{"product_id":"1734-adn-allen-bradley-point-i-o-devicenet-network-adapter","title":"1734-ADN | Allen-Bradley POINT I\/O DeviceNet Network Adapter","description":"\u003ch2\u003eAllen-Bradley 1734-ADN POINT I\/O DeviceNet Network Adapter\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1734-ADN\u003c\/strong\u003e is a POINT I\/O DeviceNet network adapter that links POINT I\/O expansion modules to a DeviceNet network for distributed field control. It supports up to 63 POINT I\/O modules, selectable data rates of 125, 250, and 500 kbps, and up to 248 bytes of input and 248 bytes of output data. Powered from a 10-28.8 VDC range (nominal 24 VDC), it mounts on a DIN rail and has no onboard I\/O channels.\u003c\/p\u003e\n\u003ch3\u003eDeviceNet Communication and POINTBus Expansion\u003c\/h3\u003e\n\u003cp\u003eActing as the head-end interface for a POINT I\/O bank, the \u003cstrong\u003e1734-ADN\u003c\/strong\u003e exchanges I\/O data between DeviceNet controllers and up to 63 attached POINT I\/O modules over the POINTBus. Because the adapter includes 0 integrated I\/O channels, all field signal points are provided by the connected POINT I\/O modules.\u003c\/p\u003e\n\u003cp\u003eConfiguration, node setup, and diagnostics are performed using RSNetWorx for DeviceNet. Selectable communication rates of 125, 250, and 500 kbps let system engineers balance trunk cable distance (up to 500 m at 125 kbps) against network scan timing.\u003c\/p\u003e\n\u003ch3\u003ePower Budget, Diagnostics, and Mounting\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e1734-ADN\u003c\/strong\u003e operates from a 10-28.8 VDC supply (24 VDC nominal), draws up to 30 mA on the DeviceNet side, and supplies up to 1 A at 5 VDC on the POINTBus. When expanding a POINT I\/O bank, verify that total module current draw on the POINTBus stays within the 1 A limit or add power distribution as required by the system layout.\u003c\/p\u003e\n\u003cp\u003eStatus LEDs cover Module, DeviceNet, POINTBus, System Power, and Field Power to aid commissioning and fault isolation. The adapter mounts on a DIN rail, with operating temperature listed as -20 to 55 deg C in the specification table and 0 deg C to +55 deg C in the overview table.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-ADN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePOINT I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Network Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Modules\u003c\/td\u003e\n\u003ctd\u003eUp to 63 POINT I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Data\u003c\/td\u003e\n\u003ctd\u003e248 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Data\u003c\/td\u003e\n\u003ctd\u003e248 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e125 \/ 250 \/ 500 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Network Distance\u003c\/td\u003e\n\u003ctd\u003e500 m at 125 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10-28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Current Consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOINTBus Current Capacity\u003c\/td\u003e\n\u003ctd\u003e1 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eModule, DeviceNet, POINTBus, System Power, Field Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eRSNetWorx for DeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C (0 deg C to +55 deg C in overview table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e75 x 55 x 35 mm (supplier-listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg (supplier-listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: How many POINT I\/O modules and how much I\/O data can the 1734-ADN handle? A: It supports up to 63 POINT I\/O modules and up to 248 input bytes plus 248 output bytes, while providing 0 onboard I\/O channels itself. Actual module count and data size depend on the specific POINT I\/O modules installed and your DeviceNet scanner configuration in RSNetWorx for DeviceNet.\u003c\/p\u003e\n\u003cp\u003eQ: What power and POINTBus current limits must be checked when configuring the adapter? A: The module runs on 10-28.8 VDC (24 VDC nominal), draws 30 mA from DeviceNet, and provides up to 1 A at 5 VDC on the POINTBus. Confirm that connected POINT I\/O modules do not exceed the 1 A POINTBus capacity or require additional power provisioning.\u003c\/p\u003e\n\u003cp\u003eQ: What status indicators are provided for troubleshooting on the 1734-ADN? A: It includes status indicators for Module, DeviceNet, POINTBus, System Power, and Field Power. Check power rails and bus indicators together during startup to separate field power, backplane\/POINTBus, and network communication issues.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51474798575928,"sku":"1734-ADN","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/1734-ADN1_8f5dc7ce-ce58-40b4-ad7f-4c44e16ab3ed.jpg?v=1764902451","url":"https:\/\/www.automodulexpert.com\/products\/1734-adn-allen-bradley-point-i-o-devicenet-network-adapter","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}