{"product_id":"aai143-s00-s1-yokogawa-16-point-analog-input-module","title":"AAI143-S00 S1  Yokogawa 16-Point Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a core\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP and CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. It is designed to convert\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA DC field signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto high-resolution digital data for the system CPU. The module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust electrical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field wiring and internal system logic, protecting the control system from noise, surges, and ground potential differences.\u003c\/p\u003e\n\u003cp\u003eFeaturing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 16-point design\u003c\/strong\u003e, the AAI143-S00 S1 optimizes cabinet space within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e. Its fast conversion and update performance make it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-dynamic process loops\u003c\/strong\u003e, ensuring timely and accurate process variable acquisition.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 points, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω (powered on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e30 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Cycle\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003eMax. ±0.01% per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC: 230 mA \/ 24 V DC: 450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 × 130 × 30 mm (standard FIO footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eModule Integration and Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe AAI143-S00 S1 is designed for installation on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocal or remote I\/O baseplates\u003c\/strong\u003e. When deployed in a redundant system configuration, the module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot swapping\u003c\/strong\u003e, allowing replacement without interrupting ongoing process operations.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used for interfacing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure transmitters\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow meters\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elevel sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat operate on conventional analog current loops and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edo not require HART communication\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAI143-S00 S1 supply loop power to field transmitters?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esink-type analog input module\u003c\/strong\u003e. Field devices must be powered by an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternal 24 V DC loop supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor a dedicated power distribution module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the S00 and S50 suffixes?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix denotes the standard version without conformal coating, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically indicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-coated variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for corrosive or harsh environmental conditions.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51667072352568,"sku":"AAI143-S00 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAI143-S00_S11.jpg?v=1769565041","url":"https:\/\/www.automodulexpert.com\/products\/aai143-s00-s1-yokogawa-16-point-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}