{"product_id":"abb-dsqc652-irc5-digital-i-o-circuit-board","title":"ABB DSQC652 IRC5 Digital I\/O Circuit Board","description":"\u003ch2\u003eABB DSQC652 Digital I\/O Circuit Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3HAC025917-001\/00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSQC652\u003c\/strong\u003e Digital I\/O Circuit Board, operates as a dedicated hardware component for digital signal acquisition and control output execution within ABB IRC5 robot controller networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSQC652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3HAC025917-001\/00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Global Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e155.5 mm x 98.5 mm x 41.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 W (excluding external load draws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 channels, 24 V DC rated (15–35 V DC logic 1, -35 to 5 V DC logic 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 channels, 24 V DC rated, 500 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection, current limiting, and thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDeviceNet (automatic baud-rate detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeviceNet Communication \u0026amp; I\/O Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the robot controller backplane via a standardized DeviceNet protocol layer supporting polled, Change-of-State (COS), and cyclic transmission modes. Built-in automatic baud-rate detection synchronizes data exchange across distributed nodes, maintaining low network latency for high-speed robotic cell synchronization. System monitoring is maintained through onboard board\/network status LEDs and individual channel status indicators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DSQC652 module be hot-swapped while the IRC5 controller is powered on?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping is restricted to prevent backplane bus corruption and transient voltage spikes on the 24 V DC power rails. Power must be fully isolated before module extraction or insertion.\u003c\/p\u003e\n\u003cp\u003eQ: What protections are integrated into the digital output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel features built-in short-circuit protection, current-limiting circuitry, and thermal overload protection to safeguard against external wiring faults exceeding the 500 mA rating.\u003c\/p\u003e\n\u003cp\u003eQ: How is communication fault status diagnosed on the module?\u003c\/p\u003e\n\u003cp\u003eA: Board and network status LEDs provide real-time visual diagnostics for node health, bus power validation, and packet transmission errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting:\u003c\/strong\u003e Install the unit securely inside the designated cabinet slots of the ABB IRC5 controller or certified external I\/O housing using proper mechanical fasteners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Terminate DeviceNet communication cable shields to the designated functional earth (FE) terminal plate to suppress electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Ensure the external 24 V DC supply meets the regulated 19–35 V DC operating window before energizing the I\/O bus rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Verification:\u003c\/strong\u003e Verify polarity on all 16 digital input and output screw terminal blocks prior to system startup to prevent reverse-voltage damage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53253531763000,"sku":"DSQC652 3HAC025917-001\/00","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/729._a982184d-ebb2-47ec-8ce0-03d1e1662280.jpg?v=1792026044","url":"https:\/\/www.automodulexpert.com\/products\/abb-dsqc652-irc5-digital-i-o-circuit-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}