{"product_id":"ai830a-3bse040662r1-abb-s800-i-o-analog-input-modules","title":"S800 I\/O Analog Input Modules ABB AI830A 3BSE040662R1","description":"\u003ch2\u003eABB CI867A 3BSE092689R1\u003c\/h2\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI867A 3BSE092689R1\u003c\/strong\u003e is a \u003cstrong\u003eMODBUS TCP Communication Interface\u003c\/strong\u003e for the ABB \u003cstrong\u003eAC 800M controller\u003c\/strong\u003e and System 800xA automation platform. It provides Ethernet-based communication between an AC 800M controller and external devices or systems using the \u003cstrong\u003eMODBUS TCP protocol\u003c\/strong\u003e. The CI867A supports both \u003cstrong\u003eMODBUS TCP Master and Slave\u003c\/strong\u003e functionality and is designed for industrial process control and DCS applications.\u003c\/p\u003e\n\u003cp\u003eThe CI867A is a \u003cstrong\u003esingle-channel Ethernet interface\u003c\/strong\u003e with a 10\/100 Mbit\/s communication port. It supports \u003cstrong\u003emodule redundancy and hot swapping\u003c\/strong\u003e, making it suitable for applications requiring high system availability. Up to \u003cstrong\u003e70 slave units and 8 master units\u003c\/strong\u003e can be used with one CI867A. The module connects to the AC 800M controller through the \u003cstrong\u003eCEX-Bus\u003c\/strong\u003e and uses an \u003cstrong\u003e8-pin RJ-45 female connector\u003c\/strong\u003e for Ethernet communication.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCI867A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE092689R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMODBUS TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaster \/ Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Ethernet Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCh1, full duplex, up to 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHot Swap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Units on CEX-Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Slave Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 per CI867A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Master Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 per CI867A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCEX-Bus Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+24 V DC via CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical 24 V Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsed with HI Controller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA 6.0.3.3, 6.1.1 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +55 °C (+32 to +131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−40 to +70 °C (−40 to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG3, according to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 g including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Location Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecULus Class 1, Zone 2; AEx nA IIC T4; Ex nA IIC T4 Gc X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarine Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV, LR, CCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS \/ WEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eABB's official documentation confirms that \u003cstrong\u003e3BSE092689R1\u003c\/strong\u003e is the article number for CI867A, with \u003cstrong\u003eMODBUS TCP\u003c\/strong\u003e, one Ethernet channel, 10\/100 Mbit\/s transmission, module redundancy, hot-swap capability, and support for HI Controllers.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMODBUS TCP Master and Slave\u003c\/strong\u003e functionality\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSingle Ethernet channel\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\/100 Mbit\/s\u003c\/strong\u003e Ethernet communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule redundancy\u003c\/strong\u003e for high availability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-swappable\u003c\/strong\u003e design\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003e70 slave units and 8 master units\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRJ-45 8-pin\u003c\/strong\u003e Ethernet connection\u003c\/li\u003e\n\u003cli\u003eCEX-Bus interface for \u003cstrong\u003eAC 800M\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eABB System 800xA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eindustrial automation, DCS, process control, and third-party device integration\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53059099885880,"sku":"CI867A 3BSE092689R1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/641_23bcd801-f5f0-4aa0-8156-74e0d3f81e5a.jpg?v=1790749162","url":"https:\/\/www.automodulexpert.com\/products\/ai830a-3bse040662r1-abb-s800-i-o-analog-input-modules","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}