EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier

EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier
EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier
EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier
EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier

EPRO | MMS 6410 | MMS6410 | Dual Channel Measuring Amplifier

This MMS 6410 Dual Channel Measuring Amplifier was manufactured by EPRO, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
EPRO
Part Number:
MMS 6410
Country of Origin:
Germany
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Overview

The MMS 6410 is a Dual Channel Measuring Amplifier for inductive displacement sensors, designed for precise measurements in various industrial applications.

Technical Specifications

  • Sensor Inputs:

    • Two independent inputs for inductive sensors in half- or full bridge configuration and for differential transformers.
    • The signal inputs are differential inputs, galvanically isolated from the system supply, open circuit and short circuit proof.
  • Max. Input Voltage:

    • 3.6 V (protected against over voltages)
  • Nominal Input Voltage Range:

    • 2.5 V rms
  • Input Impedance:

    • 200 kOhm
  • Measuring Ranges:

    • Measuring frequency range: 0....100 Hz -3dB
    • Measuring range displacement measurement: Depending on transducer measuring range; one or both outputs may be inverted.
  • Sensor Supply:

    • Each input includes a separate, buffered output to supply inductive sensors.
    • Carrier Frequency: 4.75 kHz
    • Nominal Supply Voltage: 4 Vrms
    • Permissible Load: 120....600 Ohm
    • The outputs are balanced to ground, open-circuit and short-circuit proof.
  • Control Inputs:

    • Common logical binary inputs for the two channels.
    • Optocoupler Mode:
      • "Pre-alarm (ALERT)", open circuit or closed circuit mode
      • "Main alarm (DANGER)", open circuit or closed circuit mode
      • Channel or module inhibit
      • Limit value multiplier for changing alarm limits during run-up and run-down of the machine, adjustable in the range: 1.000....4.999
      • 24 V Logic
      • Input Resistance: > 10 kOhm
  • Key Pulse Input:

    • 1 pulse per revolution for analysis purposes of the system.
    • 24 V Logic
    • Input Resistance: > 30 kOhm
    • Pulse Duration: min. 10 µs (edge-triggered)

Signal Outputs at the Connecting Strip

  • Connecting Strip: according to type F48M, DIN41612
  • Communication Interface: RS485
  • Outputs:
    • Current Output per Channel:
      • Nominal range: 0/4...20 mA
      • Open circuit and short-circuit proof
      • Permissible Burden: ≤500 Ohm
      • Resolution: 16 Bit
      • Accuracy: ±1% of f.s.d.
    • Voltage Output per Channel:
      • Nominal range: 0...+10 V
      • Open circuit and short-circuit proof
      • Load Resistance: ≥10 kOhm
      • Resolution: 8 Bit
      • Accuracy: ±1 % of f.s.d
    • Voltage Output per Channel (Sensor Signal):
      • Nominal range: 0...12 Vpp
      • Open circuit and short-circuit proof
      • Load Resistance: ≥100 kOhm
      • Frequency Range: 0 Hz...20 kHz (±20 % -3 dB)
      • Accuracy: ±1 % of f.s.d

Operating Elements at the Module Front

  • Two sensor signal outputs, independently from each other, one for each channel.
  • The signals are proportional to the sensor signals and can be tapped at the SMB sockets on the module front.
  • Range: ±12 V
  • Load Resistance: 100 kOhm
  • Internal Resistance: 1 kOhm
  • Frequency Range: Dynamic carrier frequency output with superimposed displacement signal.
  • LED Indicators:
    • 2 green LEDs for "Channel Clear" separately for channel 1 and channel 2.
    • 4 red LEDs for pre and main alarm separately for both channels.
  • Mini DIN Diode Socket: RS232 interface for connection of a computer for configuration and data interchange with the module.
  • Handle: To pull out and insert the module and for labeling purposes.

Power Supply

  • System Design: Redundant supply input via two supply inputs, decoupled via diodes. At least one supply input is required for the supply of the module.
  • Supply Voltage: 18....24....31.2 V DC according to IEC 654-2, class DC4
  • Power Consumption: max. 8 W (max. 300 mA at 24 V)
  • Other supply voltages can be realized with additional system power supplies.
  • At standalone operation, an unlimited number of modules.
  • Max. 31 modules / 62 channels may be operated at one RS 485 bus.
  • If more modules / channels are necessary, e.g. with an MMS 6815, another RS 485 bus must be installed.

Environmental Conditions

  • Protection Class:
    • Module: IP 00 according to DIN 40050
    • Front Plate: IP21 according to DIN 40050
  • Climate Conditions: according to DIN 40040 class KTF
  • Operating Temperature Range: 0....+65°C
  • Temperature Range for Storage and Transport: -30....+85°C
  • Permissible Relative Humidity: 5....95%, non-condensing
  • Permissible Vibration: according to IEC 68-2, part 6
    • Vibration Amplitude: 0.15 mm in range 10...55 Hz
    • Vibration Acceleration: 16.6 m/s² in range 55...150 Hz
  • Permissible Shock: according to IEC 68-2, part 29
    • Peak Value of Acceleration: 98 m/s²
    • Nominal Shock Duration: 16 ms
  • EMC Resistance: according to EN50081-1 / EN50082-2

Dimensions

  • PCB/EURO Card Format: acc. to DIN 41494 (100 x 160 mm)
  • Width: 30.0 mm (6 TE)
  • Height: 128.4 mm (3 HE)
  • Length: 160.0 mm
  • Net Weight: approx. 320 g
  • Space Requirements: 14 modules (28 channels) fit into each 19“ rack
Brze ponude Primite cijenu i dostupnost BRZO od našeg posvećenog tima za korisničku podršku.
Dostava Dostupna je ubrzana, teretna i međunarodna dostava.
Stanje 100% Novo s originalnom ambalažom
Plaćanje Prihvaćamo American Express, Discover, MasterCard, PayPal i Visa. Naša stranica je osigurana RapidSSL-om.
Luka za otpremu ShangHai, Xiamen
Jamstvo 12 mjeseci
Q: Jesu li naše cijene konkurentne?
A: Da, surađujemo s više od 50 zemalja širom svijeta. Kao vodeći dobavljač u Kini, nudimo značajne popuste temeljem tržišnih trendova.
Q: Koje je jamstveno razdoblje?
A: Svi naši novi i originalni proizvodi dolaze sa standardnim jamstvom od jedne godine.
Q: Koje metode plaćanja prihvaćamo?
A: Zahtijevamo 100% T/T (telegrafski transfer) uplatu prije otpreme. Za artikle s rokom isporuke, potrebno je unaprijed uplatiti 30% depozita, a preostalih 70% prije otpreme. Ako imate predstavnika u Kini, možete preko njega dogovoriti prijenos RMB.
Q: Koje metode dostave koristimo?
A: Uglavnom koristimo FedEx, DHL, UPS i BRE za dostavu. Ako imate račun kod bilo kojeg od ovih prijevoznika, možete sami obaviti otpremu. Također nudimo besplatnu dostavu za špeditere sa sjedištem u Kini.
Q: Koje je naše vrijeme isporuke?
A: Dostava obično traje 1-3 dana nakon primitka početne uplate. Za artikle s rokom isporuke, otprema će se izvršiti prema navedenom rasporedu.
Q: Kako pakiramo robu?
A: Osiguravamo sigurno pakiranje s višestrukim slojevima zaštite. Proizvodi se prvo stavljaju u njihove originalne kutije i zatvaraju naljepnicama. Zatim se dodaje sloj mjehurićaste folije za zaštitu od udaraca tijekom transporta. Na kraju, predmeti se sigurno pakuju u čvrste kutije.
Q: Kako nas kupci mogu kontaktirati i zatražiti ponudu?
A: Možete nas kontaktirati putem e-pošte, WhatsAppa, WeChata, Skypea ili vaše omiljene komunikacijske platforme. Obratite nam se sa svojim potrebama, a mi ćemo vam pružiti brzu, prilagođenu ponudu.
 

Nedavno pregledano

Express Shipping icon
Ekspresna dostava
Brza dostava za vaše hitne zahtjeve.
Large stock icon
Opsežan inventar
Veliki lager za trenutnu dostavu.
Quality Assurance Icon
Osiguranje kvalitete
Autentične, vrhunske PLC i DCS komponente.
Global Service icon
Globalna usluga
Podrška klijentima širom svijeta pouzdanom uslugom.