{"product_id":"8201-hi-is-ge-analog-input-module-new-original-stock","title":"8201-HI-IS GE Analog Input Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-precision signal acquisition in distributed control system platforms, the \u003cstrong\u003eGE 8201-HI-IS\u003c\/strong\u003e (\u003cstrong\u003e8201-HI-IS\u003c\/strong\u003e Analog Input Module) provides direct physical and electrical measurement conversion. This hardware component processes field-side analog inputs, performing signal conditioning and digitization for integration into the control backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8201-HI-IS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eAnalog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE 8201-HI-IS\u003c\/strong\u003e integrates into the host backplane through defined communication protocols to ensure deterministic data transfer. Firmware synchronization is required to maintain bus communication velocity within the control network. Users must ensure that the rack backplane power supply can accommodate the module inrush current during initial power-up sequences. Compatibility with system-wide firmware flash updates ensures that the module maintains operational parity with current I\/O density scaling requirements across the network interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8201-HI-IS module support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: No, power must be disconnected from the specific backplane slot before inserting or removing the module to prevent electrical arcing or data bus corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is the signal path protected against external electrical interference?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the implementation of shielded twisted-pair cabling for field inputs, with cable shields grounded at a single, low-impedance termination point to minimize common-mode noise.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is seated firmly within the designated chassis slot, engaging the guide rails before applying pressure to the locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect signal leads to the terminal block using appropriate wire gauges (typically 0.5 mm to 1.5 mm). Ensure that no bare wire strands are exposed outside the terminal crimps to prevent short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the chassis backplane is securely connected to the cabinet ground bus. For installations prone to electromagnetic interference (EMI), ensure that the signal cable shields are continuous and terminated to the earth bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Measure the loop resistance before energizing the input. Ensure that the source voltage does not exceed the maximum input rating specified for the module to avoid damage to the internal isolation circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52519941210424,"sku":"8201-HI-IS","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/8201-HI-IS.jpg?v=1781679431","url":"https:\/\/www.automodulexpert.com\/products\/8201-hi-is-ge-analog-input-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}