operate in active 1+1 redundant configurations without common-mode power failure propagation. Internal sensing circuitry continuously tracks primary AC feed stability and output DC rail integrity, transmitting real-time voltage status flags to the ProSafe-RS central processing unit via isolated backplane diagnostic lines. If an AC supply dip or internal component failure occurs on one module, the redundant power unit instantly assumes the full load current demand without introducing voltage transients to connected safety logic cards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the PW442-50 module be replaced online while the ProSafe-RS safety instrumented system is fully operational?\u003c\/p\u003e\n\u003cp\u003eA: Yes. When installed in a dual-redundant configuration, the module supports hot-swapping. You can extract a faulted module and insert a new unit without interrupting the 24 V DC system power rail or causing process trips.\u003c\/p\u003e\n\u003cp\u003eQ: What primary AC input voltage selection steps are required before energizing the module?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts wide-range AC inputs (100-120 V AC or 200-240 V AC). Ensure incoming field power cables match the terminal rail specifications and that supply fusing complies with cabinet design limits before energizing the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eIsolate external AC supply breakers before mounting or servicing the unit. Align the rear module frame with the ProSafe-RS base rack guide tracks and push firmly until the locking mechanisms seat fully into the backplane.\u003c\/p\u003e\n\u003cp\u003eFor power wiring and cabinet commissioning:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eStrip primary AC line, neutral, and ground conductors to 7 mm and land them securely into the designated screw terminal connections.\u003c\/li\u003e\n\u003cli\u003eConnect the primary protective earth (PE) terminal directly to the main cabinet enclosure copper earth busbar using low-impedance cabling.\u003c\/li\u003e\n\u003cli\u003eKeep AC input power feed cabling strictly separated from internal 24 V DC field signal wiring ducts to prevent capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify terminal screw retention torque to ensure low-resistance electrical contact and prevent thermal hot spots during full 4 A current load operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178883023160,"sku":"PW442-50","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI543-S031.jpg?v=1759110118"},{"product_id":"16-channel-temperature-transmitter-module-yokogawa-ati3s-001","title":"16-Channel Temperature Transmitter Module Yokogawa ATI3S-001","description":"\u003ch2\u003eYokogawa ATI3S-001 ProSafe-RS Temperature Transmitter Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ATI3S-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eATI3S\u003c\/strong\u003e Temperature Transmitter Module, operates as a dedicated hardware component for 16-channel isolated temperature signal acquisition within Yokogawa ProSafe-RS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATI3S-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ProSafe-RS rack module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD and Thermocouple sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC analog current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates dedicated internal cold junction compensation (CJC) circuits alongside galvanic channel-to-channel isolation across all 16 input paths. When processing low-millivolt thermocouple signals, onboard CJC sensors continuously monitor terminal block temperature gradients to eliminate cold junction reference drift. Galvanic isolation prevents ground loop currents and field transients from corrupting temperature measurement accuracy or propagating backplane disturbances into adjacent safety system processing channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle a sensor burnout or open-circuit condition on a thermocouple channel?\u003c\/p\u003e\n\u003cp\u003eA: Upon detecting an open-circuit fault or sensor failure, internal diagnostic circuits immediately drive the corresponding channel output to a predefined upscale or downscale safe state, notifying the ProSafe-RS controller of the fault condition.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be inserted or removed under power during routine maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The ATI3S-001 supports hot-swapping within ProSafe-RS I\/O racks, permitting module replacement without interrupting operating power or signal conversion on adjacent active system cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main enclosure power is isolated before mounting the module into the designated slot. Align the rear edge connectors with the backplane guide rails and press firmly until the mechanical locking tabs engage fully.\u003c\/p\u003e\n\u003cp\u003eFor sensor signal wiring and cabinet commissioning:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eStrip thermocouple or RTD field extension leads to 7 mm and land conductor ends securely into the terminal block.\u003c\/li\u003e\n\u003cli\u003eConnect thermocouple extension wires using matching alloy leads to maintain cold junction measurement integrity.\u003c\/li\u003e\n\u003cli\u003eRoute sensor cabling in dedicated low-voltage instrument ducts separate from AC power circuits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround cable shields at a single point on the enclosure system earth busbar to prevent ground loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178895049016,"sku":"ATI3S-001","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/322.2.jpg?v=1788766513"},{"product_id":"te32-yokogawa-centum-vp-terminal-block-module","title":"TE32 YOKOGAWA CENTUM VP Terminal Block Module","description":"\u003ch2\u003eYOKOGAWA TE32 Terminal Block Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-channel field signal termination in CENTUM VP and ProSafe-RS control architectures, the \u003cstrong\u003eYOKOGAWA TE32\u003c\/strong\u003e (\u003cstrong\u003eTE32\u003c\/strong\u003e Terminal Block) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTE32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP \/ ProSafe-RS terminal footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e32 termination points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP and ProSafe-RS I\/O systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe terminal block maintains individual physical conductor routing pathways that preserve channel-to-channel isolation specs established by connected analog and discrete I\/O modules. When routing 4-20 mA HART loop protocol signals through the 32 termination points, internal copper traces minimize impedance shifts and signal attenuation. This ensures clean HART digital FSK modulation overlay transmission across analog current loops without introducing crosstalk or signal degradation between adjacent processing channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TE32 terminal block require external power supply feeds for passive signal passthrough?\u003c\/p\u003e\n\u003cp\u003eA: No. The TE32 is a passive termination interface that routes analog and discrete field cabling directly to I\/O module connectors without consuming internal backplane or loop power.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module prevent wiring strain from damaging internal connector pins?\u003c\/p\u003e\n\u003cp\u003eA: Integrated mechanical cable anchor points and screw-down terminal clamps secure individual field wires, distributing physical tension away from internal backplane connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that field signal lines are de-energized before connecting wires to the terminal assembly. Align the terminal housing with the DIN-rail or rack interface slot and press until the locking tabs snap into place.\u003c\/p\u003e\n\u003cp\u003eFor signal conductor landing and cabinet wiring:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eStrip field wire insulation to 7 mm and insert solid or ferruled conductors directly into the screw-clamp terminal slots.\u003c\/li\u003e\n\u003cli\u003eTighten terminal screws to specified torque limits using an insulated screwdriver to maintain low-resistance contact and prevent thermal hot spots.\u003c\/li\u003e\n\u003cli\u003eKeep field signal lines, especially 4-20 mA HART loops, separated from high-voltage AC power cables in dedicated wiring ducts.\u003c\/li\u003e\n\u003cli\u003eFasten overall cable shield drain wires directly to the cabinet enclosure copper earth busbar using low-impedance ground clamps.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178906845496,"sku":"TE32","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/TE321.jpg?v=1759110117"},{"product_id":"yokogawa-tert-centum-vp-prosafe-rs-terminal-board","title":"YOKOGAWA TERT CENTUM VP ProSafe-RS Terminal Board","description":"\u003ch2\u003eYOKOGAWA TERT Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA TERT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTERT\u003c\/strong\u003e Terminal Board, operates as a dedicated hardware component for field signal termination and I\/O module interconnectivity within CENTUM VP and ProSafe-RS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTERT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP \/ ProSafe-RS terminal board footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation via system I\/O module coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003eDiscrete and 4-20 mA HART loop protocol pass-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Field Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe terminal board provides structured signal routing pathways that interface field instruments directly with control node I\/O modules while maintaining channel-to-channel isolation parameters established by the connected system cards. Internal circuit traces handle 4-20 mA HART loop protocol signal pass-through without introducing impedance attenuation or phase shift. This isolated termination architecture prevents ground potential shifts between field device junction boxes and backplane processing buses, maintaining clean signal transmission across DCS and SIS loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can field wiring connections be modified on the TERT terminal board while the system node is active? A: Field wiring can be landed or disconnected individually provided the associated field loop power is de-energized, as the passive board structure does not interrupt backplane bus operations.\u003c\/p\u003e\n\u003cp\u003eQ: How does the pass-through design support HART digital communication signals? A: Internal circuit pathing maintains constant loop impedance and minimal capacitive loading, allowing high-frequency HART digital frequency-shift keying (FSK) signals to pass transparently to analog input\/output cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal board securely on the cabinet DIN rail or rack assembly before terminating field wiring leads. Align the multi-pin system interface cable connector with the corresponding socket on the board, then tighten the retaining screws to ensure continuous ground continuity and signal contact.\u003c\/p\u003e\n\u003cp\u003eFor system wiring and cabinet commissioning:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eStrip field wire insulation to 7 mm and land leads into specified screw or spring-clamp terminals.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between analog 4-20 mA instrumentation cables and high-voltage AC power conductors within cabinet wire ducts.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shield drain wires directly at the cabinet main copper grounding busbar to prevent ground loop currents from entering the board.\u003c\/li\u003e\n\u003cli\u003eVerify torque settings on all screw terminals to eliminate loose contacts and preserve long-term signal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178949607736,"sku":"TERT","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/TERT2.jpg?v=1759110117"},{"product_id":"atsa3s-0-yokogawa-prosafe-rs-digital-output-terminal-block","title":"ATSA3S-0 Yokogawa ProSafe-RS Digital Output Terminal Block","description":"\u003ch2\u003eYokogawa ATSA3S-0 Digital Output Terminal Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for field signal termination and switching in ProSafe-RS safety systems, the \u003cstrong\u003eYokogawa ATSA3S-0\u003c\/strong\u003e (\u003cstrong\u003eATSA3S-0\u003c\/strong\u003e Digital Output Terminal Assembly) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATSA3S-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e60.5 mm x 32.6 mm x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Field Bus Powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e8 Points \/ 16 Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC channel-to-channel, 1500 VAC channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Rating\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Galvanic Protection\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ATSA3S-0 incorporates dedicated galvanic isolation barriers providing 250 VAC channel-to-channel and 1500 VAC channel-to-ground protection across all field connections. This hardware architecture eliminates common-mode ground loops and suppresses cross-talk noise during high-speed signal switching. Furthermore, the terminal assembly maintains signal integrity across 4-20 mA HART loops, supporting high-density field wiring without degrading analog resolution or digital diagnostic communication channels in safety instrumented functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ATSA3S-0 terminal assembly support online hot-swapping during safety system operation?\u003c\/p\u003e\n\u003cp\u003eA: Field technicians can replace the assembly unit online without de-energizing adjacent system modules, provided intrinsic safety parameters and field loop connections remain within certified tolerances.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation protect the system against field wiring faults?\u003c\/p\u003e\n\u003cp\u003eA: Individual galvanic barriers isolate high-voltage field surges up to 250 VAC on a single channel, preventing fault propagation to neighboring channels or internal backplane electronics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, verify that the cabinet power is isolated and confirm that the field environment complies with the ISA S71.04 Class G3 corrosive gas rating before opening the enclosure. Mount the terminal assembly on a standard DIN rail, ensuring secure mechanical grounding between the terminal chassis clip and the protective earth rail. Second, terminate field signal cables using color-coded wire ferrules, keeping high-voltage AC lines strictly segregated from 4-20 mA field instrument wiring to eliminate cross-talk interference. Finally, maintain a minimum bend radius on field cables and check all terminal screw torques to prevent intermittent connections under industrial vibration.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178963468600,"sku":"ATSA3S-0","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/338..jpg?v=1788835529"},{"product_id":"yokogawa-ec402-51-centum-vp-vnet-ip-bus-coupler-module","title":"Yokogawa EC402-51 CENTUM VP Vnet\/IP Bus Coupler Module","description":"\u003ch2\u003eYokogawa EC402-51 Bus Coupler Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa EC402-51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eEC402-51\u003c\/strong\u003e Bus Coupler Module, operates as a dedicated hardware component for high-speed data packet bridge execution between field control units and the Vnet\/IP real-time network across Yokogawa CENTUM VP DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEC402-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control Unit Chassis Slot Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP \/ ProSafe-RS Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (up to 5 A continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ45, Coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC input-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Noise\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 50 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa EC402-51 module incorporates internal high-frequency isolation barriers providing 1500 VAC protection between power rail inputs, backplane logic, and external network interfaces. By maintaining sub-50 mV peak-to-peak ripple noise limits on the output circuit, the bus coupler prevents high-frequency power spikes from introducing crosstalk into adjacent analog I\/O cards processing 4-20 mA HART loop signals. Dual physical interfaces (Ethernet and coaxial) support deterministic data conversion while isolating digital communication lines from ground potential differences across distributed field node locations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the EC402-51 bus coupler handle online backplane module replacement without interrupting Vnet\/IP network communications?\u003c\/p\u003e\n\u003cp\u003eA: The module bus interface circuitry supports hot-swapping within designated rack slots, allowing field engineers to pull or insert the unit without disrupting active Vnet\/IP token passing on the dual-redundant bus segment.\u003c\/p\u003e\n\u003cp\u003eQ: What protective measures exist within the module power management circuit to prevent downstream backplane damage?\u003c\/p\u003e\n\u003cp\u003eA: Integrated over-voltage, over-current, and thermal shutdown circuits monitor internal power distribution continuously, cutting power execution automatically if fault currents exceed safety thresholds.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, turn off primary rack AC power feeds before sliding the bus coupler module along cabinet guide rails, securing the top and bottom retaining screws to establish ground continuity with the backplane frame. Connect coaxial or RJ45 communication cables using high-flex industrial-grade shielded conductors, maintaining a minimum bend radius of 50 mm to avoid attenuation. Second, ground the cable shield braid directly to the cabinet protective earth (PE) busbar using low-impedance grounding clamps to prevent ambient electromagnetic interference. Finally, ensure surrounding cabinet space allows natural convection cooling to keep operating temperatures within the -10 to +60 deg C rating.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178977820984,"sku":"EC402-51","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/EC402-51.jpg?v=1759110117"},{"product_id":"anr10d-420-ndel-yokogawa-centum-vp-node-interface-module","title":"ANR10D-420\/NDEL Yokogawa CENTUM VP Node Interface Module","description":"\u003ch2\u003eYokogawa ANR10D-420\/NDEL Node Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANR10D-420\/NDEL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANR10D\u003c\/strong\u003e Node Interface Unit, operates as a dedicated hardware component for high-speed node communication execution within Yokogawa CENTUM CS 3000 and CENTUM VP DCS network architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANR10D-420\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DCS Node Chassis Rack Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000 \/ CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eVnet \/ Vnet\/IP Network Bus Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Connection\u003c\/td\u003e\n\u003ctd\u003eEthernet \/ Coaxial Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation \u0026amp; FOUNDATION Fieldbus Integration\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ANR10D-420\/NDEL provides galvanic isolation between internal backplane processing logic and external node network loops. This isolation barrier blocks high-voltage transients and prevents ground loops from propagating into sensitive field bus communications. By maintaining signal purity across 4-20 mA HART loops and FOUNDATION Fieldbus PA segments, the interface unit guarantees deterministic data transfer from field control units (FCUs) to distributed controller nodes without signal degradation or packet dropping.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What mechanisms prevent communication drops when replacing the ANR10D-420\/NDEL in a dual-redundant node layout?\u003c\/p\u003e\n\u003cp\u003eA: In redundant bus topologies, removing the primary node interface unit triggers immediate hardware failover to the secondary standby unit, maintaining continuous backplane data transfer without controller reset.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit process high-density field data across both coaxial and Ethernet interface connections?\u003c\/p\u003e\n\u003cp\u003eA: Internal controller circuits manage protocol conversion latencies and buffer incoming serial streams to maintain deterministic frame synchronization between legacy coaxial buses and high-speed Ethernet backplanes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, turn off primary power to the node chassis before sliding the module into its designated rack slot, ensuring the backplane bus connectors engage fully. Tighten all front-panel retaining screws to establish solid mechanical grounding against the cabinet frame. Second, connect coaxial or Ethernet network lines using shielded cables, maintaining a minimum bending radius to prevent conductor stress. Secure all outer cable shields directly to the cabinet protective earth (PE) grounding bar using low-impedance grounding clamps. Finally, verify that ambient cabinet airflow remains unobstructed to keep operating temperatures within the specified 0 to 50 deg C range.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178979918136,"sku":"ANR10D-420\/NDEL","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANB10D-421CU2NNDEL2.jpg?v=1759110117"},{"product_id":"yokogawa-s2bn1d-19030-centum-vp-vnet-ip-interface-module","title":"Yokogawa S2BN1D-19030 CENTUM VP Vnet\/IP Interface Module","description":"\u003ch2\u003eYokogawa S2BN1D-19030 Interface Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa S2BN1D-19030\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS2BN1D\u003c\/strong\u003e Interface Unit, operates as a dedicated hardware component for high-speed data frame exchange between field control units and Vnet\/IP control networks within Yokogawa CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS2BN1D-19030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control Unit Chassis Rack Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ ProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ45, Coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (up to 5 A continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC input-to-output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Noise\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 50 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa S2BN1D-19030 incorporates galvanic isolation barriers rated up to 1500 VAC to insulate internal processing circuits from high-voltage field spikes. By restricting output ripple noise below 50 mV peak-to-peak, the unit prevents electromagnetic cross-talk into adjacent analog input cards handling 4-20 mA HART signal communication loops. Dual physical interfaces (Ethernet and coaxial) support deterministic serial protocol conversion while maintaining strict channel separation across distributed node connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the S2BN1D-19030 handle live backplane hot-swapping during dual-redundant Vnet\/IP network operation?\u003c\/p\u003e\n\u003cp\u003eA: Integrated bus isolation switches isolate the unit power lines upon extraction, enabling technicians to pull or replace the module without causing voltage dips or interrupting token passing on the active redundant bus segment.\u003c\/p\u003e\n\u003cp\u003eQ: What protective measures prevent power circuit faults from damaging connected system backplane nodes?\u003c\/p\u003e\n\u003cp\u003eA: Over-voltage, over-current, and thermal shutdown circuits monitor internal power distribution continuously, cutting power execution automatically if fault currents exceed safety thresholds.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, turn off primary rack AC power feeds before sliding the interface module along cabinet guide rails, securing the retaining screws to establish ground continuity with the chassis. Connect coaxial or RJ45 communication cables using industrial-grade shielded conductors, maintaining a minimum bend radius of 50 mm to avoid signal attenuation. Second, ground the cable shield braid directly to the cabinet protective earth (PE) busbar using low-impedance grounding clamps to prevent ambient electromagnetic interference. Finally, ensure surrounding cabinet space allows natural convection cooling to keep operating temperatures within the specified 0 to 50 deg C range.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51179245371704,"sku":"S2BN1D-19030","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/S2BN1D-190301.jpg?v=1759128953"},{"product_id":"yokogawa-cp81b-c-cp81b-centum-vp-mother-pcb-board","title":"YOKOGAWA CP81B*C CP81B CENTUM VP Mother PCB Board","description":"\u003ch2\u003eYOKOGAWA CP81B*C Mother PCB Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP81B*C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP81B\u003c\/strong\u003e Mother PCB Board, operates as a dedicated hardware component for central backplane power distribution and bus routing within CENTUM VP and ProSafe-RS control systems. It provides physical card guidance and internal backplane signal trace connectivity for up to eight installed I\/O modules and processor units across the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP81B*C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP \/ ProSafe-RS backplane chassis layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive system backplane board (Power distribution loss dependent on module loading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e8 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, ProSafe-RS Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Backplane Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP81B*C\u003c\/strong\u003e backplane incorporates channel-to-channel isolation architecture across its printed circuit routing to eliminate ground loop currents and prevent differential cross-talk between high-speed serial bus lines. Heavy copper plane layers maintain uniform DC voltage potential across all 8 slots while isolating field-side transients from reaching adjacent processor units. Consequently, the backplane maintains signal integrity during simultaneous high-frequency I\/O scanning across dense industrial networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does removing or replacing a module in one slot disrupt backplane communication on adjacent slots?\u003c\/p\u003e\n\u003cp\u003eA: No, the board supports independent module slot isolation. However, technicians must strictly verify that power distribution loading remains balanced and follow Yokogawa live insertion rules to prevent voltage transients on the shared backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the motherboard maintain signal routing integrity across all 8 slots under industrial electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eA: Ground plane shielding layers built into the multi-layer PCB design attenuate high-frequency noise and channel-to-channel crosstalk across internal data paths.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cstrong\u003eYOKOGAWA CP81B*C\u003c\/strong\u003e securely inside the designated system cabinet enclosure using standard mounting hardware. Verify that cabinet grounding bars connect to the motherboard ground terminals via short, low-impedance copper straps to divert field-induced electrostatic discharges. Ensure all module retaining clips engage fully into slot connectors to preserve bus contact integrity. Keep external field wiring isolated from the internal backplane traces to reduce noise coupling.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51179256774968,"sku":"CP81B*C","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CP81BC2.jpg?v=1759128953"},{"product_id":"ps35-a-ps35-yokogawa-centum-power-supply-module","title":"PS35*A PS35 YOKOGAWA CENTUM Power Supply Module","description":"\u003ch2\u003eYOKOGAWA PS35*A Power Supply Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA PS35*A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePS35\u003c\/strong\u003e Power Supply Modules, operates as a dedicated hardware component for regulating and distributing regulated DC power across backplane buses within CENTUM DCS system racks. It converts primary supply input into dual output rails to drive internal logic circuitry and field interface components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePS35*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM system rack power slot form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM DCS Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Power Rail Regulation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA PS35*A\u003c\/strong\u003e power supply module incorporates galvanic isolation barriers between its primary input circuit, internal backplane logic outputs, and auxiliary field power rails. Consequently, this design prevents high-voltage supply transients and line noise from propagating into sensitive processor logic or downstream 4-20 mA HART loop protocol interfaces. Internal voltage regulator circuits continuously monitor load currents across both the 5 VDC logic bus and 24 VDC field output rails to ensure stable voltage stability during step-load changes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the PS35*A manage internal thermal dissipation during continuous full-load operation?\u003c\/p\u003e\n\u003cp\u003eA: Heat dissipation occurs passively through integral cooling fins on the module housing. Technicians must maintain unimpeded vertical ventilation paths above and below the rack slot to prevent thermal throttling.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are required when replacing a PS35*A unit in a redundant power configuration?\u003c\/p\u003e\n\u003cp\u003eA: Engineers must verify that the parallel power supply unit is fully operational and sharing the bus load before unseating the target module to prevent an ungraceful system shutdown.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cstrong\u003eYOKOGAWA PS35*A\u003c\/strong\u003e securely into the assigned power supply slot of the baseplate chassis, confirming that edge connectors sit flush against the backplane receiver. Connect primary AC or DC supply lines using approved wire gauges, keeping power conductors strictly isolated from low-voltage field communication wiring. Bond the cabinet chassis to a low-impedance safety ground terminal before applying primary power. Finally, ensure all module locking screws are torqued down completely to sustain physical connection under industrial vibration.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51179269685560,"sku":"PS35*A","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/PS35A2.jpg?v=1759128952"},{"product_id":"yokogawa-infbu200-s1o-centum-vp-bus-interface-module","title":"Yokogawa INFBU200-S1O CENTUM VP Bus Interface Module","description":"\u003ch2\u003eYokogawa INFBU200-S1O Bus Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eINFBU200-S1O\u003c\/strong\u003e is a compact, rack-mountable bus interface module designed for Yokogawa’s CENTUM VP distributed control system. It operates as a communication bridge between system control processors and field I\/O subsystems using the Vnet\/IP protocol over full-duplex gigabit Ethernet. The module supports star topology connections via switching hubs, enabling flexible system expansion, and includes hot-swapping capabilities and diagnostic LEDs to facilitate maintenance and troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eNetwork Architecture and Communication\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes the Vnet\/IP protocol to maintain stable and high-speed data exchange across the control network. By connecting through switching hubs in a star topology, it simplifies network configuration and supports modular growth without disrupting existing infrastructure. Full-duplex gigabit Ethernet performance ensures high throughput for demanding real-time industrial control environments.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and Installation\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial reliability, the \u003cstrong\u003eINFBU200-S1O\u003c\/strong\u003e supports hot-swapping to allow replacement without powering down the entire node, minimizing maintenance downtime. Built-in diagnostic LEDs provide immediate visual status feedback for quick identification of communication links and module health during operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINFBU200-S1O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex gigabit Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTopology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStar topology via switching hubs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-swapping, diagnostic LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack-mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocol does the INFBU200-S1O use? A: It utilizes the Vnet\/IP protocol over full-duplex gigabit Ethernet.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swapping? A: Yes, it supports hot-swapping to allow replacement during system operation with minimal downtime.\u003c\/p\u003e\n\u003cp\u003eQ: What maintenance aids are included on the module? A: It features onboard diagnostic LEDs for status monitoring and troubleshooting.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51314168594744,"sku":"NFBU200-S10","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFBU200-S10.jpg?v=1762334192"},{"product_id":"yokogawa-nfcp501-w15-stardom-fcn-controller-cpu-module","title":"Yokogawa NFCP501-W15 STARDOM FCN Controller CPU Module","description":"\u003ch2\u003eYokogawa NFCP501-W15 Field Control Node CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNFCP501-W15\u003c\/strong\u003e is a Field Control Node (FCN) CPU module designed for Yokogawa’s STARDOM autonomous controller series. Powered by an Intel Atom E3815 processor running at 1.46 GHz with 256 MB of main memory, it executes real-time control logic and data acquisition tasks. The module features dual gigabit Ethernet ports to support redundant or segmented network configurations and operates reliably across an extended temperature range of -20 deg C to +70 deg C.\u003c\/p\u003e\n\u003ch3\u003eProcessing and Control Logic\u003c\/h3\u003e\n\u003cp\u003eEquipped with an x86-based Intel Atom E3815 processor, the module executes control applications programmed under the IEC 61131-3 standard. It operates as an autonomous control engine, managing distributed I\/O modules and exchanging operational data with higher-level SCADA systems such as Yokogawa FAST\/TOOLS or VDS platforms for remote monitoring and diagnostics.\u003c\/p\u003e\n\u003ch3\u003eNetworking and Environmental Specifications\u003c\/h3\u003e\n\u003cp\u003eNetworking is provided via two gigabit Ethernet interfaces, allowing network segmentation or path redundancy to maintain communication availability. The \u003cstrong\u003eNFCP501-W15\u003c\/strong\u003e represents the basic CPU variant operating within an extended temperature envelope of -20 deg C to +70 deg C; it does not carry explosion-proof protection ratings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFCP501-W15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTARDOM FCN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E3815 (1.46 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Gigabit Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic type (Non-explosion proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What control system family uses the NFCP501-W15 CPU module? A: It is designed specifically for Yokogawa STARDOM FCN autonomous controller systems.\u003c\/p\u003e\n\u003cp\u003eQ: Does the NFCP501-W15 carry explosion-proof certification for hazardous areas? A: No, the W15 model code suffix indicates a basic CPU variant without explosion protection.\u003c\/p\u003e\n\u003cp\u003eQ: What programming standards are supported for control strategy development? A: The module supports IEC 61131-3 standard programming languages.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51314176098616,"sku":"NFCP501-W15","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFCP501-W15.jpg?v=1762334192"},{"product_id":"ls38-c3s-ti-n-gd-yokogawa-sfp-fiber-optic-transceiver-modules","title":"LS38-C3S-TI-N-GD Yokogawa SFP Fiber Optic Transceiver Modules","description":"\u003ch2\u003eYokogawa LS38-C3S-TI-N-GD SFP Fiber Optic Transceiver Module\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eLS38-C3S-TI-N-GD\u003c\/strong\u003e is a Small Form-Factor Pluggable (SFP) fiber optic transceiver module designed for high-speed communication links in industrial automation networks. Operating at a 1310 nm wavelength, it supports single-mode optical fiber transmission up to 10 kilometers at data rates ranging from 1.063 to 1.25 Gbps.\u003c\/p\u003e\n\u003ch3\u003eOptical Performance and Transmission\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates a Fabry-Perot (FP) laser diode transmitter and a PIN photodiode receiver, interfacing via a duplex LC optical connector. It delivers a transmitter output power between –9.5 and –3 dBm with an approximate link budget of 10.5 dB, ensuring reliable long-distance data exchange across distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eElectrical and Environmental Characteristics\u003c\/h3\u003e\n\u003cp\u003ePowered by a 3.3 VDC supply with a maximum current consumption of 250 mA, the unit supports hot-swappable installation and features built-in Digital Diagnostic Monitoring (DDM). It operates across an ambient temperature range of –40 deg C to +85 deg C for deployment in harsh industrial field enclosures.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLS38-C3S-TI-N-GD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFiber Optic Transceiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSFP (Small Form-Factor Pluggable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e1.063 to 1.25 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Wavelength\u003c\/td\u003e\n\u003ctd\u003e1310 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 10 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eSingle-Mode Fiber (9\/125 um SMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Connector\u003c\/td\u003e\n\u003ctd\u003eDuplex LC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eFabry-Perot (FP) laser diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN photodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Output Power\u003c\/td\u003e\n\u003ctd\u003e–9.5 to –3 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Pluggable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Monitoring\u003c\/td\u003e\n\u003ctd\u003eDDM (Digital Diagnostic Monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum transmission distance for the LS38-C3S-TI-N-GD module? A: It supports data transmission up to 10 kilometers over single-mode optical fiber (9\/125 um).\u003c\/p\u003e\n\u003cp\u003eQ: What type of optical connector does the transceiver use? A: It utilizes a duplex LC optical connector interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support real-time diagnostic monitoring? A: Yes, it is equipped with Digital Diagnostic Monitoring (DDM) capabilities.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51321484640568,"sku":"LS38-C3S-TI-N-GD","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/393.jpg?v=1793614881"},{"product_id":"nfbu050-s15-yokogawa-fcn-rtu-short-base-modules","title":"NFBU050-S15 Yokogawa FCN-RTU Short Base Modules","description":"\u003ch2\u003eYokogawa NFBU050-S15 Short Base Module\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eNFBU050-S15\u003c\/strong\u003e is a short base module designed to provide mechanical mounting and electrical backplane connectivity for CPU and I\/O modules. It is compatible with Yokogawa FCN-RTU low-power autonomous controllers and CENTUM VP distributed control systems, supporting up to three I\/O modules when paired with an NFCP050 CPU.\u003c\/p\u003e\n\u003ch3\u003eMounting and Environmental Specifications\u003c\/h3\u003e\n\u003cp\u003eThe compact chassis supports both DIN rail and 19-inch rack mounting options to accommodate space-constrained control panels. It operates across an ambient temperature range of –20 deg C to +70 deg C and is rated for installations at altitudes up to 3000 meters.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFBU050-S15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eShort Base Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eFCN-RTU, CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3 I\/O modules (with NFCP050 CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN rail, 19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 142.5 x 65.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which control systems are compatible with the NFBU050-S15 base module? A: It is designed for use with Yokogawa FCN-RTU and CENTUM VP control system architectures.\u003c\/p\u003e\n\u003cp\u003eQ: How many I\/O modules can be mounted on this base? A: It supports up to three I\/O modules when installed alongside an NFCP050 CPU.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting configurations are supported by the enclosure? A: The module can be mounted using either a standard DIN rail or a 19-inch equipment rack.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51321499877688,"sku":"NFBU050-S15","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFBU050-S151.jpg?v=1762504790"},{"product_id":"yokogawa-afs40d-h4113-afs40d-series-field-control-unit-fcu","title":"Yokogawa AFS40D-H4113 AFS40D Series Field Control Unit FCU","description":"\u003ch2\u003eYokogawa AFS40D-H4113 CENTUM CS 3000 Field Control Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AFS40D-H4113\u003c\/strong\u003e is a duplexed Field Control Unit (FCU) engineered for the CENTUM CS 3000 distributed control system. Powered by a 133 MHz VR5432 processor with 16 MB of main memory, it executes real-time control logic and coordinates Fieldbus Input\/Output (FIO) communications across industrial process automation networks.\u003c\/p\u003e\n\u003ch3\u003eRedundant Control and Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe unit incorporates a dual-redundant control architecture with redundant V-net network interfaces and ESB bus communication paths. This redundant framework ensures continuous high system availability and seamless failover execution during process control operations.\u003c\/p\u003e\n\u003ch3\u003ePower Configuration and System Integration\u003c\/h3\u003e\n\u003cp\u003eConfigured with a single 100–120 V AC power supply, the unit functions as a standard Field Control Station running under the LFS1300 software license. It is constructed for control cabinet mounting, measuring 207 mm × 265.9 mm × 482.6 mm and weighing 8 kg, with an operating temperature rating from -20 to +60 deg C.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAFS40D-H4113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplexed Field Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eAFS40D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e133 MHz VR5432\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDuplexed \/ Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eDual-redundant V-net, Dual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Subsystem\u003c\/td\u003e\n\u003ctd\u003eFieldbus Input\/Output (FIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 120 V AC (Single power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware License\u003c\/td\u003e\n\u003ctd\u003eLFS1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e207 mm × 265.9 mm × 482.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are integrated into the Yokogawa AFS40D-H4113? A: The module includes dual-redundant V-net interface ports for system communication and a dual-redundant ESB bus for field I\/O expansion.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply voltage does this Field Control Unit require? A: This specific configuration operates on a single 100–120 V AC power supply input.\u003c\/p\u003e\n\u003cp\u003eQ: Which software license corresponds to the control functionality of the AFS40D-H4113? A: The control unit runs standard station functionality under the LFS1300 software license.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51321549488440,"sku":"AFS40D-H4113","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/396.1.jpg?v=1793676723"},{"product_id":"ut320-30-yokogawa-ut320-green-series-controller","title":"UT320-30 Yokogawa UT320 Green Series Controller","description":"\u003ch2\u003eYokogawa UT320-30 UT320 Green Series Digital Indicating Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa UT320-30\u003c\/strong\u003e is a 1\/8 DIN digital indicating controller from Yokogawa's UT320 Green Series, designed for process variable monitoring and temperature control. Equipped with a universal input channel, it accepts thermocouples, RTDs, DC millivolts, and DC voltage signals. The unit features auto\/manual switching, PID control with SUPER and SUPER2 overshoot suppressing functions, and ON\/OFF control modes.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Output Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe front panel houses a 4-digit PV and 4-digit SP digital LED display with 12 mm characters for high visibility. Control outputs accommodate relay contacts, voltage pulse, or 4–20 mA DC signals. A 4–20 mA DC retransmission output and a standard 15 V DC loop power supply are integrated into the base unit, with an optional 24 V DC loop supply available for field transmitters.\u003c\/p\u003e\n\u003ch3\u003eEnclosure and Operating Specifications\u003c\/h3\u003e\n\u003cp\u003eConstructed for panel mounting, the housing measures 48 mm × 96 mm × 100 mm and weighs 1 kg or less. The front panel features an IP55 ingress protection rating. Power requirements range from 90 to 264 V AC with a maximum power consumption of 20 VA. The controller operates across temperatures of 0 to 50 deg C and humidity ranges from 20% to 90% RH non-condensing.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUT320-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Indicating Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eUT320 Green Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 universal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, DC mV, DC voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Modes\u003c\/td\u003e\n\u003ctd\u003eON\/OFF, PID (Auto-tuning, SUPER, SUPER2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e4-digit PV \/ 4-digit SP LED display (12 mm PV characters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output Types\u003c\/td\u003e\n\u003ctd\u003eRelay, Voltage Pulse, 4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Auxiliary Outputs\u003c\/td\u003e\n\u003ctd\u003eStandard retransmission output, Standard 15 V DC loop power supply (24 V DC optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Protection\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e48 mm × 96 mm × 100 mm (1\/8 DIN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e20% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the Yokogawa UT320-30 controller currently active or discontinued? A: The UT320 series has been discontinued by the manufacturer. Yokogawa recommends the UT35A or UT32A series models as direct replacements.\u003c\/p\u003e\n\u003cp\u003eQ: What auxiliary field power supply features are standard on the UT320-30? A: The unit comes standard with a retransmission output and an internal 15 V DC loop power supply to power auxiliary transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting size and panel protection rating does the UT320-30 feature? A: It features a standard 1\/8 DIN panel-mount form factor (48 mm × 96 mm × 100 mm) with an IP55 rated front panel\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51321605685560,"sku":"UT320-30","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UT320-302.jpg?v=1762504790"},{"product_id":"yokogawa-aip830-101-vesa-flat-panel-operation-keyboard-specs","title":"Yokogawa AIP830-101\/VESA Flat-Panel Operation Keyboard Specs","description":"\u003ch2\u003eYokogawa AIP830-101\/VESA Flat-Panel Operation Keyboard\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eAIP830-101\/VESA\u003c\/strong\u003e is a dedicated flat-panel operation keyboard engineered for Human Interface Stations within CENTUM VP and CENTUM CS 3000 distributed control systems. It provides operators with precise tactile control, alphanumeric data entry, and integrated audio notifications for single-loop industrial processes.\u003c\/p\u003e\n\u003ch3\u003eFunctional Design and Layout\u003c\/h3\u003e\n\u003cp\u003eThe keyboard features an integrated layout comprising alphanumeric keys, dedicated operation keys, and up to 64 user-defined function keys. These controls enable rapid execution of process commands, mode selections, and alarm acknowledgments directly from the control console.\u003c\/p\u003e\n\u003ch3\u003eSystem Integration and Connectivity\u003c\/h3\u003e\n\u003cp\u003eCommunication and power are established via dual USB Type-A connectors, delivering USB 2.0 full-speed keyboard data and USB 1.1 audio signals. Both interface cables must connect directly to the host computer to ensure reliable bus-powered operation without external power supplies.\u003c\/p\u003e\n\u003ch3\u003eMechanical and Environmental Specifications\u003c\/h3\u003e\n\u003cp\u003eDesigned for console or desktop integration, the unit supports VESA mounting brackets for flexible positioning. The robust chassis operates reliably within controlled industrial environments adhering to IEC 61010-1 Class I standards.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eAIP830-101\/VESA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlat-Panel Operation Keyboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eAIP830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Configuration\u003c\/td\u003e\n\u003ctd\u003eAlphanumeric, Dedicated Operation, 64 User-Defined Function Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudio Function\u003c\/td\u003e\n\u003ctd\u003eIntegrated USB Speaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003e2 × USB Type-A Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eVESA Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e500 × 225 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (with VESA bracket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e5 deg C to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e20% to 80% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which control systems are compatible with this keyboard? A: It is designed for Yokogawa CENTUM VP and CENTUM CS 3000 Human Interface Stations.\u003c\/p\u003e\n\u003cp\u003eQ: How is the unit powered during operation? A: It is powered entirely via the USB bus, drawing a maximum current of 1 A from the host system.\u003c\/p\u003e\n\u003cp\u003eQ: Are both USB connectors required for connection? A: Yes, both USB Type-A cables must be connected directly to the computer to support keyboard functions and the integrated speaker.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51333494538552,"sku":"AIP830-101\/VESA","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIP830-101VESA.jpg?v=1762853999"},{"product_id":"ynt511d-p42-yokogawa-centum-vp-optical-bus-repeater-modules","title":"YNT511D-P42 Yokogawa CENTUM VP Optical Bus Repeater Modules","description":"\u003ch2\u003eYokogawa YNT511D-P42 Optical Bus Repeater Module\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eYNT511D-P42\u003c\/strong\u003e is an optical bus repeater designed to extend communication distances across V net and RIO bus networks within CENTUM VP and CENTUM CS distributed control systems. By converting electrical coaxial signals into optical signals and back, it enables reliable long-distance data transmission while insulating control loops from severe electrical noise and electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eBus Signal Conversion and Optical Links\u003c\/h3\u003e\n\u003cp\u003eThe module bridges a 10BASE-2 coaxial electrical bus with multimode glass fiber cables using standard SC optical connectors. Operating at an optical wavelength of 1,300 nm, it supports a maximum optical loss budget of 6.0 dB and accommodates fiber core\/cladding dimensions of 50\/125 μm with a numerical aperture of 0.20 to 0.22.\u003c\/p\u003e\n\u003ch3\u003eSystem Network Expansion\u003c\/h3\u003e\n\u003cp\u003eEngineered for dual-redundant communication architectures, a pair of repeaters provides a maximum transmission distance of up to 4 km between remote control cabinets, operator stations, and remote I\/O racks. The unit installs into standard industrial racks within control cabinets to maintain high availability across distributed plant facilities.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eYNT511D-P42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOptical Bus Repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eYokogawa V net, RIO Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Interface\u003c\/td\u003e\n\u003ctd\u003e10BASE-2 Coaxial Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Connector\u003c\/td\u003e\n\u003ctd\u003eSC Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003e50\/125 μm Multimode Glass Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Wavelength\u003c\/td\u003e\n\u003ctd\u003e1,300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 4 km per repeater pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Optical Loss\u003c\/td\u003e\n\u003ctd\u003e6.0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumerical Aperture\u003c\/td\u003e\n\u003ctd\u003e0.20 to 0.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-Redundant Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e328 mm × 130 mm × 258 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What communication networks does the YNT511D-P42 repeater support? A: It is designed for Yokogawa V net and RIO bus networks used in CENTUM VP and CENTUM CS control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What type of fiber optic cabling is required for installation? A: The module requires 50\/125 μm multimode glass fiber cable terminated with SC type optical connectors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum distance achievable between two stations using this repeater? A: A pair of YNT511D-P42 repeaters can transmit data across optical fiber links up to 4 km apart, provided total optical attenuation remains within the 6.0 dB loss budget.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51333496668472,"sku":"YNT511D-P42","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/YNT511D-P42.jpg?v=1762853999"},{"product_id":"aip821-yokogawa-centum-vp-industrial-operation-keyboards","title":"AIP821 Yokogawa CENTUM VP Industrial Operation Keyboards","description":"\u003ch2\u003eYokogawa AIP821 Industrial Flat-Panel Operation Keyboard\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eAIP821\u003c\/strong\u003e is an industrial flat-panel operation keyboard built for operator stations in process automation systems. Designed for integration with Yokogawa CENTUM VP and CENTUM CS 3000 Human Interface Stations (HIS), it provides dedicated physical controls for process navigation, loop adjustment, and system alarm acknowledgment.\u003c\/p\u003e\n\u003ch3\u003eKeyboard Layout and System Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AIP821 features an ergonomic key configuration combining standard alphanumeric keys with dedicated operation keys to streamline routine control room tasks. Communication and bus-powered operation are handled via two USB Type-A connectors, delivering USB 2.0 full-speed keyboard data transmission alongside a USB 1.1 interface for integrated audio functionality.\u003c\/p\u003e\n\u003ch3\u003eAudio Integration and Console Installation\u003c\/h3\u003e\n\u003cp\u003eAn integrated speaker receives system alerts directly over the USB interface, eliminating external speaker cabling. The compact flat-panel chassis supports both desktop positioning and operator console mounting, operating reliably on standard 5 V DC bus power without requiring an external power supply.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eAIP821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Operation Keyboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Configuration\u003c\/td\u003e\n\u003ctd\u003eAlphanumeric Keys, Dedicated Operation Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003e2 × USB Type-A Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard Interface\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Full-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudio Interface\u003c\/td\u003e\n\u003ctd\u003eUSB 1.1 (Integrated Speaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eUSB Bus-Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e500 × 225 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg to 2.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What systems are compatible with the AIP821 keyboard? A: It is designed for Yokogawa Human Interface Stations, including CENTUM VP and CENTUM CS 3000 DCS platforms.\u003c\/p\u003e\n\u003cp\u003eQ: How is the AIP821 keyboard powered? A: It operates directly on 5 V DC USB bus power from the host system, drawing a maximum current of 1 A.\u003c\/p\u003e\n\u003cp\u003eQ: Does the AIP821 require an external audio connection for system alarms? A: No, it receives audio alert signals directly via its built-in USB 1.1 audio interface to drive the integrated speaker.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51333496930616,"sku":"AIP821","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/486.jpg?v=1793945967"},{"product_id":"disconnecting-n-io-base-plate-yokogawa-s2bn1d-11130-prosafe-rs","title":"Disconnecting N-IO Base Plate | Yokogawa S2BN1D-11130 ProSafe-RS","description":"\u003ch2\u003eYokogawa S2BN1D-11130 ProSafe-RS N-IO Base Plate\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa S2BN1D-11130\u003c\/strong\u003e is a 16-channel N-IO Base Plate with disconnecting terminals engineered for the Yokogawa ProSafe-RS safety instrumented system (part of system model \u003cstrong\u003eS2ZN1D\u003c\/strong\u003e). It provides the physical mounting platform and electrical interface for N-IO modules, integrating field signal pressure clamp terminals, F-SB bus communication, and 24 VDC field power distribution for single or dual-redundant safety configurations.\u003c\/p\u003e\n\u003ch3\u003eField Wiring and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe base plate consolidates field connections while incorporating hardware isolation features for maintenance tasks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnecting Terminals:\u003c\/strong\u003e Integrated disconnecting terminals allow individual I\/O channels to be electrically isolated from field wiring during loop testing, troubleshooting, or module replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal and Power Interface:\u003c\/strong\u003e Connects 16 field signal channels via pressure clamp terminals and distributes 24 VDC field power at currents up to 11 A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Bus and Redundancy Architecture\u003c\/h3\u003e\n\u003cp\u003eDesigned to support high-availability safety instrumented loops, the \u003cstrong\u003eS2BN1D-11130\u003c\/strong\u003e interfaces directly with ProSafe-RS system components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Operation:\u003c\/strong\u003e Supports both single and dual-redundant N-IO module configurations on a single base plate assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus and Power Connections:\u003c\/strong\u003e Links to the F-SB communication bus using \u003cstrong\u003eS2KLF10\u003c\/strong\u003e bus cables and receives power distribution via \u003cstrong\u003eS2KPB10\u003c\/strong\u003e power supply cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Supports standard DIN rail or wall mounting within industrial control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS2BN1D-11130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Model\u003c\/td\u003e\n\u003ctd\u003eS2ZN1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eN-IO Base Plate with Disconnecting Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle \/ Dual Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Signal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure Clamp Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Bus\u003c\/td\u003e\n\u003ctd\u003eF-SB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Connection\u003c\/td\u003e\n\u003ctd\u003eS2KLF10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003eS2KPB10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Current\u003c\/td\u003e\n\u003ctd\u003eUp to 11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail \/ Wall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the function of the disconnecting terminals on the S2BN1D-11130? A: The integrated disconnecting terminals allow maintenance personnel to isolate individual I\/O channels from external field wiring without disconnecting the wires, simplifying loop checks and module replacement.\u003c\/p\u003e\n\u003cp\u003eQ: Does the S2BN1D-11130 support redundant I\/O modules? A: Yes, the base plate accommodates both single and dual-redundant N-IO module configurations across its 16 channels.\u003c\/p\u003e\n\u003cp\u003eQ: Which cables are used for bus and power connections on this base plate? A: The \u003cstrong\u003eS2BN1D-11130\u003c\/strong\u003e connects to the F-SB bus via \u003cstrong\u003eS2KLF10\u003c\/strong\u003e cables and uses \u003cstrong\u003eS2KPB10\u003c\/strong\u003e cables for power supply connections.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51344003006776,"sku":"S2BN1D-11130","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/S2BN1D-111302.jpg?v=1763016147"},{"product_id":"yokogawa-um210c10aa-2san-01s0668-servo-actuator","title":"Yokogawa UM210C10AA-2SAN\/01S0668 Servo Actuator","description":"\u003ch2\u003eYokogawa UM210C10AA-2SAN\/01S0668 Industrial Servo Actuator\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa UM210C10AA-2SAN\/01S0668\u003c\/strong\u003e is an industrial servo actuator engineered for precision motion control and automated machinery. It provides controlled actuation and positioning to support repeatable mechanical movement within industrial automation and servo control systems.\u003c\/p\u003e\n\u003ch3\u003eActuation and Mechanical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe unit is built for stable integration into automated equipment, combining compact physical dimensions with specified environmental tolerances:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Function:\u003c\/strong\u003e Delivers precision actuation and positioning for servo-driven industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e Measures approximately 32 x 148 x 200 mm with an overall weight of 3.1 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Ratings:\u003c\/strong\u003e Operates within a temperature range of -10 deg C to +60 deg C and handles relative humidity levels from 10% to 90% RH (non-condensing).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUM210C10AA-2SAN (Full Part Number: UM210C10AA-2SAN\/01S0668)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eServo Actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eIndustrial Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eServo Motion Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Function\u003c\/td\u003e\n\u003ctd\u003ePrecision Actuation and Positioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10%-90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32 x 148 x 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Origin\u003c\/td\u003e\n\u003ctd\u003eJapan (supplier-listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the UM210C10AA-2SAN\/01S0668? A: It functions as an industrial servo actuator designed to deliver precision actuation and positioning in motion control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical dimensions and weight of this unit? A: The actuator measures approximately 32 x 148 x 200 mm and weighs approximately 3.1 kg.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental conditions is the servo actuator rated for? A: It is rated to operate between -10 deg C and +60 deg C with a non-condensing operating humidity range of 10% to 90% RH.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51344023257400,"sku":"UM210C10AA-2SAN\/01S0668","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UM210C10AA-2SAN01S0668_94b0c73f-3439-4f67-a99b-3b8b8642537f.jpg?v=1763016147"},{"product_id":"16-point-m4-screw-terminal-block-yokogawa-te16","title":"16-Point M4 Screw Terminal Block | Yokogawa TE16","description":"\u003ch2\u003eYokogawa TE16 General-Purpose Terminal Block\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa TE16\u003c\/strong\u003e (also identified by style code \u003cstrong\u003eTE16*B\u003c\/strong\u003e) is a general-purpose 16-point terminal block designed for Yokogawa process automation and control systems. It provides a structured electrical interface between field instrumentation wiring and compatible I\/O modules using M4 screw terminals, supporting non-incendive instrumentation applications via a KS2 connecting cable.\u003c\/p\u003e\n\u003ch3\u003eWiring and Electrical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe terminal block consolidates 16 discrete or analog field signal connections into a single termination strip for cabinet installation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Interface:\u003c\/strong\u003e Equipped with 16 M4 screw terminals for terminating field input wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e Rated for a withstanding voltage of 500 VAC and an insulation resistance of at least 100 MOhms at 500 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental and Safety Ratings:\u003c\/strong\u003e Operates within 0 to 50 deg C and 5% to 90% relative humidity, carrying CSA Non-Incendive certification for hazardous area instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTE16\u003c\/strong\u003e connects directly to the front or system interface of supported Yokogawa I\/O modules using a \u003cstrong\u003eKS2\u003c\/strong\u003e signal cable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible I\/O Modules:\u003c\/strong\u003e ADM1C, AMM12C, AMM22C, and ADV59 series modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTE16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStyle Code\u003c\/td\u003e\n\u003ctd\u003eTE16*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa (Yokogawa Electric Corporation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGeneral-Purpose Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM4 Screw Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eADM1C, AMM12C, AMM22C, ADV59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnecting Cable\u003c\/td\u003e\n\u003ctd\u003eKS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 100 MOhms (500 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Standard\u003c\/td\u003e\n\u003ctd\u003eCSA Non-Incendive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which Yokogawa I\/O modules are compatible with the TE16 terminal block? A: The \u003cstrong\u003eTE16\u003c\/strong\u003e is compatible with ADM1C, AMM12C, AMM22C, and ADV59 series I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What cable is required to connect the TE16 to an I\/O module? A: It connects to compatible Yokogawa I\/O modules using a \u003cstrong\u003eKS2\u003c\/strong\u003e connecting cable.\u003c\/p\u003e\n\u003cp\u003eQ: What type of wire terminals and environmental ratings does this unit have? A: It features 16 M4 screw terminals, operates from 0 to 50 deg C, and meets CSA Non-Incendive standards.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51344029483320,"sku":"TE16","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/TE16.jpg?v=1763016146"},{"product_id":"yokogawa-snb10d-225-cu2t-prosafe-rs-safety-node-unit-rack","title":"Yokogawa SNB10D-225\/CU2T ProSafe-RS Safety Node Unit Rack","description":"\u003ch2\u003eYokogawa SNB10D-225\/CU2T ProSafe-RS Safety Node Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SNB10D-225\/CU2T\u003c\/strong\u003e is a rack-mountable Safety Node Unit designed for the Yokogawa ProSafe-RS Safety Instrumented System (SIS). It interfaces field input and output modules with the safety control architecture via the Enhanced System Bus (ESB), supporting up to eight I\/O modules in safety-critical process applications.\u003c\/p\u003e\n\u003ch3\u003ePower and Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe unit integrates reliable power distribution and network communication components for fault-tolerant system setups:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Features a dual-redundant power supply configuration operating at a rated input voltage of 220 to 240 VAC (50\/60 Hz) with an approximate power consumption of 230 VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESB Bus Interface:\u003c\/strong\u003e Equipped with dual SSB401 interfaces and an ESB bus terminator, utilizing a CU2T connector unit (connector part number S9343FA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Capacity:\u003c\/strong\u003e Accommodates the installation of up to eight safety I\/O modules on its 19-inch rack-mountable chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental and Mechanical Specifications\u003c\/h3\u003e\n\u003cp\u003eEngineered for demanding industrial facilities, the node unit meets stringent environmental and mounting standards:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Range:\u003c\/strong\u003e Rated for an operating temperature range of -20 to +70 deg C and complies with ISA Standard G3 environmental requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e Designed for 19-inch rack mounting using M5 screws and insulating bushes, with an approximate weight of 5.9 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 230 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Bus Interface\u003c\/td\u003e\n\u003ctd\u003eSSB401 x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Unit\u003c\/td\u003e\n\u003ctd\u003eCU2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Part Number\u003c\/td\u003e\n\u003ctd\u003eS9343FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Termination\u003c\/td\u003e\n\u003ctd\u003eESB Bus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Standard\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNot included in this configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003eM5 screws and insulating bushes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the SNB10D-225\/CU2T unit? A: It serves as a Safety Node Unit in the ProSafe-RS safety instrumented system, interfacing field I\/O modules with the safety control unit via the ESB bus.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply and voltage does this node unit require? A: It features a dual-redundant power configuration with a rated input voltage of 220 to 240 VAC at 50\/60 Hz and consumes approximately 230 VA.\u003c\/p\u003e\n\u003cp\u003eQ: How many I\/O modules can be installed on this safety node unit? A: The unit supports the installation of up to eight safety I\/O modules within its 19-inch rack-mounted chassis.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51344049832248,"sku":"SNB10D-225\/CU2T","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SNB10D-225CU2T.jpg?v=1763019032"},{"product_id":"yokogawa-nfcp502-w05-s1-stardom-fcn-500-cpu-module","title":"Yokogawa NFCP502-W05 S1 STARDOM FCN-500 CPU Module","description":"\u003ch2\u003eYokogawa NFCP502-W05 S1 STARDOM FCN-500 CPU Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP502-W05 S1\u003c\/strong\u003e is a central processing unit (CPU) module for the Yokogawa STARDOM FCN-500 autonomous controller system. Built around a 1.46 GHz Intel Atom E3815 processor with ECC-protected memory, it executes real-time control logic, manages SB Bus I\/O communications, and supports redundant controller configurations with extended software functions.\u003c\/p\u003e\n\u003ch3\u003eProcessing Architecture and Memory\u003c\/h3\u003e\n\u003cp\u003eThe module integrates enterprise-grade memory protection and non-volatile storage to maintain program integrity during power cycles and continuous operation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor and Main Memory:\u003c\/strong\u003e Powered by an Intel Atom E3815 CPU running at 1.46 GHz paired with 256 MB of ECC-protected main memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetentive and Flash Storage:\u003c\/strong\u003e Includes 2 MB of battery-backed ECC static RAM for data retention, 1 GB of onboard flash memory, and an external SDHC slot supporting 4 to 32 GB Class 10 cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Diagnostics:\u003c\/strong\u003e Features hardware watchdog timers, internal temperature monitoring, status LEDs (CPU, Ethernet, SD, EXEC), and physical control switches (RESET, SHUT DOWN, FUNC, EXEC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication and I\/O Interfaces\u003c\/h3\u003e\n\u003cp\u003eMultiple integrated network and bus interfaces connect the controller to supervisory networks, field devices, and local I\/O racks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e Equipped with four RJ45 ports supporting 10\/100\/1000 Mbps transmission speeds for control network and SCADA integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial and Bus Interfaces:\u003c\/strong\u003e Provides one RS-232-C serial port (9-pin male D-sub, 0.3 to 115.2 kbps) and an SB Bus interface for connecting local I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP502-W05 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa (Yokogawa Electric Corporation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSTARDOM FCN-500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCPU Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eAutonomous Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Atom E3815 (1.46 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e256 MB ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic RAM\u003c\/td\u003e\n\u003ctd\u003e2 MB ECC, battery-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Flash Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Storage\u003c\/td\u003e\n\u003ctd\u003e1 x SDHC card slot (4-32 GB, Class 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e4 x RJ45 (10\/100\/1000 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232-C (9-pin D-sub male, 0.3-115.2 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Interface\u003c\/td\u003e\n\u003ctd\u003eSB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Functions\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eWatchdog timer, temperature monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eCPU, Ethernet, SD, and EXEC LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Switches\u003c\/td\u003e\n\u003ctd\u003eRESET, SHUT DOWN, FUNC, and EXEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e1700 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-55 deg C (standard type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which controller platform is the NFCP502-W05 S1 designed for? A: It is built specifically for the Yokogawa STARDOM FCN-500 autonomous controller platform and connects to I\/O modules via the SB Bus interface.\u003c\/p\u003e\n\u003cp\u003eQ: What memory and external storage options are included on this CPU module? A: The unit provides 256 MB of ECC main memory, 2 MB of battery-backed ECC SRAM, 1 GB of onboard flash memory, and one SDHC slot compatible with 4 to 32 GB Class 10 cards.\u003c\/p\u003e\n\u003cp\u003eQ: Does the NFCP502-W05 S1 support redundant controller setups? A: Yes, the module supports redundant configurations and extended functions for continuous process control applications.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51374238236984,"sku":"NFCP502-W05 S1","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFCP502-W05_S1.jpg?v=1763520054"}],"url":"https:\/\/www.automodulexpert.com\/collections\/yokogawa-power-supply-module.oembed?page=3","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}