Overview
The MMS 6410 is a Dual Channel Measuring Amplifier for inductive displacement sensors, designed for precise measurements in various industrial applications.
Technical Specifications
-
Sensor Inputs:
- Two independent inputs for inductive sensors in half- or full bridge configuration and for differential transformers.
- The signal inputs are differential inputs, galvanically isolated from the system supply, open circuit and short circuit proof.
-
Max. Input Voltage:
- 3.6 V (protected against over voltages)
-
Nominal Input Voltage Range:
- 2.5 V rms
-
Input Impedance:
- 200 kOhm
-
Measuring Ranges:
- Measuring frequency range: 0....100 Hz -3dB
- Measuring range displacement measurement: Depending on transducer measuring range; one or both outputs may be inverted.
-
Sensor Supply:
- Each input includes a separate, buffered output to supply inductive sensors.
- Carrier Frequency: 4.75 kHz
- Nominal Supply Voltage: 4 Vrms
- Permissible Load: 120....600 Ohm
- The outputs are balanced to ground, open-circuit and short-circuit proof.
-
Control Inputs:
- Common logical binary inputs for the two channels.
-
Optocoupler Mode:
- "Pre-alarm (ALERT)", open circuit or closed circuit mode
- "Main alarm (DANGER)", open circuit or closed circuit mode
- Channel or module inhibit
- Limit value multiplier for changing alarm limits during run-up and run-down of the machine, adjustable in the range: 1.000....4.999
- 24 V Logic
- Input Resistance: > 10 kOhm
-
Key Pulse Input:
- 1 pulse per revolution for analysis purposes of the system.
- 24 V Logic
- Input Resistance: > 30 kOhm
- Pulse Duration: min. 10 µs (edge-triggered)
Signal Outputs at the Connecting Strip
- Connecting Strip: according to type F48M, DIN41612
- Communication Interface: RS485
-
Outputs:
-
Current Output per Channel:
- Nominal range: 0/4...20 mA
- Open circuit and short-circuit proof
- Permissible Burden: ≤500 Ohm
- Resolution: 16 Bit
- Accuracy: ±1% of f.s.d.
-
Voltage Output per Channel:
- Nominal range: 0...+10 V
- Open circuit and short-circuit proof
- Load Resistance: ≥10 kOhm
- Resolution: 8 Bit
- Accuracy: ±1 % of f.s.d
-
Voltage Output per Channel (Sensor Signal):
- Nominal range: 0...12 Vpp
- Open circuit and short-circuit proof
- Load Resistance: ≥100 kOhm
- Frequency Range: 0 Hz...20 kHz (±20 % -3 dB)
- Accuracy: ±1 % of f.s.d
-
Current Output per Channel:
Operating Elements at the Module Front
- Two sensor signal outputs, independently from each other, one for each channel.
- The signals are proportional to the sensor signals and can be tapped at the SMB sockets on the module front.
- Range: ±12 V
- Load Resistance: 100 kOhm
- Internal Resistance: 1 kOhm
- Frequency Range: Dynamic carrier frequency output with superimposed displacement signal.
-
LED Indicators:
- 2 green LEDs for "Channel Clear" separately for channel 1 and channel 2.
- 4 red LEDs for pre and main alarm separately for both channels.
- Mini DIN Diode Socket: RS232 interface for connection of a computer for configuration and data interchange with the module.
- Handle: To pull out and insert the module and for labeling purposes.
Power Supply
- System Design: Redundant supply input via two supply inputs, decoupled via diodes. At least one supply input is required for the supply of the module.
- Supply Voltage: 18....24....31.2 V DC according to IEC 654-2, class DC4
- Power Consumption: max. 8 W (max. 300 mA at 24 V)
- Other supply voltages can be realized with additional system power supplies.
- At standalone operation, an unlimited number of modules.
- Max. 31 modules / 62 channels may be operated at one RS 485 bus.
- If more modules / channels are necessary, e.g. with an MMS 6815, another RS 485 bus must be installed.
Environmental Conditions
-
Protection Class:
- Module: IP 00 according to DIN 40050
- Front Plate: IP21 according to DIN 40050
- Climate Conditions: according to DIN 40040 class KTF
- Operating Temperature Range: 0....+65°C
- Temperature Range for Storage and Transport: -30....+85°C
- Permissible Relative Humidity: 5....95%, non-condensing
-
Permissible Vibration: according to IEC 68-2, part 6
- Vibration Amplitude: 0.15 mm in range 10...55 Hz
- Vibration Acceleration: 16.6 m/s² in range 55...150 Hz
-
Permissible Shock: according to IEC 68-2, part 29
- Peak Value of Acceleration: 98 m/s²
- Nominal Shock Duration: 16 ms
- EMC Resistance: according to EN50081-1 / EN50082-2
Dimensions
- PCB/EURO Card Format: acc. to DIN 41494 (100 x 160 mm)
- Width: 30.0 mm (6 TE)
- Height: 128.4 mm (3 HE)
- Length: 160.0 mm
- Net Weight: approx. 320 g
- Space Requirements: 14 modules (28 channels) fit into each 19“ rack
| Schnelle Angebote | Erhalten Sie Preis & Verfügbarkeit SCHNELL von unserem engagierten Kundenserviceteam. |
|---|---|
| Lieferung | Schnellversand, Fracht- und internationaler Versand verfügbar. |
| Bedingung | 100% Neu mit Originalverpackung |
| Zahlung | Wir akzeptieren American Express, Discover, MasterCard, PayPal und Visa. Unsere Seite ist durch RapidSSL gesichert. |
| Versandhafen | Shanghai, Xiamen |
| Garantie | 12 Monate |
| Q: Sind unsere Preise wettbewerbsfähig? |
| A: Ja, wir arbeiten mit über 50 Ländern weltweit zusammen. Als führender Lieferant in China bieten wir basierend auf den Markttrends erhebliche Rabatte an. |
| Q: Wie lange ist die Garantiezeit? |
| A: Alle unsere neuen und originalen Produkte haben eine standardmäßige einjährige Garantie. |
| Q: Welche Zahlungsmethoden akzeptieren wir? |
| A: Wir verlangen 100 % T/T (Telegraphische Überweisung) vor dem Versand. Bei Artikeln mit längerer Lieferzeit ist eine Anzahlung von 30 % im Voraus erforderlich, der Rest von 70 % ist vor dem Versand fällig. Wenn Sie einen Vertreter in China haben, können Sie die RMB-Überweisung über ihn arrangieren. |
| Q: Welche Versandmethoden verwenden wir? |
| A: Wir verwenden hauptsächlich FedEx, DHL, UPS und BRE für den Versand. Wenn Sie ein Konto bei einem dieser Anbieter haben, können Sie den Versand direkt abwickeln. Wir bieten auch kostenlosen Versand an in China ansässige Spediteure. |
| Q: Wie lange ist unsere Lieferzeit? |
| A: Die Lieferung erfolgt in der Regel 1-3 Tage nach Erhalt der Anzahlung. Bei Artikeln mit längerer Lieferzeit erfolgt der Versand gemäß dem angegebenen Zeitplan. |
| Q: Wie verpacken wir die Waren? |
| A: Wir sorgen für sichere Verpackung mit mehreren Schutzschichten. Die Produkte werden zuerst in ihre Originalverpackungen gelegt und mit Etiketten versiegelt. Anschließend wird eine Schicht Luftpolsterfolie zum Schutz vor Stößen während des Transports hinzugefügt. Schließlich werden die Artikel sicher in robusten Kartons verpackt. |
| Q: Wie können Kunden uns kontaktieren und ein Angebot anfordern? |
| A: Sie können uns per E-Mail, WhatsApp, WeChat, Skype oder Ihrer bevorzugten Kommunikationsplattform erreichen. Kontaktieren Sie uns mit Ihren Anforderungen, und wir erstellen Ihnen ein schnelles, maßgeschneidertes Angebot. |
Kürzlich angesehen
Expressversand
Schnelle Lieferung für Ihre dringenden Anforderungen.
Umfangreiches Inventar
Großer Lagerbestand für sofortigen Versand.
Qualitätssicherung
Authentische, hochwertige PLC- und DCS-Komponenten.
Globaler Service
Unterstützung von Kunden weltweit mit zuverlässigem Service.