{"product_id":"abb-ci868ak01-3bse092691r1-ac-800m-communication-interface","title":"ABB CI868AK01 3BSE092691R1 AC 800M Communication Interface","description":"\u003ch2\u003eABB CI868AK01 3BSE092691R1 AC 800M Communication Interface Package\u003c\/h2\u003e\n\u003cp\u003eConfigured for IEC 61850 Edition 2 substation protocol integration in System 800xA network architectures, the \u003cstrong\u003eABB CI868AK01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI868A\u003c\/strong\u003e IEC 61850 Communication Interface Package, provides direct physical and electrical execution of Manufacturing Message Specification (MMS) client and Generic Object-Oriented Substation Event (GOOSE) data frames. The assembly interfaces directly with the CEX-Bus backplane on ABB AC 800M controllers, combining power grid substation monitoring and industrial process control into a single execution environment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI868AK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Package Catalog Number\u003c\/td\u003e\n\u003ctd\u003e3BSE092691R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Communication Module\u003c\/td\u003e\n\u003ctd\u003eCI868A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Baseplate\u003c\/td\u003e\n\u003ctd\u003eTP867 (60 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 Communication Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e+24 VDC via CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e160 mA typical at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.8 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e59 x 185 x 127.5 mm (including base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g (including base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2 according to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarsh Environment Protection\u003c\/td\u003e\n\u003ctd\u003eISA 71.04 Class G3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eRJ45 female, 8-pin, 10\/100 Mbit\/s full duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Modules per Controller\u003c\/td\u003e\n\u003ctd\u003e12 units on CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity Limits\u003c\/td\u003e\n\u003ctd\u003e120 GOOSE IEDs and 40 MMS IEDs per CI868A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware\/Software Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA version 6.0.3.3, 6.1.1, and subsequent versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCEX-Bus Deterministic Network Integration \u0026amp; Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe CI868A module utilizes onboard logic to manage real-time communication task schedules over the CEX-Bus backplane, maintaining deterministic data handshakes without overburdening the primary AC 800M processor CPU. Dedicated internal DC\/DC converter circuitry converts incoming +24 VDC system power into isolated board-level operating voltages. Network communication relies on high-speed Ethernet drivers supporting 10\/100 Mbit\/s transmission speeds with channel isolation to shield internal logic against common-mode electrical noise. Hardware code locks integrated into the TP867 baseplate physically prevent incorrect module insertion during field maintenance. Furthermore, the unit supports hot-swap replacement under live backplane power, eliminating system shutdowns while maintaining protocol link state consistency across the System 800xA control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CI868AK01 module be hot-swapped while the AC 800M controller remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CI868A communication module supports online hot-swapping on the TP867 baseplate. Furthermore, field technicians must ensure that substituting the module does not disrupt critical GOOSE network subscriber paths before unlatching the hardware from the CEX-Bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TP867 baseplate prevent accidental insertion of wrong module types?\u003c\/p\u003e\n\u003cp\u003eA: The TP867 baseplate incorporates a mechanical code lock system. Furthermore, technicians must align the physical keying mechanisms on both baseplate and module prior to insertion, ensuring that incompatible I\/O or communication hardware cannot make electrical contact with the CEX-Bus power and signal rails.\u003c\/p\u003e\n\u003cp\u003eQ: Is network redundancy supported directly on the single CI868A Ethernet port?\u003c\/p\u003e\n\u003cp\u003eA: No, the CI868A hardware interface does not support dual-port network redundancy on a single module. Furthermore, fault-tolerant network topology requires installing duplicate CI868A modules across separate CEX-Bus positions within the same AC 800M controller framework.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mechanical Mounting:\u003c\/strong\u003e Latch the TP867 baseplate securely onto the standard 35 mm DIN rail prior to sliding the assembly onto the CEX-Bus backplane connector. Ensure all mechanical locking tabs click into position to maintain grounding continuity across the backplane structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding and Cable Routing:\u003c\/strong\u003e Fasten STP (Shielded Twisted Pair) Cat 5e or Cat 6 Ethernet cables using standard RJ45 connectors. Connect all cable shields to the main cabinet functional ground bus bar using low-impedance grounding clamps to mitigate high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrain Wire and Ground Bus Termination:\u003c\/strong\u003e Route the backplane ground connection directly to the main protective earth (PE) bus. Maintain cable bends above minimum bend radius limits (typically 4x outer cable diameter) and segregate network Ethernet lines from high-voltage AC motor wires by at least 200 mm within cabinet wire ducts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53048985682232,"sku":"CI868AK01 3BSE092691R1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/597_32f08233-ec9f-4366-8dc1-0b2d1e66a4a0.jpg?v=1790578600","url":"https:\/\/www.automodulexpert.com\/products\/abb-ci868ak01-3bse092691r1-ac-800m-communication-interface","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}