{"product_id":"8-channel-analog-output-module-abb-ao810v2-3bse038415r1","title":"8 Channel Analog Output Module ABB AO810V2 3BSE038415R1","description":"\u003ch2\u003eABB AO810V2 S800 I\/O Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AO810V2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAO810\u003c\/strong\u003e Analog Output Module (Article Number \u003cstrong\u003e3BSE038415R1\u003c\/strong\u003e), operates as a dedicated hardware component for converting digital control commands into 0-20 mA or 4-20 mA unipolar current signals within ABB System 800xA and S800 I\/O platforms. Driving eight non-redundant unipolar channels, the unit provides fast signal conversion to positioners, control valves, and field actuators. Onboard supervisory circuits continuously check external process power levels and channel output currents, reporting open-circuit conditions and hardware faults directly over the ModuleBus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAO810V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE038415R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm x 119 mm x 102 mm (1.77 in x 4.68 in x 4.01 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C (+32 deg F to +131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 V ModuleBus: Max 70 mA; +24 V external: 245 mA (Typ. 2.3 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 unipolar analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Resolution\u003c\/td\u003e\n\u003ctd\u003e14-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 500 Ohm (L1+ supply), 250-850 Ohm (L2+ supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Accuracy\u003c\/td\u003e\n\u003ctd\u003eMax error 0.1% (0-500 Ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003eTyp. 30 ppm\/deg C, Max 60 ppm\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e0.35 ms (PL = 500 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Cycle\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Class\u003c\/td\u003e\n\u003ctd\u003eATEX Zone 2, cULus Class 1 Div 2 \/ Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic ModuleBus Execution and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe AO810V2 transfers digital data across the backplane rail using optimized backplane bus communication velocity, achieving output refresh rates under 2 ms with a rapid 0.35 ms signal rise time. Firmware flash compatibility ensures synchronized operational execution with the cluster controller, while groupwise galvanic isolation decouples field ground loops from internal logic components. High 14-bit converter resolution enables accurate control over analog loops without introducing channel-to-channel noise interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What triggers an open-circuit warning on an active AO810V2 channel?\u003c\/p\u003e\n\u003cp\u003eA: An open-circuit channel fault triggers if the process power supply voltage drops below acceptable limits, or if loop current remains lower than the targeted setpoint when output demand exceeds 1 mA.\u003c\/p\u003e\n\u003cp\u003eQ: Can the AO810V2 module be hot-swapped during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The AO810V2 supports live hot-swapping on an active ModuleBus baseplate, enabling module replacement without taking down the controller rail or neighboring I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What is the main operational difference between the AO810V2 and the AO815 module?\u003c\/p\u003e\n\u003cp\u003eA: While both provide 8 unipolar analog output channels, the AO815 includes point-to-point HART pass-through communication, whereas the AO810V2 functions purely as a standard analog output card without HART capabilities.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the S800 terminal baseplate onto a standard 35 mm DIN rail, making sure that the integral grounding spring establishes firm, unpainted contact with the metal DIN rail frame. Align the backplane pins of the AO810V2 with the baseplate receptacle, applying steady pressure until the side locking tabs fully lock into position.\u003c\/p\u003e\n\u003cp\u003eConnect field instrumentation using twisted, shielded copper cables to reduce signal susceptibility to field electromagnetic interference. Terminate cable braid shields to the main panel grounding bus bar via low-impedance grounding clamps. Connect a clean external +24 VDC process supply, ensuring loop load resistances remain within the specified range (up to 500 Ohm on standard L1+ supply). Maintain a minimum 50 mm vertical airflow margin above and below the module housing for natural convection cooling up to +55 deg C ambient conditions.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53005030359352,"sku":"AO810 3BSE038415R1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/643._acac5f67-939f-43b3-bd1e-5afb80e8ce45.jpg?v=1790041672","url":"https:\/\/www.automodulexpert.com\/products\/8-channel-analog-output-module-abb-ao810v2-3bse038415r1","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}