{"product_id":"aai141-s00-s2-yokogawa-analog-input-module","title":"AAI141-S00 S2 Yokogawa Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI141-S00 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. It provides reliable acquisition of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA current signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom field transmitters, converting them into precise digital data for real-time monitoring and control.\u003c\/p\u003e\n\u003cp\u003eBuilt for mission-critical industrial environments, the AAI141-S00 S2 combines robust isolation, compact design, and enhanced long-term stability, making it a core component in high-availability control architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel High Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaximizes I\/O capacity per slot, reducing cabinet space requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4–20 mA Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccurate conversion of standard current-loop signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel group isolated from system circuits to protect against electrical noise and surges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with CENTUM VP redundant configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS2 Revision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImproved thermal stability and component reliability over earlier S1 models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI141-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 × 107 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cp\u003eThe AAI141-S00 S2 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas refineries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical measurements include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure, temperature, flow, and level transmitters\u003c\/strong\u003e, supporting precise PID control and process optimization.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAI141-S00 S2 be used with 2-wire transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module accepts 4–20 mA signals; however, loop power for 2-wire transmitters must be supplied externally or via a compatible power distributor, as this module uses a sink-type input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the S2 suffix indicate?\u003c\/strong\u003e\u003cbr\u003eA: S2 denotes an updated hardware revision with improved reliability and environmental compliance, while remaining fully compatible with S1 versions.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51661943865656,"sku":"AAI141-00 S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI141-00_S2.jpg?v=1769391860","url":"https:\/\/www.automodulexpert.com\/fa\/products\/aai141-s00-s2-yokogawa-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}