{"product_id":"745-w2-p5-g5-hi-a-l-r-e-h-transformer-protection-relay-general-electric","title":"745-W2-P5-G5-HI-A-L-R-E-H Transformer Protection Relay General Electric","description":"\u003cp\u003eConfigured for power transformer protection and fault analysis in electrical utility networks, the \u003cstrong\u003eGeneral Electric 745-W2-P5-G5-HI-A-L-R-E-H\u003c\/strong\u003e (\u003cstrong\u003e745-W2-P5-G5-HI-A-L-R-E-H\u003c\/strong\u003e Transformer Protection Relay) provides direct physical and electrical execution of protection elements and monitoring logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e745-W2-P5-G5-HI-A-L-R-E-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21.5 cm x 23 cm x 25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to auxiliary control voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTransformer Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 745-W2-P5-G5-HI-A-L-R-E-H utilizes deterministic network integration to report fault events, such as differential current transients or over-excitation conditions, to central control stations. Firmware flash compatibility is mandatory to align the relay's internal protection logic with current site standards. Users must verify bus communication velocity to ensure that the relay’s response time does not exceed the protection coordination limits established for the substation network. Stable communication is required to prevent packet loss during time-critical trip sequences.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 745-W2-P5-G5-HI-A-L-R-E-H relay be removed from its case while the protection system is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal CT (current transformer) circuits must be shorted using the relay case draw-out mechanism or external shorting blocks before the unit is extracted to prevent hazardous high-voltage conditions on secondary circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How is the firmware version verified for integration?\u003c\/p\u003e\n\u003cp\u003eA: Firmware versions must be confirmed through the relay’s front panel interface or via the serial\/Ethernet communication port using the manufacturer's software utility before upgrading or replacing components in a protection scheme.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is installed in a secure rack or panel environment. Maintain the specified dimensions (21.5 cm x 23 cm x 25 cm) to facilitate proper heat dissipation and accessibility for wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate current transformer (CT) and voltage transformer (VT) inputs using industry-standard ring lugs. Ensure all torque specifications for terminal block connections are met to prevent high-resistance joints.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the relay chassis ground terminal directly to the substation ground grid using a low-impedance copper conductor. This is required for transient voltage surge suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Following physical installation, perform a secondary injection test to verify trip logic and CT polarity before the transformer is returned to service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52638845731128,"sku":"745-W2-P5-G5-HI-A-L-R-E-H","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/745-W2-P5-G5-HI-A-L-R-E-H1.jpg?v=1784017267","url":"https:\/\/www.automodulexpert.com\/products\/745-w2-p5-g5-hi-a-l-r-e-h-transformer-protection-relay-general-electric","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}