{"product_id":"allen-bradley-1769-ov16-compact-i-o-16-point-sinking-output-module","title":"Allen-Bradley 1769-OV16 Compact I\/O 16 Point Sinking Output Module","description":"\u003ch2\u003eAllen-Bradley 1769-OV16 Compact I\/O Digital Sinking Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-OV16\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1769-OV16\u003c\/strong\u003e Compact I\/O Digital Output Module, operates as a dedicated hardware component for solid-state discrete load switching within CompactLogix and MicroLogix 1500 systems. The unit routes 24 VDC sinking signals across 16 channels organized into a single output group, interfacing directly with field actuators, relays, and solenoids while drawing 200 mA backplane current at 5 VDC.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-OV16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 kg (1.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e118 x 35 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA at 5 VDC (3.5 W heat dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC Solid-State Sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16 outputs (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A at 60 deg C (1.0 A at 30 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Module\u003c\/td\u003e\n\u003ctd\u003e4.0 A at 60 deg C (8.0 A at 30 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A for 10 ms (repeatable every 2 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time\u003c\/td\u003e\n\u003ctd\u003eON: 0.1 ms, OFF: 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cp\u003eThe high-density output card leverages backplane bus communication velocity to process rapid discrete switching logic directly from the system processor. Real-time signal transfer across EtherNet\/IP deterministic networks enables sub-millisecond execution times without introducing bus latencies. Continuous firmware flash compatibility checks maintain operational alignment between field load states, I\/O mapping tables, and central control routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 1769-OV16 output module be removed or inserted into the CompactLogix assembly while backplane power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No, the 1769-OV16 module does not support Removal and Insertion Under Power (RIUP). Attempting to hot-swap this module while the backplane power supply is energized causes system bus errors and risks permanent electrical damage to the connector pins.\u003c\/p\u003e\n\u003cp\u003eQ: What size wiring should technicians use when connecting 24 VDC field loads to the 1769-OV16 terminal block?\u003c\/p\u003e\n\u003cp\u003eA: Install solid or stranded copper wire rated for 90 deg C within the range of 22 to 14 AWG. Tighten field terminal screws securely to ensure stable contact resistance across all 16 output channels under continuous operating current limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a 35 mm DIN rail or secure it to an enclosure mounting plate using the integrated retractable feet. Maintain a minimum clearance of 50 mm above and below the module to promote convection cooling and manage internal heat dissipation. Wire field loads using 22 to 14 AWG copper conductors, separating 24 VDC output lines from high-voltage AC power wiring and motor drive outputs. Connect external load supply power directly across the designated VDC and DC NEUT terminals on the removable terminal block before applying system power.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52921241469240,"sku":"1769-OV16","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/333..jpg?v=1788833238","url":"https:\/\/www.automodulexpert.com\/products\/allen-bradley-1769-ov16-compact-i-o-16-point-sinking-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}