{"product_id":"51304754-150-honeywell-mc-paih03-analog-input-processor-module","title":"51304754-150 Honeywell MC-PAIH03 Analog Input Processor Module","description":"\u003ch2\u003eHoneywell 51304754-150 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304754-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-PAIH03\u003c\/strong\u003e High Level Analog Input Processor, operates as a dedicated hardware component for multi-channel process variable acquisition within Honeywell TDC 3000 and Experion PKS platforms. The unit accepts 16 differential analog inputs, processing 4-20 mA current loops, 0-5 V, 1-5 V, and 0.4-2 V voltage signals, alongside thermocouples and RTDs. High-resolution 16-bit A\/D conversion coupled with channel-to-bus isolation ensures accurate digitization across an operating temperature range of 0 deg C to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304754-150 (MC-PAIH03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Outlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg to 0.60 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 x 178 x 356 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 differential analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types Supported\u003c\/td\u003e\n\u003ctd\u003eVoltage (0-5 V, 1-5 V, 0.4-2 V), Current (4-20 mA via 250 ohm resistor), Thermocouples (J, K, T, E, R, S, B), RTDs (Pt100, Ni120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D (14 bits utilized); +-0.075% FS accuracy at 23.5 deg C +- 2 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 Mohm (voltage mode), 250 ohm (current mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise \u0026amp; Surge Protection\u003c\/td\u003e\n\u003ctd\u003eCommon mode rejection: 70 dB; Normal mode rejection: 32 dB at 60 Hz; ANSI\/IEEE C37.90.1-1978 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Limits\u003c\/td\u003e\n\u003ctd\u003eStorage: -40 deg C to +85 deg C; Humidity: 5-95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS, TDC 3000 platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation (CJC) and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 51304754-150 module utilizes channel-to-bus optical isolation barriers to decouple field-side measurement signals from host backplane logic. When configured for direct thermocouple interface leads (types J, K, T, E, R, S, B), the assembly integrates cold junction compensation (CJC) referencing to prevent ambient terminal temperature drifts from introducing measurement offsets. For standard 4-20 mA current loops, an internal 250 ohm precision resistor converts loop current to voltage drops while maintaining high common-mode noise rejection across adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle signal noise and isolation across differential channels?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates channel-to-bus optical isolation per IEC 61131-2 alongside a 70 dB common-mode noise rejection network, preventing ground loop transients and high-frequency interference from affecting A\/D conversion accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What is the scan timing cycle for reading all 16 differential channels?\u003c\/p\u003e\n\u003cp\u003eA: The internal A\/D converter executes continuous analog sampling at a fixed rate of 4 samples per second per channel, ensuring synchronized data refresh intervals across the host DCS backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How are 4-20 mA current signals termination-matched on the module inputs?\u003c\/p\u003e\n\u003cp\u003eA: Current loops route through integrated 250 ohm precision sensing resistors, providing standard 1-5 V input conversion while presenting a predictable load impedance to field transmitters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the 51304754-150 card vertically into the assigned slot of the Honeywell I\/O chassis, ensuring the edge connector seats completely into the backplane bus. Tighten the card retaining fasteners to maintain chassis grounding continuity and mechanical resistance against industrial vibration. Ensure cabinet layout permits adequate airflow to maintain ambient enclosure temperatures within 0 deg C to +60 deg C.\u003c\/p\u003e\n\u003cp\u003eRoute field sensor wiring through dedicated cable channels separate from high-voltage distribution lines and motor control circuits. Use twisted shielded conductors for all thermocouple, RTD, voltage, and 4-20 mA current loop runs. Terminate cable drain shields at the cabinet single-point ground bus bar only, leaving field sensor ends ungrounded to prevent circulating ground currents.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51260694233400,"sku":"51304754-150","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/269.1.jpg?v=1788333301","url":"https:\/\/www.automodulexpert.com\/products\/51304754-150-honeywell-mc-paih03-analog-input-processor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}