{"product_id":"afs40s-afs40d-centum-vp-yokogawa-ethernet-communication-module","title":"AFS40S\/AFS40D CENTUM VP Yokogawa Ethernet Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AFS40S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFS40D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet Communication Modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000 Distributed Control Systems (DCS)\u003c\/strong\u003e. These modules establish the vital data link between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Unit (FCU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand external subsystems, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLCs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esupervisory computers\u003c\/strong\u003e, and specialized plant networks. By offloading communication tasks from the main control processor, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFS40 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic control performance and robust data throughput. These units are supplied as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock, guaranteeing maximum uptime for critical processes.\u003c\/p\u003e\n\u003ch4\u003ePart Number Breakdown: AFS40S \/ AFS40D\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAFS40S\u003c\/strong\u003e: Single Ethernet Communication Module for standard, non-redundant network paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAFS40D\u003c\/strong\u003e: Duplexed Ethernet Communication Module designed for high-availability configurations with redundant pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Fast Ethernet (100BASE-TX \/ 10BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, UDP, and standard industrial communication protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecialized Communication Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm (H) x 100 mm (D) x 30 mm (W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CS 3000 Field Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Network Isolation\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFS40S\/D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules feature internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e, protecting the FCU backplane from electrical noise and ground loops, which minimizes the risk of hardware failure during electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Integration\u003c\/strong\u003e: With a slim\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprofile, these modules take up minimal space, enabling engineers to deploy multiple communication paths within a single rack and support complex multi-network configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduced CPU Overhead\u003c\/strong\u003e: The onboard dedicated processor manages protocol stack operations, allowing the main FCU processor to remain focused on real-time control logic, thus preventing network traffic spikes from destabilizing critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance\u003c\/strong\u003e: These\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are fully compatible with the latest firmware. Onboard LED indicators show link integrity and data activity, allowing for quick troubleshooting without the need for specialized diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eCan the AFS40D operate in a non-redundant slot?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFS40D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan function in a single-slot configuration. However, duplexed failover benefits are only realized when using a matching pair in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant-ready backplane\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eDoes this module support fiber optic connections?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFS40S\/D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRJ45 interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor copper cabling. If your setup requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiber optics\u003c\/strong\u003e, you can use an external\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedia converter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor opt for a specific fiber-interface model.\u003c\/p\u003e\n\u003ch4\u003eHow does the unit handle high-traffic environments?\u003c\/h4\u003e\n\u003cp\u003eThe module's dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication buffer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles incoming and outgoing packets independently of the control cycle, preventing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"packet storms\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom disrupting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-critical PID loops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eIs this a genuine original part?\u003c\/h4\u003e\n\u003cp\u003eYes, we only sell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa products\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein their\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efactory-sealed packaging\u003c\/strong\u003e, complete with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal serial numbers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor tracking and warranty verification.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":52007380615480,"sku":"AFS40S\/AFS40D","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAB841-S00S22.jpg?v=1773969859","url":"https:\/\/www.automodulexpert.com\/products\/afs40s-afs40d-centum-vp-yokogawa-ethernet-communication-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}