{"product_id":"abb-ret670-1mrk002816-ac-relion-transformer-relay","title":"ABB RET670 1MRK002816-AC Relion Transformer Relay","description":"\u003ch2\u003eABB RET670 1MRK002816-AC Relion 670 Series Transformer Protection and Control IED\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB RET670 1MRK002816-AC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eRET670\u003c\/strong\u003e Transformer Protection and Control IED, operates as a dedicated hardware component for multi-winding power transformer differential protection and switchyard bay management within Relion 670 substation automation networks. The numerical unit processes up to 6 current transformer (CT) inputs and voltage transformer (VT) vectors across wideband operating frequencies, executing fast multi-zone differential algorithms, restricted earth-fault logic, and complex breaker trip management for single, dual, or multi-breaker configurations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrdering Part Number \/ Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePlatform Series\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Focus \u0026amp; Breaker Logic Scope\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRET670 1MRK002816-AC\u003c\/td\u003e\n\u003ctd\u003eRelion 670 Series\u003c\/td\u003e\n\u003ctd\u003eStandard ANSI A(AB)\/B(BB) configuration, supporting up to 6 CT inputs, wideband frequency operation, and multi-breaker switchyard control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRET670 1MRK002816-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack chassis width: 442 mm, Height: 6U (266 mm), Depth: 220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower supply input load: \u0026lt;50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Voltage\u003c\/td\u003e\n\u003ctd\u003eTypically 110 kV and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003eSupports up to 6 Current Transformer (CT) inputs (1 A \/ 5 A nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Configuration\u003c\/td\u003e\n\u003ctd\u003eANSI A(AB)\/B(BB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Logic\u003c\/td\u003e\n\u003ctd\u003eTransformer differential, restricted earth-fault, negative sequence, phase overcurrent, thermal overload, overexcitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003eWideband operation for power system disturbances and generator ramp-up\/down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineering Software\u003c\/td\u003e\n\u003ctd\u003eABB PCM600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Substation Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages a high-speed backplane bus to deliver real-time data streaming between high-density analog acquisition boards and main processing units. Deterministic backplane communications guarantee sub-millisecond data transfer rates for high-speed current transformer vector processing. Ethernet communication modules integrate natively with IEC 61850 substation bus architectures, executing GOOSE trip signals for cross-bay interlocking. Firmware updates and scheme parametrization process through the front panel optical port or rear RJ45 Ethernet connection using PCM600 software, performing automated firmware flash compatibility verification to safeguard non-volatile settings during updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the RET670 handle wideband frequency variations during generator ramp-up or system disturbances?\u003c\/p\u003e\n\u003cp\u003eA: The numerical processing engine employs dynamic adaptive sampling algorithms that track fundamental frequency shifts across wide operating ranges. This ensures differential, overcurrent, and negative sequence protection zones retain precise calibration and fast trip response during turbine start-up or major grid frequency excursions.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are required when servicing or replacing analog CT input modules?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must short-circuit all current transformer secondary loops at external test terminal blocks prior to disconnecting rear terminal blocks or extracting cards. Disconnecting active CT circuits under load creates high-voltage inductive spikes that risk internal hardware damage and physical arc hazards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the 6U 19-inch rack enclosure flush within a switchgear relay panel using M6 mounting hardware. Provide a minimum vertical clearance of 100 mm above and below the chassis to ensure unhindered thermal convection across the passive cooling fins.\u003c\/p\u003e\n\u003cp\u003eEstablish a low-impedance protective earth link by routing a heavy-duty green\/yellow stranded copper grounding cable (minimum cross-sectional area of 6.0 mm2) from the primary ground post on the rear aluminum chassis directly to the substation panel copper earth bar. Route CT\/VT analog secondary leads, binary input wires, and station bus Ethernet cables in separate grounded metallic wireways. Ensure cable shielding braids ground at a single panel entry gland plate to suppress electromagnetic interference and prevent circulating earth currents. Torque rear ground connections to 2.0 N-m, ensuring at least 5 full threads of engagement.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53118684463416,"sku":"RET670 1MRK002816-AC","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/701..jpg?v=1791595858","url":"https:\/\/www.automodulexpert.com\/products\/abb-ret670-1mrk002816-ac-relion-transformer-relay","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}