{"product_id":"provibtech-tm0180-07-02-07-05-02-extension-cable","title":"PROVIBTECH TM0180-07-02-07-05-02 Extension Cable","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROVIBTECH TM0180-07-02-07-05-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision armored Proximity Probe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor non-contact measurement of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft displacement and vibration\u003c\/strong\u003e. Using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeddy current principle\u003c\/strong\u003e, it provides a voltage output proportional to the gap between the probe tip and the shaft. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estainless steel armor (code 02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects the integral cable from abrasion, impacts, and crushing, ensuring reliable long-term operation in harsh industrial environments. This makes it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAPI 670-compliant machine protection systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTM0180-07-02-07-05-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEddy Current Proximity Probe \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTM0180-07-02-07-05-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanically demanding environments\u003c\/strong\u003e, such as areas near sharp edges, maintenance traffic, or falling debris. Typical installations include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epump trains, fans, mixers, and large turbines\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e11 mm tip diameter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis preferred for larger shafts or slow-speed machinery, offering a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estable, representative vibration signal\u003c\/strong\u003e. The armored cable ensures continuous, reliable monitoring under physical stress.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3\u003eQ1: What is the purpose of the stainless steel armor?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt protects the probe’s internal cable from abrasion, minor impacts, and crushing, preventing signal degradation or failure.\u003c\/p\u003e\n\u003ch3\u003eQ2: Does the armor affect measurement accuracy?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The armor is electrically shielded and does not interfere with the probe’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAPI 670-standard 8 mV\/µm sensitivity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eQ3: Why choose an 11 mm tip diameter over 8 mm?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe larger tip provides a bigger measurement area, which improves signal stability and averaging, especially on large or imperfect shafts.\u003c\/p\u003e\n\u003ch3\u003eQ4: How does the probe connect to the monitoring system?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt connects to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProximity Probe Driver\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereverse-mount connector (code 02)\u003c\/strong\u003e, which powers the probe, conditions the signal, and outputs a voltage proportional to the shaft gap.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"PROVIBTECH","offers":[{"title":"Default Title","offer_id":51428071276856,"sku":"TM0180-07-02-07-05-02","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/TM0180-07-00-05-10-02.jpg?v=1764552987","url":"https:\/\/www.automodulexpert.com\/es\/products\/provibtech-tm0180-07-02-07-05-02-extension-cable","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}