{"product_id":"adv551-32do-yokogawa-digital-output-module","title":"ADV551-32DO Yokogawa Digital Output Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV551\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-channel high-density digital output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. Utilizing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent-sink (transistor contact) architecture\u003c\/strong\u003e, it serves as the primary interface for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-side actuators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esolenoid valves, interposing relays, and status indicators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field network I\/O) architecture\u003c\/strong\u003e, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed command execution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust system protection\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 kV AC isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field signals and system logic, the ADV551 maintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeven in electrically noisy industrial environments. Its slim form factor and high-density design reduce the footprint of distributed I\/O racks, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries, power plants, chemical processing, and other mission-critical installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output (Transistor Contact, Current Sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Supply Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 – 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3 ms (status output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports Pulse Width Output \u0026amp; Time-Proportional Control (P-suffix models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC signal-to-system; 16-channel negative common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 channels in a single FIO slot reduce node unit and cabinet requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Sink Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActs as a switch to the negative side; external 24 V DC supply drives the field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime-Proportional Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eP-suffix modules can generate duty-cycle outputs for heating loops, dosing pumps, or similar applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV AC separation ensures protection against electrical surges and field-side disturbances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefinery Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperating arrays of solenoid valves for process routing and manifold management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDriving heating elements or solid-state relays with time-proportional outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm \u0026amp; Status Signaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlling high-density stacks of lamps or indicators in control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the ADV551 an input or output module?\u003c\/strong\u003e\u003cbr\u003eA: The ADV551 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estrictly a digital output module\u003c\/strong\u003e. For 24 V DC digital inputs, use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive AC loads?\u003c\/strong\u003e\u003cbr\u003eA: No, it is rated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC only\u003c\/strong\u003e. To control AC devices, use an interposing relay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of cabling is used for high-density connections?\u003c\/strong\u003e\u003cbr\u003eA: Typically, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAKB331 series multi-core cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used with an interface adapter, or a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure-clamp terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be used for direct wiring.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51688109637944,"sku":"ADV551-32DO","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV551-32DO1.jpg?v=1770083113","url":"https:\/\/www.automodulexpert.com\/products\/adv551-32do-yokogawa-digital-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}