{"product_id":"abb-3hac037084-001-dsqc697-devicenet-communication-board","title":"ABB 3HAC037084-001 DSQC697 DeviceNet Communication Board","description":"\u003ch2\u003eABB 3HAC037084-001 DSQC697 DeviceNet Communication Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for DeviceNet master and slave data exchange in ABB IRC5 robot controller systems, the \u003cstrong\u003eABB 3HAC037084-001\u003c\/strong\u003e (\u003cstrong\u003eDSQC697\u003c\/strong\u003e DeviceNet Communication Board) provides direct physical and electrical fieldbus execution across industrial automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDSQC697\u003c\/strong\u003e: Base hardware architecture designation for the DeviceNet interface board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3HAC037084-001\u003c\/strong\u003e: Primary part number identifying the active production release.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3HAC025779-001 \/ 3HAC12817-1\u003c\/strong\u003e: Legacy predecessor part numbers associated with earlier hardware revisions of the same functional platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSQC697\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3HAC037084-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 mm x 130 mm x 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eRefer to relevant ABB controller manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eController internal bus supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Master \/ Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller\u003c\/td\u003e\n\u003ctd\u003eABB IRC5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with backplane bus communication velocity metrics, ensuring deterministic network message scheduling across connected DeviceNet nodes. Firmware flash compatibility and RobotWare integration govern message handling speeds, preventing bus arbitration faults during concurrent multi-axis robot cell operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the communication board be inserted or removed while the controller main power is active?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be completely shut down before installing or extracting the board from the internal computer unit PCI slot to protect backplane logic circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What software prerequisites must be met to initialize the module?\u003c\/p\u003e\n\u003cp\u003eA: The controller requires RobotWare 5.13 or later along with the corresponding DeviceNet software option keys activated in the system configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How is bus termination handled on the physical network port?\u003c\/p\u003e\n\u003cp\u003eA: Standard 120-ohm terminating resistors must be installed at both extreme ends of the physical DeviceNet trunk line to suppress signal reflections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all electrical power sources feeding the controller cabinet before opening internal protective enclosures.\u003c\/li\u003e\n\u003cli\u003eGround yourself with an anti-static wrist strap connected to the controller chassis prior to handling the circuit board.\u003c\/li\u003e\n\u003cli\u003eInsert the board firmly into the designated internal computer-unit PCI slot, ensuring edge connectors align properly without bending pins.\u003c\/li\u003e\n\u003cli\u003eFasten all securing screws and verify that external DeviceNet drop cables maintain correct polarity and shield grounding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53199890841912,"sku":"DSQC697 3HAC037084-001","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/719..jpg?v=1791959225","url":"https:\/\/www.automodulexpert.com\/products\/abb-3hac037084-001-dsqc697-devicenet-communication-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}