{"product_id":"adv151-p50-atd5a-00-s1-yokogawa-digital-input-module","title":"ADV151-P50 \/ ATD5A-00 S1 Yokogawa Digital Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-P50 \/ ATD5A-00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-channel high-density digital input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. It interfaces with discrete field devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, proximity sensors, and relay contacts\u003c\/strong\u003e. Utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field network I\/O) architecture\u003c\/strong\u003e, it provides high-speed data acquisition with robust signal isolation for seamless DCS integration.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP50 functional set\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated pushbutton\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor local diagnostic input while omitting a front-panel LED display for a compact design. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00 adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-cable connectivity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia KS multi-core cables, simplifying cabinet wiring. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS1 style code\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the original hardware revision, ideal for like-for-like replacements in existing systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV151-P50 \/ ATD5A-00 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Sink\/Source compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput ON Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.0 – 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput OFF Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.1 mA ±20% per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (signal-to-system, 1 min), 500 V AC (between commons, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels per common return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATD5A-00 (MIL-connector KS cable interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyle Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eFunctional Code Breakdown\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Integrated pushbutton for manual testing or local diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix 5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Standard industrial version without LED display, non-explosion proof.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuffix 0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Basic hardware for standard environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdapter \/ATD5A-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Converts module pins to a KS cable MIL-connector interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlant Monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Status tracking of valves, limit switches, and interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMachine Feedback\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Monitoring \"Run\/Stop\" and \"Fault\" signals from MCCs (pumps, fans).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSequence Logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Providing discrete triggers for automated batch or process sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the ATD5A-00 adapter?\u003c\/strong\u003e\u003cbr\u003eA: It enables single-cable “plug-and-play” connectivity to a terminal board, avoiding 32 individual wire connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle 12 V DC inputs?\u003c\/strong\u003e\u003cbr\u003eA: No. The module requires ≥ 18 V DC for an \"ON\" state; 12 V signals will read as \"OFF.\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the S1 style code compatible with S2 systems?\u003c\/strong\u003e\u003cbr\u003eA: Generally yes. Modules are backward compatible, but for dual-redundant configurations, it is recommended to match style codes.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51687965655352,"sku":"ADV151-P50 \/ ATD5A-00 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV151-E10.jpg?v=1770088644","url":"https:\/\/www.automodulexpert.com\/products\/adv151-p50-atd5a-00-s1-yokogawa-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}