Allen-Bradley 1440-TPS02-01RB XM-320 Position Module

Allen-Bradley 1440-TPS02-01RB XM-320 Position Module
Allen-Bradley 1440-TPS02-01RB XM-320 Position Module
Allen-Bradley 1440-TPS02-01RB XM-320 Position Module
Allen-Bradley 1440-TPS02-01RB XM-320 Position Module
Allen-Bradley 1440-TPS02-01RB XM-320 Position Module
Allen-Bradley 1440-TPS02-01RB XM-320 Position Module

Allen-Bradley 1440-TPS02-01RB XM-320 Position Module

This 1440-TPS02-01RB XM-320 Position Module was manufactured by Allen-Bradley, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
Allen-Bradley
Part Number:
1440-TPS02-01RB
Type de produit:
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Overview

The XM-320 module (catalog number: 1440-TPS02-01RB) is designed to measure turbine supervisory position metrics, including axial position (thrust), valve position, differential expansion, and case expansion.

Specifications

Inputs

  • Channels: 2 channels
  • Signal Types:
    • Eddy current transducer signals
    • Linear variable differential transformer (LVDT)
    • Voltage signals from any position measurement sensor
  • Transducer Power: Isolated 24V, configurable for +24V or -24V wiring
  • Voltage Range: Selectable in software between -24V and +24V
  • Sensitivity: User-configurable in software
  • Input Impedance: > 100 kΩ

Outputs

  • 4…20mA Outputs:
    • Two isolated outputs
    • Max load: 600 Ω
  • Buffered Outputs: Two outputs (one per channel)

Indicators

  • Module Status: Red/green
  • Network Status: Red/green
  • Channel 1 Status: Yellow/red
  • Channel 2 Status: Yellow/red
  • Setpoint Multiplier Status: Yellow
  • Relay Status: Red

Communication

  • DeviceNet Network:
    • Standard DeviceNet protocol for all functions (module power provided independently)
    • EDS file available for support with most DeviceNet-compliant systems
    • Automatic communication rate setting: 125, 250, or 500 Kbps
    • Configurable I/O Poll Response message for space optimization within scanner input tables:
      • Selectable poll response assembly
      • Selectable poll response size (bytes)
  • Serial Communication:
    • RS-232 via mini-connector or terminal base unit
    • Fixed communication rate of 19.2 Kbps
    • Local configuration via Serial Configuration utility

Measurement Modes

  • Normal: Two independent channels
  • Head-to-head
  • Radial cancel

Delta Time Buffer

  • Number of Records: 2048
  • Delta Time Interval: 1 to 3600 seconds
  • Trigger Mode: Triggered by relay activation or a DeviceNet command from a controller or host

Alarms

  • Number of Alarms: Two alarm and danger pairs
  • Operators:
    • Greater than
    • Less than
    • Inside range
    • Outside range
  • Hysteresis: User-configurable in software
  • Startup Inhibit/Setpoint Multiplication:
    • Period: 0 to 1092 minutes, adjustable in 0.1-minute increments
    • Inhibit/multiplication function: Multiply by N (0 to 10, 0 = Disarm)

Relays

  • Number of Relays:
    • Single on-board relay with two sets of DPDT contacts (2 Form C)
    • Four additional relays with XM-441 expansion relay module
    • Four virtual relays (status can be used by remote control systems or XM-440 master relay module)
  • On-board Relay Rating:
    • Max Voltage: 125V DC, 125V AC
    • Max Current: 3.5 A (derates to 2 A at 65°C / 149°F)
    • Max Power: 60 W (DC), 62.5 VA (AC)
  • Failsafe Options:
    • Normally energized (failsafe)
    • Normally de-energized (non-fail-safe)
  • Latching Options:
    • Latching
    • Non-latching
  • Time Delay: Adjustable from 0 to 25.5 seconds in 100 ms increments
  • Logic: Single or paired AND or OR logic for alarm triggers
  • Reset Options:
    • Local reset switch on top of module
    • Remote reset switch via terminal base
    • Digital reset command via serial or DeviceNet interface

Configuration

  • Non-volatile Configuration:
    • Configuration is stored in non-volatile memory and is loaded on power-up
    • Configuration can be deleted only by module reset via serial or DeviceNet interface

Power

  • Module Power: 24V DC
  • Power Consumption:
    • Max: 200 mA
    • Typical: 165 mA
  • Heat Production:
    • Max: 5.28 W (18 BTU/hr)
    • Typical: 3.96 W (13.5 BTU/hr)

Physical Specifications

  • Terminal Base: 1440-TB-B
  • Dimensions (H x W x D): 97 x 94 x 94 mm (3.8 x 3.7 x 3.7 in.)
Devis rapides Recevez rapidement le prix & la disponibilité de notre équipe de service client dédiée.
Distribution Expédition accélérée, fret et expédition internationale disponibles.
État 100 % Neuf avec emballage d'origine
Paiement Nous acceptons American Express, Discover, MasterCard, PayPal et Visa. Notre site est sécurisé par RapidSSL.
Port de livraison ShangHai, Xiamen
Garantie 12 mois
Q : Nos prix sont-ils compétitifs ?
A : Oui, nous collaborons avec plus de 50 pays dans le monde. En tant que fournisseur de premier plan en Chine, nous offrons des remises importantes basées sur les tendances du marché.
Q : Quelle est la durée de la garantie ?
A : Tous nos produits neufs et d'origine bénéficient d'une garantie standard d'un an.
Q : Quels modes de paiement acceptons-nous ?
A : Nous exigeons un paiement de 100 % par T/T (virement télégraphique) avant l'expédition. Pour les articles avec un délai de fabrication, un acompte de 30 % est demandé à l'avance, et les 70 % restants sont dus avant l'expédition. Si vous avez un représentant en Chine, vous pouvez organiser un transfert en RMB par son intermédiaire.
Q : Quels modes d'expédition utilisons-nous ?
A : Nous utilisons principalement FedEx, DHL, UPS et BRE pour l'expédition. Si vous avez un compte chez l'un de ces transporteurs, vous pouvez gérer l'expédition directement. Nous offrons également la livraison gratuite aux transitaires basés en Chine.
Q : Quel est notre délai de livraison ?
A : La livraison prend généralement 1 à 3 jours après réception du paiement initial. Pour les articles avec un délai de fabrication, l'expédition se fera selon le calendrier spécifié.
Q : Comment emballons-nous les marchandises ?
A : Nous assurons un emballage sécurisé avec plusieurs couches de protection. Les produits sont d'abord placés dans leurs boîtes d'origine et scellés avec des étiquettes. Une couche de papier bulle est ensuite ajoutée pour protéger contre les chocs pendant le transport. Enfin, les articles sont emballés solidement dans des boîtes durables.
Q : Comment les clients peuvent-ils nous contacter et demander un devis ?
A : Vous pouvez nous contacter par email, WhatsApp, WeChat, Skype ou via votre plateforme de communication préférée. Contactez-nous avec vos besoins, et nous vous fournirons un devis rapide et personnalisé.
 

Récemment consulté

Express Shipping icon
Expédition Express
Livraison rapide pour vos besoins urgents.
Large stock icon
Inventaire étendu
Grand stock pour expédition immédiate.
Quality Assurance Icon
Assurance qualité
Composants PLC et DCS authentiques et de première qualité.
Global Service icon
Service mondial
Soutenir les clients dans le monde entier avec un service fiable.