{"product_id":"745-w2-p5-g5-hi-r-e-transformer-protection-relay-general-electric","title":"745-W2-P5-G5-HI-R-E Transformer Protection Relay General Electric","description":"\u003cp\u003eConfigured for power system monitoring and fault detection in electrical grid protection networks, the \u003cstrong\u003eGeneral Electric 745-W2-P5-G5-HI-R-E\u003c\/strong\u003e (\u003cstrong\u003e745-W2-P5-G5-HI-R-E\u003c\/strong\u003e Transformer Protection Relay) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e745-W2-P5-G5-HI-R-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21.5 cm x 23 cm x 25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Function\u003c\/td\u003e\n\u003ctd\u003eTransformer Differential Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe 745-W2-P5-G5-HI-R-E relay utilizes high-speed internal bus architectures to ensure deterministic response times during fault conditions. This unit is engineered to manage complex signal processing required for transformer differential and restricted earth fault protection. Integration into substation automation systems allows for continuous monitoring of harmonic restraint and inrush blocking logic. Data exchange between the protection core and external communication ports follows strict timing protocols to maintain synchronization with system-wide event recording, ensuring that transient analysis remains accurate within the sub-millisecond range required for primary electrical protection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary considerations for firmware upgrades on this relay?\u003c\/p\u003e\n\u003cp\u003eA: Firmware flash compatibility must be verified against the existing bootloader version. Ensure the relay is in a non-trip, maintenance mode before initiating any communication port file transfer to prevent accidental relay operation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the relay logic handled during power cycle events?\u003c\/p\u003e\n\u003cp\u003eA: The device employs non-volatile memory to retain setpoints and protection logic configurations. Upon restoration of auxiliary power, the relay performs a self-diagnostic sequence to confirm hardware integrity before transitioning to a protective monitoring state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet provides sufficient clearance to accommodate the 21.5 cm x 23 cm x 25 cm chassis dimensions, allowing for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eTerminate all Current Transformer (CT) and Voltage Transformer (VT) inputs using torque-specified fasteners to maintain low-resistance connections.\u003c\/li\u003e\n\u003cli\u003eConnect the dedicated chassis ground lug to the substation main earth bus using a flexible braided conductor to minimize impedance against high-frequency fault currents.\u003c\/li\u003e\n\u003cli\u003eRoute all communication cabling and low-voltage binary I\/O signals through dedicated conduit paths, physically separated from high-voltage primary conductors to prevent inductive noise injection.\u003c\/li\u003e\n\u003cli\u003eVerify that all terminal block wiring is securely fastened; inspect for proper wire gauge engagement as specified in the standard GE industrial interface documentation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52641512620344,"sku":"745-W2-P5-G5-HI-R-E","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/745-W2-P5-G5-HI-R-E1.jpg?v=1784102482","url":"https:\/\/www.automodulexpert.com\/products\/745-w2-p5-g5-hi-r-e-transformer-protection-relay-general-electric","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}