This 8C-TDIL51 51306969-175 Digital Input Modules was manufactured by HONEYWELL, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
HONEYWELL
Part Number:
8C-TDIL51 51306969-175
Product type:
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Honeywell 8C-TDIL51 C300 Digital Input Module Baseplate

The Honeywell 8C-TDIL51, also cataloged as the 8C-TDIL51 Digital Input Module Baseplate (Part Number 51306969-175), operates as a dedicated hardware component for 32-channel discrete signal acquisition within Honeywell C300 and Experion PKS control systems. The assembly converts 24 VDC field signals from switches and sensors into isolated digital logic states for process control processing. System-to-field safety is maintained through optical isolation and galvanic isolation rated at 1000 VAC RMS, while integrated Open Wire Detection (OWD) diagnostics monitor field circuit integrity across a -40 deg C to +70 deg C operating temperature envelope.

Hardware Specifications

Parameter Specification
Model 8C-TDIL51 (PN: 51306969-175)
Brand Honeywell
Origin USA
Weight 0.5 kg
Dimensions 160 mm x 40 mm x 130 mm
Operating Temp -40 deg C to +70 deg C
Power Consumption Field supply: 18 to 30 VDC (User-supplied); Channel input current <= 10 mA
Input Channels 32 discrete digital input channels
Nominal Input Voltage 24 VDC (Operating range: 18 to 32 VDC)
ON / OFF Sensing Limits ON: >= 13 VDC or >= 3 mA; OFF: <= 5 VDC or <= 1.2 mA
Input Impedance >= 10 k-ohm (Typical 4.2 k-ohm baseline dependent on configuration)
Isolation Rating Optical isolation via IOM; 1000 VAC RMS galvanic isolation (system-to-field)
Signal Propagation Delay Absolute delay ~5 ms +- 20%
Environmental Limits Storage: -55 deg C to +85 deg C; Relative Humidity: 0% to 95% non-condensing
Shock and Vibration Shock: 15 g (11 ms half-sine); Vibration: 5 g RMS (10 to 500 Hz)
Diagnostics & Rating Open Wire Detection (OWD), channel status LEDs; IP20 cabinet enclosure rating
Mounting & Certifications Vertical installation on Series 8 IOTA baseplate; CE, UL, RoHS, EMC compliant

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The 8C-TDIL51 module interfaces with Series 8 I/O Termination Assemblies (IOTA) to maintain signal purity in high-density process environments. Integrated optical decoupling protects central C300 controllers against ground potential shifts and field-side electrical surges. Differential input threshold detection works alongside system-level filtering to evaluate discrete states without introducing crosstalk into adjacent analog 4-20 mA HART loops or Fieldbus communication segments residing on neighboring Series 8 baseplates.

Frequently Asked Questions

Q: How does the module handle hot-swapping under live field power conditions?

A: The 8C-TDIL51 module supports online insertion and removal (hot-swapping) on the Series 8 IOTA baseplate. Main system backplane communications remain active during module replacement, provided external 24 VDC field power isolation limits are observed to prevent electrical arcs across the connector pins.

Q: What mechanisms are used to detect field wiring faults on the digital input channels?

A: The module executes real-time Open Wire Detection (OWD) diagnostics alongside continuous channel status monitoring. When an open-circuit condition is detected on a monitored field contact loop, the IOM diagnostic register flags a fault bit to the C300 controller without interrupting the operation of unaffected channels.

Q: What installation requirements apply to the coated version of the module in humid or corrosive spaces?

A: Coated variants of the 8C-TDIL51 are chemically treated to withstand corrosive gases and relative humidity levels up to 95% non-condensing. However, cabinet installations must still maintain IP20 enclosure protection standards and adhere to vertical mounting profiles on the Series 8 baseplate to guarantee thermal convection flow.

Field Installation Guidelines

Mount the 8C-TDIL51 module vertically onto its dedicated Series 8 IOTA baseplate. Align the rear multi-pin connector with the baseplate socket and press firmly until the mechanical side latches lock into position. Secure the baseplate assembly to the cabinet enclosure ground using a low-impedance copper earth strap to establish proper functional grounding and EMC protection.

Route field wiring through low-voltage signal conduits separate from high-power AC distribution lines. When landing external 24 VDC supply cables, verify that polarity matches the terminal block assignments and that the supply remains within the specified 18 to 30 VDC operating envelope. Shielded field cables should be grounded at a single point on the cabinet entry gland plate to eliminate circulating ground loops across field switches.

Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.