{"product_id":"abb-ci869k01-3bse049110r1-ac-800m-af-100-module","title":"ABB CI869K01 3BSE049110R1 AC 800M AF 100 Module","description":"\u003ch2\u003eABB CI869K01 3BSE049110R1 AF 100 Communication Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI869K01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3BSE049110R1\u003c\/strong\u003e Communication Interface Kit, operates as a dedicated hardware component for AF 100 network communication within ABB System 800xA and AC 800M platforms. The module interfaces an AC 800M controller to an Advant Fieldbus 100 network, executing real-time data exchanges over twisted pair or fiber optic media to integrate AC 800M control loops with compatible Advant Master process-control equipment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI869K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e59 mm x 186 mm x 127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane supply via TP869 baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eAdvant Fieldbus 100 (AF 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Media\u003c\/td\u003e\n\u003ctd\u003eTwisted pair or Fiber Optic (via modems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB AC 800M \/ System 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Kit Components\u003c\/td\u003e\n\u003ctd\u003eCI869 Module, TP869 Baseplate (60 mm width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Backplane Bus \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates backplane bus communication velocity licenses to drive deterministic EtherNet\/IP and AF 100 network performance across System 800xA topologies. Designed for scalable I\/O density architectures, the interface handles process telemetries and execution loops without causing bus latency. Integrated flash memory preserves firmware flash compatibility, facilitating online logic updates and synchronized hardware handshakes across AC 800M controller configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical items are included in the CI869K01 interface kit assembly? A: The kit includes the CI869 Communication Interface module and the TP869 terminal baseplate (60 mm footprint width). The baseplate provides mechanical mounting and electrical backplane connections directly to the AC 800M controller stack.\u003c\/p\u003e\n\u003cp\u003eQ: How does the interface handle media transition from twisted-pair wiring to optical fiber networks? A: The CI869 module outputs standard twisted-pair signals on the AF 100 trunk. To extend communication distances or eliminate noise, external fiber optic modems attach directly to the media terminal lines without altering the protocol structure.\u003c\/p\u003e\n\u003cp\u003eQ: What is the procedure for hot-swapping the CI869 module on an active TP869 baseplate? A: Unlatch the module retention mechanism and pull the CI869 straight off the TP869 baseplate. The baseplate maintains physical backplane continuity for adjacent communication modules, allowing hot-swap replacement without interrupting power or bus signals across the main controller chassis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen mounting or replacing the CI869K01 communication interface inside an automation cabinet, observe these primary installation practices:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting and Mechanical Engagement\u003c\/strong\u003e: Snap the TP869 baseplate onto the DIN rail adjacent to the AC 800M processor unit. Slide the baseplate horizontally to latch the side backplane bus connectors firmly into the neighboring slot. Seat the CI869 module onto the TP869 baseplate until top and bottom lock mechanisms click completely into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Wiring and Physical Layout\u003c\/strong\u003e: Connect the AF 100 twisted-pair communication cable to the designated screw terminal connectors on the baseplate. Route low-voltage communication lines through dedicated cable wireways kept separate from high-voltage AC power distribution leads to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Continuity\u003c\/strong\u003e: Connect the cable shield of the AF 100 network directly to the primary cabinet ground rail using a low-impedance ground clip. Ensure all terminal screws on the signal block are torqued according to panel specs, and confirm that conduit fittings maintain a minimum of 5 full threads of engagement to preserve enclosure ingress protection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53018290848056,"sku":"CI869K01 3BSE049110R1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/635_33413303-46d6-4713-9f84-f3b8f4a3af39.jpg?v=1790220271","url":"https:\/\/www.automodulexpert.com\/products\/abb-ci869k01-3bse049110r1-ac-800m-af-100-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}