{"product_id":"mark-vi-is200exhsg3aec-high-speed-protection-board","title":"Mark VI IS200EXHSG3AEC High-Speed Protection Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200EXHSG3AEC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the High-Speed (HS) Relay Driver Board within the EX2100 Excitation Control System. This critical component integrates directly with the Mark VI turbine control platform to manage rapid switching operations for generator excitation and protection circuits. It drives the specific relays required for field flashing, rapid de-excitation, and immediate fault isolation. We supply this board as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the deterministic performance required to maintain generator stability in gas, steam, and hydroelectric power plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200EXHSG3AEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Speed Relay Driver Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEX2100 Excitation \/ Mark VI Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eActuation Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMillisecond-level (Deterministic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–30°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated feedback for relay status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack-mounted modular design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 kg (1.54 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExcitation Control and Protection Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Fault Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200EXHSG3AEC executes relay actuation within milliseconds. During a generator fault or emergency trip, the board triggers isolation relays instantly to clear field energy, preventing catastrophic damage to the excitation transformer and rotor windings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Protection Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board maintains rigid timing for field flashing and de-excitation sequences. By ensuring high-speed, deterministic switching, it optimizes generator synchronization and enhances the overall safety of the power protection scheme.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Mark VI Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned specifically for the EX2100 architecture, the board communicates directly with other control and protection modules in the rack. This hardware-level synergy allows the turbine control system to receive real-time diagnostic feedback on relay health and position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust circuitry operates reliably across a wide temperature spectrum (–30°C to +65°C). This durability ensures consistent relay driving even in the intense thermal environments typical of excitation cabinets and turbine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200EXHSG3AEC be used for retrofitting legacy systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This board remains fully compatible with existing EX2100 and Mark VI control architectures, making it an ideal choice for system upgrades or the replacement of aging hardware in legacy power plant infrastructures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this board handle relay failure diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200EXHSG3AEC includes integrated diagnostic feedback loops. The system monitors the continuity and actuation state of the driven relays, alerting the control station via the HMI if a relay fails to respond, enabling predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs any specialized software required for configuration after replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the board is a modular hardware replacement, you should verify and sync the board within the GE ToolboxST or similar control software environment to ensure the new hardware is recognized and integrated into the system logic correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51320392712504,"sku":"IS200EXHSG3AEC","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/12..jpg?v=1778228741","url":"https:\/\/www.automodulexpert.com\/de\/products\/mark-vi-is200exhsg3aec-high-speed-protection-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}