{"product_id":"1769-rtbn10-allen-bradley-compactlogix-terminal-block","title":"1769-RTBN10 Allen-Bradley CompactLogix Terminal Block","description":"\u003ch2\u003eAllen-Bradley 1769-RTBN10 CompactLogix Removable Terminal Block\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-RTBN10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1769-RTBN10\u003c\/strong\u003e Removable Terminal Block, operates as a dedicated hardware component for field wiring termination and module isolation within CompactLogix control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-RTBN10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard 1769 Terminal Assembly Mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CompactLogix 1769 Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Count\u003c\/td\u003e\n\u003ctd\u003e10-Position Screw-Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.34 to 2.5 mm2 (22 to 14 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 to 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e1769 Compact I\/O Modules (CompactLogix \/ MicroLogix 1500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Rating\u003c\/td\u003e\n\u003ctd\u003eClass I, Div 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Determinism\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1769-RTBN10 maintains physical continuity for discrete and analog signals entering 1769 Compact I\/O modules, preserving backplane bus communication velocity by ensuring low-resistance field wiring pathways. Stable screw-clamp contact retention prevents intermittent signal dropouts and noise coupling, which safeguards deterministic EtherNet\/IP data transfer and firmware flash compatibility between local I\/O expansion racks and central processing units.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1769-RTBN10 terminal block be removed or inserted while field power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Removing or inserting the terminal block under load can cause electrical arcing, which may damage contact pins or trigger field-side faults; field power must be isolated prior to disconnecting the assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Does replacing an I\/O module require disconnecting field wires from the 1769-RTBN10?\u003c\/p\u003e\n\u003cp\u003eA: No, the removable mechanism allows the complete 10-position wire harness assembly to unlatch intact from the module housing, preserving field wiring terminations during module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify that all system backplane power and field wiring supply voltage sources are de-energized before mounting or servicing the terminal block. Align the 1769-RTBN10 with the front retention slots of the target 1769 Compact I\/O module and press firmly until the locking latches engage fully. Strip field conductors to the specified insulation length and insert 22 to 14 AWG wire leads into the designated screw-clamp terminals. Tighten terminal screws to a torque rating between 0.5 and 0.6 Nm to establish gas-tight contact while avoiding thread damage. Route wire bundles neatly through cabinet wire ducts to minimize mechanical strain on the terminal assembly.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52902599098680,"sku":"1769-RTBN10","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/281..jpg?v=1788425671","url":"https:\/\/www.automodulexpert.com\/products\/1769-rtbn10-allen-bradley-compactlogix-terminal-block","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}