Allen-Bradley 1769-OF8C CompactLogix Analog Current Output Module
Configured for precise signal generation in process control loops, the Allen-Bradley 1769-OF8C (1769-OF8C Analog Output Module) provides direct physical/electrical execution across CompactLogix and MicroLogix 1500 system platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 1769-OF8C |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA / Multiple |
| Weight | 0.26 kg (0.56 lbs) |
| Dimensions | 35 mm x 118 mm x 87 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 2.69 W max heat dissipation |
| Bus Current Draw | 145 mA at 5.1 VDC, 180 mA at 24 VDC |
| Number of Outputs | 8 single-ended current channels |
| Output Current Ranges | 0 to 20 mA, 4 to 20 mA |
| Full Scale Range | 0 to 21 mA, 3.2 to 21 mA |
| Conversion Rate | <= 5 ms (all channels) |
| Resolution | 16-bit (0.323 uA/bit) |
| Load Impedance | Resistive 0 to 500 Ohms, Inductive <= 0.1 mH |
| Isolation Voltage | 500 VAC or 710 VDC for 1 min (30 V AC/DC continuous) |
| Slot Width | 1 Slot |
| Wire Size | 22 to 14 AWG solid, 22 to 16 AWG stranded |
Backplane Bus & Deterministic Network Execution
The module transfers command values across the 1769 Compact I/O backplane bus communication velocity framework, establishing deterministic signal updating for output channels. Internal logic maps controller registers directly to the 16-bit digital-to-analog converter, executing simultaneous signal updates across all 8 single-ended channels within 5 ms. System firmware flash compatibility guarantees real-time output synchronization while enforcing channel-to-backplane isolation under varying load conditions. The onboard drive circuits maintain output loop accuracy across backplane backplane spans during active I/O density scaling, continuously monitoring for open-circuit and short-circuit fault states.
Frequently Asked Questions
Q: What power supply distance rating restrictions apply when placing this module on a 1769 backplane?
A: You must mount the module within 8 slot locations of the 1769 system power supply. Exceeding an 8-module power supply distance rating causes backplane voltage drops that can degrade current drive performance or disrupt module communications.
Q: What external power supply requirements are necessary to operate the analog output circuits?
A: The module requires an external Class 2 24 VDC power supply delivering 20.4 to 26.4 VDC. This external field power feeds the current loops while drawing 180 mA under full load conditions.
Field Installation Guidelines
Mount the unit on an IEC standard DIN rail or attach it securely to an enclosure panel backplate using M4 screws. Confirm that the ambient operating temperature inside the cabinet stays within 0 to 60 deg C during operation.
Connect field wiring using copper conductors rated for 90 deg C. Secure solid (22 to 14 AWG) or stranded (22 to 16 AWG) wires into the terminal block screws, tightening to a torque specification of 0.68 N m (6 lb in). Ensure load loop resistance stays under 500 Ohms per channel to maintain proper loop regulation.
Route current loop cables in dedicated raceways separated from high-voltage AC feeds and variable frequency drive output cables. Connect cable shielding to a single earth ground point on the cabinet chassis to shield analog signals from electromagnetic noise.
| Quick Quotes | Receive price & availability FAST from our dedicated customer service team. |
|---|---|
| Delivery | Expedited, Freight, And International Shipping Available. |
| Condition | 100% New with Original Package |
| Payment | We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL. |
| Shipping Port | ShangHai, Xiamen |
| Warranty | 12 Months |
| Q: Is Our Pricing Competitive? |
| A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends. |
| Q: What Is the Warranty Period? |
| A: All our new and original products come with a standard one-year warranty. |
| Q: What Payment Methods Do We Accept? |
| A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them. |
| Q: What Shipping Methods Do We Use? |
| A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders. |
| Q: What Is Our Delivery Time? |
| A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule. |
| Q: How Do We Package the Goods? |
| A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes. |
| Q: How Can Customers Contact Us and Request a Quote? |
| A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote. |