{"product_id":"adv551-p00-d5a00-yokogawa-digital-output-module","title":"ADV551-P00\/D5A00 Yokogawa Digital Output Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV551-P00\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density discrete output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP \/ CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 isolated current-sink output channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor controlling field-side devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epilot relays, solenoids, and indicator lamps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00 KS Cable Interface Adapter (\/D5A00)\u003c\/strong\u003e, enabling all channels to connect via a single high-density KS cable to external terminal boards. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP00 basic suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edenotes standard functionality with pulse-width support, and the module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel common grouping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor isolation and fault protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eADV551-P00\/D5A00 (Current Sink, KS Cable Adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eSink-type transistor (NPN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e20.4 – 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Leakage\u003c\/td\u003e\n\u003ctd\u003e0.1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e2 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Output Response\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Function Range\u003c\/td\u003e\n\u003ctd\u003e8 ms – 7,200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms (≤ 1 ms transition delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (System to Output)\u003c\/td\u003e\n\u003ctd\u003e2,000 V AC, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e500 V AC (Common minus every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Draw\u003c\/td\u003e\n\u003ctd\u003e700 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Draw\u003c\/td\u003e\n\u003ctd\u003e60 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003eATD5A-00 KS Cable Interface pre-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 channels in a single slot, reducing cabinet footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse-Width Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports configurable ON-time for time-proportional control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKS Cable Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\/D5A00 adapter consolidates all channels into a single KS cable, simplifying installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrouped Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo 16-channel commons prevent faults in one group from affecting the other.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 3 ms output latency suitable for rapid switching applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \/D5A00 adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConverts the module’s high-density pins into a single KS cable interface, reducing wiring complexity, space, and commissioning labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for source-type (PNP) wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. The ADV551-P00\/D5A00 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent-sink only\u003c\/strong\u003e. Loads must connect between positive DC power and the module output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 16-channel common isolation protect the system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEach group of 16 outputs has its own common minus. Electrical faults or ground loops in one group do not affect the other group or the DCS logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51683660136760,"sku":"ADV551-P00\/D5A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV151-P03D5A00.jpg?v=1770001408","url":"https:\/\/www.automodulexpert.com\/products\/adv551-p00-d5a00-yokogawa-digital-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}