{"product_id":"power-supply-module-ge-ic697pwr711m-series-90-70","title":"Power Supply Module GE IC697PWR711M Series 90-70","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 100% Brand New GE IC697PWR711M supplies regulated DC power to the Series 90-70 PLC system. It converts 120\/240 VAC or 125 VDC input power into +5 VDC, +12 VDC, and -12 VDC output rails for the CPU, I\/O modules, and backplane. This module occupies the leftmost slot (Slot 0) of the IC697 rack and features a slide-in design for rapid installation. It supports single-rack applications and optionally powers a second expansion rack via an interconnect cable, provided the total load stays within the 100-watt rating.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC697PWR711M\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Series 90-70\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90-264 VAC (47-63 Hz) or 100-150 VDC\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Output Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 Watts Maximum\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput +5 VDC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 20 Amps (4.90 - 5.25 VDC)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput +12 VDC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 2 Amps (11.64 - 12.6 VDC)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOutput -12 VDC:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1 Amp (-12.6 to -11.64 VDC)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHold-Up Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e21 ms minimum (at full load)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eElectronic short-circuit, Overcurrent, Overvoltage (jumper selectable)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 0.93 (AC operation)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 Vrms (Input to Backplane\/Output)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLeftmost Slot (Slot 0), Slide-in Rack Mount\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e102.2 mm x 124 mm x 126 mm (approx.)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2 kg (Note: Literature typically lists ~1.7 kg; verify specific unit)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Rack Power Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module powers a primary rack and a secondary expansion rack simultaneously using a prewired interconnect cable. Engineers reduce hardware costs by avoiding a separate power supply for small satellite I\/O racks, as long as the combined 5V current draw does not exceed 20 Amps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Input Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide input range accepts 90-264 VAC or 100-150 VDC. Technicians deploy the same 100% Brand New spare globally without rewiring for regional power standards (120V\/240V AC) or DC battery backups (125V DC).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLine Disturbance Ride-Through:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe supply maintains output regulation for at least 21 milliseconds (minimum one AC line cycle) after input power loss. This ride-through capability prevents nuisance shutdowns during brief utility switching transients or contactor bounce, allowing the CPU to execute a controlled shutdown sequence.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eActive Power Factor Correction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit corrects the input power factor to greater than 0.93. This reduces harmonic distortion on the facility's AC line, minimizes wasted reactive power, and ensures compliance with industrial power quality standards, particularly in panels with multiple drives or switching power supplies.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIn which slot do I install the IC697PWR711M?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must install the power supply in the leftmost slot of the rack, designated as Slot 0. The module physically keys into the backplane power bus connector. Installation in any other slot will not power the rack and may cause physical damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this power supply run a CPU rack and an expansion rack at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. If the total 5V current draw of both racks is less than 20 Amps (100W total), you connect a standard IC697CBLxxx cable from the \"RACK 2\" connector on the power supply faceplate to the power connector on the second rack's backplane.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"-M\" suffix indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"-M\" denotes a specific manufacturing revision of the IC697PWR711. Electrically and mechanically, the IC697PWR711M functions as a direct replacement for all earlier revisions (A through L). The 100% Brand New module drops into existing systems without requiring software changes or reconfiguration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the overvoltage protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features a jumper (often labeled W1 or OVP) on the circuit board visible through the top vent. Technicians set this jumper to enable or disable the +5V overvoltage protection latch (trip point approx 5.7-6.7V). Consult the specific hardware manual for the jumper's default state and location on the \"-M\" revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52372552417592,"sku":"IC697PWR711M","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC697PWR711M2.jpg?v=1778812151","url":"https:\/\/www.automodulexpert.com\/es\/products\/power-supply-module-ge-ic697pwr711m-series-90-70","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}