{"product_id":"1769-aentr-allen-bradley-compactlogix-ethernet-ip-communication-adapter","title":"1769-AENTR Allen-Bradley CompactLogix EtherNet\/IP Communication Adapter","description":"\u003ch2\u003eAllen-Bradley 1769-AENTR CompactLogix EtherNet\/IP Adapter\u003c\/h2\u003e\n\u003cp\u003eConfigured for distributed I\/O integration in CompactLogix controller platforms, the \u003cstrong\u003eAllen-Bradley 1769-AENTR\u003c\/strong\u003e (\u003cstrong\u003e1769-AENTR\u003c\/strong\u003e EtherNet\/IP Adapter) provides direct physical\/electrical execution. This module establishes a high-speed communication interface connecting local 1769 Compact I\/O expansion banks to a primary Logix Programmable Automation Controller (PAC) via deterministic industrial networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-AENTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.62 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 mm x 118 mm x 87 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC system backplane bus power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 Ethernet (Category 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eDevice Level Ring (DLR), Linear, Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003e2 G @ 10 to 500 Hz \/ 15 G operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Torque\u003c\/td\u003e\n\u003ctd\u003e1.16 Nm (10 in-lb) using M4 or #8 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet Interface \u0026amp; Backplane Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe module operates as an Ethernet bridge that manages communication traffic between host PACs and local I\/O modules. Featuring embedded switch capability, the unit supports dual-port infrastructure designed for Device Level Ring (DLR) and linear topologies. DLR architecture provides single-fault network recovery, which maintains deterministic message delivery if a cable failure occurs. The internal backplane bus interface handles cyclic I\/O data updating, module configuration traffic, and fault diagnostics across connected 1769 I\/O cards. Firmware compatibility requires Studio 5000 or RSLogix 5000 v20 or higher, utilizing a dedicated Add-On Profile (AOP) for hardware identification and module parameterization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the two RJ45 Ethernet ports on the module be configured with distinct IP addresses?\u003c\/p\u003e\n\u003cp\u003eA: No. The two Ethernet ports share a single network interface and operate through an embedded two-port switch. Both physical ports utilize the exact same IP address to facilitate linear and DLR ring topologies.\u003c\/p\u003e\n\u003cp\u003eQ: What software version is required to configure and operate the module?\u003c\/p\u003e\n\u003cp\u003eA: Hardware configuration requires RSLogix 5000 or Studio 5000 software version 20 or higher, along with the corresponding Add-On Profile (AOP) installed in the programming environment.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary immunity ratings for electromagnetic interference on communication lines?\u003c\/p\u003e\n\u003cp\u003eA: The communication ports withstand Conducted RF immunity up to 10 V rms (150 kHz to 80 MHz), EFT\/B immunity up to +\/-3 kV at 5 kHz, and Surge transient immunity up to +\/-2 kV line-to-earth.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDuring physical installation, secure the adapter module onto a standard 35 mm DIN rail or bolt it directly to a grounded panel using M4 or #8 hardware tightened to a torque of 1.16 Nm (10 in-lb). Maintain proper physical grounding by ensuring the DIN rail connects to the central enclosure ground plane through low-impedance copper conductors. Route all Category 5 industrial Ethernet cabling away from high-voltage power lines, variable frequency drives, and heavy inductive loads to prevent electromagnetic coupling. Shielded twisted-pair (STP) Ethernet cabling must be grounded at cable termination points to maintain compliance with CISPR 11 Class A emission standards and protect against electrostatic discharge (6 kV contact, 8 kV air). Maintain adequate vertical clearance around the module housing to allow natural convection cooling within the 0 to 60 deg C operating range.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52905838543160,"sku":"1769-AENTR","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/290..jpg?v=1788483559","url":"https:\/\/www.automodulexpert.com\/products\/1769-aentr-allen-bradley-compactlogix-ethernet-ip-communication-adapter","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}