{"product_id":"3301-s2-di3301s2-triconex-digital-input-module","title":"3301 S2 DI3301S2 Triconex Digital Input Module","description":"\u003ch2\u003eTriconex 3301 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTriconex DI3301S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3301 S2\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for field sensor signal acquisition within Triconex safety instrumented system platforms. The module conditions and digitizes discrete signals originating from field switches and contacts. Operating with a nominal 24 VDC threshold, each channel evaluates field contact status and transmits discrete logic states to the main processor backplane without signal corruption.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3301 S2 (DI3301S2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.42 kg packed assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.9 cm x 3.8 cm x 24.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 6 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Voltage Range\u003c\/td\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e4 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel to logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Delay\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGalvanic Isolation and Triple Modular Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe 3301 S2 incorporates channel-to-logic galvanic isolation rated at 1500 VAC to protect internal processing circuits from field-side voltage transients and ground loops. Within the Triple Modular Redundancy (TMR) architecture, incoming signals pass to three separate processing legs. Each leg processes input transitions with a 4 ms signal delay, forwarding logical states to the main processor triplicated bus for 2oo3 voting execution. Internal diagnostic routines continuously verify input circuit health and logic states to force immediate fail-safe state execution upon detecting a channel fault.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal delay filter applies to field contact transitions on the 3301 S2?\u003c\/p\u003e\n\u003cp\u003eA: The module maintains a fixed input signal delay of 4 ms to suppress mechanical contact chatter and transient voltage spikes before logic state evaluation.\u003c\/p\u003e\n\u003cp\u003eQ: What operational voltage boundary applies to the discrete input channels?\u003c\/p\u003e\n\u003cp\u003eA: The input channels operate across a voltage range of 15 to 30 VDC, drawing a nominal input current of 6 mA with an input impedance of 4 kOhm.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module isolate field voltage surges from the system chassis?\u003c\/p\u003e\n\u003cp\u003eA: Optical galvanic isolation barriers rated to 1500 VAC decouple the 32 field input channels from the backplane logic bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the 3301 S2 module directly into its assigned I\/O chassis slot until the locking latches fully seat against the backplane connector frame. Fasten panel retaining screws to secure chassis ground continuity. Separate incoming 24 VDC signal wiring from AC power lines inside cabinet wiring ducts, maintaining at least 30 cm clearance to eliminate electromagnetic interference. Verify correct field polarity across all 32 terminal points before applying power. Ensure cabinet circulation fans maintain ambient operating temperatures within the specified -40 to 70 deg C range.\u003c\/p\u003e","brand":"TRICONEX","offers":[{"title":"Default Title","offer_id":51181558464824,"sku":"DI3301S2","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/255..jpg?v=1788251608","url":"https:\/\/www.automodulexpert.com\/products\/3301-s2-di3301s2-triconex-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}